Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  inkluzyjne membrany polimerowe
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The separation of iron(IIl) from chloride aqueous solutions containing Mn(II), Ni(II), Co(II) and Cu(ll) by solvent extraction and transport through polymer inclusion membranes (PIMs) processes was studied. Tributyl phosphate (TBP) was used as the extractant/ion carrier. Extraction of Fe(lII) increased with increasing of extractant concentration in the organic phase. The selective transport of Fe(lll) from aqueous chloride source phase through PIM containing cellulose triacatate (CTA) as the support, ο-nitrophenyl octyl ether (ONPOE) as the plasticizer and TBP as the ion carrier has been studied. The influence of the ion carrier and plasticizer concentration on the transport metal ions was investigated. The results show that Fe(III) can be separated very effectively from others metal ions. The atomic force microscopy (AFM) was used to obtain images of the pores in cellulose triacetate membranes containing a plasticizer.
PL
W pracy przedstawiono wyniki badań selektywnego wydzielania Jonów Fe(III) z wodnego roztworu chlorkowego zawierającego jony Mn(II), Ni(II), Cu(II) i Co(II) w procesie ekstrakcji cieczowej i transportu przez polimerowe membrany inkluzyjne. W roli ekstrahenta/przenośnika jonów użyto fosforanu tributylu (TBP). Zbadano zależność wydajności ekstrakcji od stężenia ekstrahenta. Wydajność ekstrakcji żelaza(III) wzrastała ze wzrostem stężenia TBP w nafcie. Najwyższy procent ekstrakcji jonów Fe(III) uzyskano przy 2,0 i 3,6 M TBP i wynosił on odpowiednio 99,5 i 99,8 %. Określono także wpływ zawartości plastyfikatora oraz przenośnika jonów w membranie na transport jonów żelaza(III) z kwaśnego roztworu chlorków Mn(II), Ni(II), Cu(II) i Co(II). W tych warunkach procesu transportu nie stwierdzono obecności jonów tych metali w fazie odbierającej. Ze wzrostem zawartości ONPOE od 0,6 do 2.0 cm3/g CTA wartość strumieni początkowych wzrastała. Przy stężeniu plastyfikatora wynoszącym 2,0 cm3/g CTA strumień początkowy wynosił 32,90 μmol/n2s. Z kolei wzrost stężenia przenośnika w membranie w zakresie od 0,5 do 1,5 M TBP (w przeliczeniu na objętość plastyfikatora) powodował wzrost wartości współczynnika przepuszczalności. Dalsze zwiększanie zawartości TBP nie wpływało na szybkość procesu. Wykorzystując mikroskopię sił atomowych (AFM) wykonano także analizę struktury powierzchni membrany zawierającej TBP, ONPOE i CTA oraz membrany z samego CTA.
EN
Competitive transport of Zn(II), Cd(II), and Cu(II) ions from aqueous chloride source phase (cMe = 0.01 M) through polymer inclusion membranes (PIMs) containing cellulose triacetate (support), o-nitrophenyl pentyl ether (plasticizer) and side-armed lariat ether-type derivative of diphosphaza-16-crown-6 (ion carrier) has been investigated. The influence of the group attached type to the PNP-lariat ether molecule on the selectivity and efficiency of Zn(II), Cd(II), and Cu(II) transport through polymer inclusion membranes is studied. The removal of metal ions by transport through PIM’s from acid aqueous phase into 0.1 M CH3COONH4, NH4OH or EDTA aqueous solution (receiving phase) is presented. The selectivity coefficient of Cd/Zn and Cd/Cu decreases with Cl- concentration increase in source phase for transport with bis-lariat ether, whereas for mono-lariat ether the selectivity coefficients are not changed.
PL
Zbadano selektywność procesu wydzielania jonów cynku(II), kadmu(II) i miedzi(II) z wodnych roztworów chlorkowych zawierających równomolową mieszaninę tych trzech metali (cMe=1,0ź10-2 M) w procesie transportu przez polimerowe membrany inkluzyjne (PIM) przy użyciu w roli przenośników jonów eterów PNP-difosfazakoronowych. Membrany typu PIM zbudowano z trójoctanu celulozy (nośnik), eteru o-nitrofenylopentylowego (pastyfikator) i eteru koronowego (przenośnik jonów); stężenie eteru w przeliczeniu na plastyfikator wynosiło 0,1 M. Współczynniki separacji Cd/Cu i Zn/Cu przez PIM przy użyciu mono-lariat eteru były porównywalne, podczas gdy przy użyciu bis-lariat eteru malały wraz ze wzrostem stężenia jonów Cl- w fazie zasilającej. Współczynniki separacji Cd/Cu wynosiły odpowiednio 8,7; 6,6 i 5,4 dla roztworu 0.1; 0.3 i 0.5 M HCl, natomiast współczynniki separacji Zn/Cu dla tych roztworów wynosiły odpowiednio 7.0; 6.3 i 1.2. Tak więc współczynniki separacji jonów kadmu do miedzi były wyższe niż jonów cynku do miedzi. Separacja jonów Cd/Zn nie zachodzi. W pracy przedstawiono ponadto wyniki transportu badanych jonów przy zastosowaniu różnych faz odbierających, tj., roztworu octanu amonu, wodorotlenku amonu i EDTA. Najwyższy procent wydzielenia jonów badanych metali uzyskano przy zastosowaniu CH3COONH4 (RF ≈ 80 %).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.