Content available remote Insulating properties of optical fiber current sensor with external conversion
EN
In the article are presented results of investigations on insulating properties of an optical fiber current sensor with external conversion (OFCS-EC). Its design and characterization were presented in our papers [1, 2]. The aim of studies presented in this paper is to verify good isolation properties and correct operation of the presented sensor exposed to very high voltage. Sensor’s response was tested at alternating voltage of magnitude up to 30 kV. Our tests fully confirmed very good isolation properties of the investigated OFCS-EC.
PL
W pracy przedstawiono badania nad własnościami izolacyjnymi światłowodowego czujnika prądu z przetwarzaniem zewnętrznym (OFCS-EC). Czujnik został wcześniej zaprojektowany i przebadany [1, 2]. Celem prezentowanych w artykule badań jest weryfikacja dobrych własności izolacyjnych czujnika oraz poprawności pracy czujnika pod wysokim napięciem. Przetestowano odpowiedź czujnika przy napięciu przemiennym do 30 kV. Wykonane testy w pełni potwierdziły bardzo dobre własności izolacyjne czujnika OFCS-EC.
2
Content available remote International comparison of AC current ratio standards
EN
This paper presents the results of an international comparison of AC current ratio standards between the Czech Metrology Institute (CMI) and the Georgian National Agency for Standards, Technical Regulation and Metrology (GEOSTM). Ratio errors and phase displacements were measured in the range (5 up to 2 000) A at 50 Hz mains frequency. Two GEOSTM 2-stage standard current transformers were used as transfer standards. These transformers were designed and developed at GEOSTM Tbilisi, Georgia.
PL
W artykule przedstawiono międzynarodowe porównanie wzorców stosunku prądów AC wykonanych przez Czeski Instytut Metrologii CMI i Gruzińską Narodową Agencję Wzorców, Norm i Metrologii GEOSTIM. Zbadano błąd stosunku oraz fazy w zakresie 5 - 2000 A przy częstotliwości 50 Hz. Wykorzystano wzorce Instytutu gruzińskiego. Transformatory zostały opracowane w GEOSTM.