This research was aimed to find the structural behaviour of Calotropis procera fibres added concrete and the effect of Azadirachta indica leaf slurry blended to concrete and exposed to seawater. Conventional and fibre reinforced concrete samples fabricated keeping the curing time as 7, 14 and 28 dayswere subjected to compression, split tensile, rebound hammer and ultrasonic pulse velocity test. Increase in curing time increased the structural properties and Calotropis procerafibres added samples produced respectively 19.5%, 15%, 10.3 and 14.5% improvement in the compression, tensile, rebound hammer and ultrasonic pulse velocity values. These fibres reduced the brittleness of the specimen and avoided unprecedented failures. Accelerated corrosion and gravimetric mass loss test conducted to estimate the anti-corrosive property of Azadirachta indica leaf slurry showed decrease in corrosion rate. The corrosion rate of concrete samples without and with inhibitors was 0.0654 ± 0.008 and 0.056 ± 0.011 mm/year respectively evincing the anti-corrosive effects of Azadirachta indica leaves. Thus green materials are compatible with concrete and can be used in making sustainable concrete structures.
EN
The paper presents the results of electrochemical tests of the de-icing fluid for railway infrastructure. DC and AC electrochemical tests were performed to determine the corrosion rates of structural steel, cast iron and aluminium in the newly produced fluid. The results were compared with the corrosion rates of the same materials in the fluid without corrosion inhibitors. The obtained test results indicate a low corrosion risk of the de-icing fluid in the railway infrastructure in relation to the tested materials. The components of the fluid cause the surface passivation of materials that normally corrode in the active state. The efficiency of the inhibitors contained in the tested fluids reached a value of 90%. Corrosion rates obtained for the tested materials are many times lower than acceptable. The corrosion rates in the fluid without inhibitors, due to polyols used, are also very low. Research by electrochemical impedance spectroscopy (EIS) showed high values of the charge transfer resistance and increase in material resistance along with the time of action of the fluids.
PL
W pracy przedstawiono wyniki badań korozyjnych płynu do odladzania infrastruktury kolejowej. Wykonano badania elektrochemiczne stało- i zmiennoprądowe, na podstawie których określono szybkości korozji stali konstrukcyjnej, żeliwa oraz aluminium w nowo wytworzonym płynie. Wyniki porównano z szybkościami korozji tych samych materiałów w płynie stanowiącym odniesienie oraz w bazie płynu pozbawionej inhibitorów korozji. Uzyskane wyniki badań wskazują na niskie zagrożenie korozyjne płynu do odladzania infrastruktury kolejowej w stosunku do badanych materiałów. Składniki płynu prowadzą do pasywacji powierzchni materiałów, które w normalnych warunkach korodują w stanie aktywnym. Efektywność działania pakietu inhibitorów zawartego w badanych płynach wynosi ok. 50%. Szybkości korozji uzyskiwane dla badanych materiałów są wielokrotnie niższe niż akceptowalne. Szybkości korozji w płynie stanowiącym bazę, dzięki temu, że jest oparty na poliolach, również charakteryzują się bardzo niskimi wartościami. Badania metodą elektrochemicznej spektroskopii impedancyjnej wykazały wysokie wartości rezystancji przeniesienia ładunku oraz wzrost odporności materiału wraz z czasem oddziaływania preparatu.
4
Content available remote Anthocyanins – corrosion inhibitors straight from nature
EN
The growing environmental awareness is also reflected in the area of corrosion protection. Due to their full renewable nature and environmentally friendly profile, anthocyanins are undoubtedly a group of compounds that perfectly fit into the current trends related to the search for new, green corrosion inhibitors. In this article, the state of the art in the use of anthocyanin-rich plant extracts as corrosion inhibitors was briefly reviewed. Based on the results of works published in the past decade, the most important information about the protection of metal materials with the use of these compounds has been presented. The key results of analyzes enabling the monitoring of corrosion processes were described. The mechanism of inhibition of corrosive destruction, identical for anthocyanins, has been explained in an accessible way. Because of the specificity of their chemical structure, anthocyanins have the ability to strongly adsorb on the metal surface. Bonded to the substrate, they form a protective layer with a barrier effect. Anthocyanins play the role of mixed inhibitors, simultaneously inhibiting anode and cathode processes with an efficiency of up to 90%.
PL
Rosnąca świadomość ekologiczna znajduje odbicie również w sektorze ochrony przed korozją. Z uwagi na pełną odnawialność oraz przyjazny dla środowiska profil grupą związków doskonale wpisujących się w aktualne trendy związane z poszukiwaniem nowych, zielonych inhibitorów korozji są bez wątpienia antocyjany. W niniejszym artykule dokonano krótkiego przeglądu aktualnego stanu wiedzy w zakresie stosowania ekstraktów roślinnych bogatych w antocyjany w charakterze inhibitorów korozji. Korzystając z wyników prac opublikowanych w ostatniej dekadzie, przybliżono najważniejsze informacje dotyczące ochrony materiałów metalowych z wykorzystaniem tych związków. Przedstawiono kluczowe wyniki analiz umożliwiających monitorowanie procesów korozyjnych. W przystępny sposób wyjaśniono właściwy dla antocyjanów mechanizm inhibicji niszczenia korozyjnego. Ze względu na swoistość struktury chemicznej antocyjany wykazują zdolność do silnej adsorpcji na powierzchni metalu. Związane z podłożem, tworzą warstwę ochronną o działaniu barierowym. Antocyjany pełnią funkcję inhibitorów mieszanych, hamując równocześnie procesy anodowe i katodowe z wydajnością sięgającą nawet 90%.
PL
W celu ilościowej oceny przebiegu procesów korozyjnych konieczne jest zastosowanie monitorowania korozji w sposób bezpośredni. Celem monitorowania korozyjnego jest zastosowanie środków zaradczych pozwalających na przedłużenie czasu eksploatacji rurociągów, instalacji i urządzeń, a także kontrola i ochrona środowiska oraz bezpieczeństwo ludzi. Poprawnie skonstruowany i wdrożony system monitoringu korozji zmniejsza prawdopodobieństwo wystąpienia awarii, łagodzi skutki ewentualnej awarii, redukuje wpływ awarii na bezpieczeństwo społeczeństwa, pracowników przedsiębiorstwa, środowisko i ogranicza negatywny wizerunek operatora gazociągu. Pomiary szybkości korozji pozwalają przewidzieć powstanie perforacji i innych uszkodzeń korozyjnych. Monitorowanie pozwala także określić rozległość zagrożeń korozyjnych. Bardzo ważnym aspektem monitorowania korozyjnego są badania nieniszczące NDT umożliwiające kontrolę efektywności zastosowanych technologii ochrony przed korozją. Dla użytkownika instalacji ochrony katodowej (protektorowej), instalacji dozowania inhibitorów czy instalacji obróbki chemicznej niezwykle istotna jest rzeczywista szybkość korozji rurociągów. Znajomość tego parametru w różnych miejscach pozwala ocenić zasięg zastosowanej metody ochrony przed korozją oraz warunki jej eksploatacji, rozumiane jako optymalne dawki dozowania inhibitorów lub modyfikatorów, liczbę i rozmieszczenie anod oraz parametry prądowo/napięciowe w ochronie katodowej. Problem monitorowania korozji w celu zwiększenia bezpieczeństwa rurociągów wymaga nowego spojrzenia i nowych działań.
EN
If we take into account material issues and various methods of protection against corrosion of pipelines, presented below, it briefly introduces the complexity of corrosion processes. In order to quantitatively assess the course of corrosion processes, it is necessary to use corrosion monitoring directly. The purpose of corrosion monitoring is to use countermeasures to extend the life of pipelines, installations and equipment, as well as to control and protect the environment and human safety. Correctly constructed and implemented corrosion monitoring system reduces the likelihood of a failure, mitigates the effects of a possible failure, reduces the impact of failure on the safety of society, employees, the environment and reduces the impact of failure on the negative image of the gas pipeline operator. Corrosion rate measurements can predict perforation and other corrosion damage. Monitoring also allows you to determine the extent of corrosive hazards. A very important aspect of corrosion monitoring is NDT (non-destructive testing), checking the effectiveness of corrosion protection technologies used. For the user of cathodic (sacrificial) protection installations, inhibitor dosing installations or chemical treatment installations, the actual speed of pipeline corrosion is extremely important. Knowledge of this parameter in various places allows you to assess the range of the corrosion protection method used and the conditions of its operation understood as optimal dosages of inhibitors or modifiers, the number and distribution of anodes and current/voltage parameters in cathodic protection. The problem of corrosion monitoring in order to increase pipeline safety requires a new look and new action.
PL
Określono skuteczność ochrony antykorozyjnej dla stali S235JR przy zastosowaniu estru fenylometylonitrylobis(metylofosfonianu)dietylu oraz estru 1-fenyloetylonitrylobis(metylofosfonianu)dietylu w modelowych warunkach laboratoryjnych. Określono zależność skuteczności ochrony antykorozyjnej w czasie ekspozycji stali w środowisku wodnym o dużym zasoleniu. Wyniki badań wskazują na możliwość zastosowania obu związków jako inhibitorów korozji.
EN
Corrosion protection of S235JR steel was inhibited by addn. of PhCH₂N[CH₂CH₂P(O)(OEt)₂)]₂ and PhCH(Me)N[CH₂CH₂P(O)(OEt)₂]₂ under model lab. conditions. The effect of the storage time of aq. solns. of the newly synthesized compds. on the steel corrosion in an aq. medium with high salinity was detd. Both compds. were efficient as corrosion inhibitors.
EN
Corrosion inhibitors in the antifreeze include both inorganic and organic compounds. Organic additives applied in the antifreeze usually form thinner protective coatings. In spite of this fact, it is believed that they protect the exposed surfaces against corrosion more efficiently than fluids with inorganic additives. This work investigates whether the effects on the steel surface occurring due to the antifreeze meet key normative requirements. Microscopic imaging was used to identify the alterations in the surface invisible in the macro scale. The tests aimed to evaluate the potential of the antifreeze intended for combustion engines in the perspective of applying them in HVAC systems.
PL
Inhibitorami korozji w płynach niskokrzepnących mogą być związki nieorganiczne lub organiczne. Dodatki organiczne w płynach niskokrzepnących przeważnie tworzą cieńsze powłoki ochronne, mimo to uznaje się, że skuteczniej zabezpieczają narażone powierzchnie niż płyny z dodatkami nieorganicznymi. W niniejszej pracy zbadano efekty na powierzchni stali pojawiające się pod wpływem płynów niskokrzepnących spełniających kluczowe wymagania normatywne. Zastosowano mikroskopowe obrazowanie, które pozwoliło zidentyfikować zmiany powierzchni niewidoczne w skali makro. Badania miały na celu ocenę potencjału płynów niskokrzepnących do silników spalinowych w perspektywie ich wykorzystania w instalacjach grzewczo-chłodząco-wentylacyjnych.
PL
Instalacje grzewcze narażone są na szereg zagrożeń wynikających z jakości wody. Znajdujące się w niej jony wchodzą w reakcje między sobą (co jest przyczyną powstawania np. kamienia kotłowego) i z metalami tworzącymi elementy instalacji - rury i złączki.
PL
Przedstawiono wyniki badań elektrochemicznych przeprowadzonych dla substancji aktywnych w przemysłowo stosowanych preparatach antykorozyjnych. Badania przeprowadzono przy stałym stężeniu fosforu 30 mmol P/dm3 w celu porównania skuteczności ochrony antykorozyjnej związków o różnej ilości ugrupowań aminometylofosfonowych. W badaniach potwierdzono, że bardzo dobrą aktywność wykazują związki o parzystej ilości grup metylofosfonowych.
EN
The results of electrochemical tests carried out for active substances in industrially used anti-corrosive preparations are presented. The tests were carried out at a constant phosphorus concentration of 30 mmol P/dm3 in order to compare the effectiveness of anti-corrosive protection of compounds with different amounts of aminomethylphosphonic units. The tests confirmed that compounds with an even amount of methylphosphonic groups showed very good activity.
PL
W artykule przedstawiono szeroki zakres zagadnień dotyczących mikrozanieczyszczeń w środowisku naturalnym i antropogenicznym. Do omówionych zagadnień należą: źródła i występowanie mikrozanieczyszczeń w środowisku (w wodzie, glebie i powietrzu), ich los w środowisku, ekotoksyczność, sposoby ograniczania powstawania mikrozanieczyszczeń, szlaki przemian i produkty transformacji w środowisku, problematyka oczyszczania ścieków zawierających mikrozanieczyszczenia, prace badawcze dotyczące omawianej problematyki i przegląd wybranych rozwiązań w skali technicznej. Usuwanie mikrozanieczyszczeń stanowi aktualnie wiodący problem inżynierii środowiska. Wiedza o występowaniu tych zanieczyszczeń w środowisku jest już dość bogata, rozpoznano też częściowo jakie są ich losy w obiektach gospodarki wodnej i odpadami, także znaczny postęp nastąpił w zakresie znajomości efektywności technologii możliwych do zastosowania dla ich eliminacji ze środowiska. Rozwój technologii oczyszczania ścieków, a w mniejszym stopniu gospodarki odpadami, doprowadził już do usunięcia lub zmniejszenia zagrożenia spowodowanego znacznymi ilościami zanieczyszczeń, jednak aktualnie najbardziej palącym zagadnieniem jest występowanie mikrozanieczyszczeń, których działanie na środowisko przyrodnicze i człowieka nie można jeszcze oszacować. Ze względu na fakt, że występujące w środowisku mikrozanieczyszczenia antropogeniczne są bardzo zróżnicowane pod względem struktury chemicznej, a co się z tym wiąże – charakteryzują się innymi właściwościami fizyko-chemicznymi i w inny sposób działają na organizmy żywe obecne w środowisku, nie można wyróżnić jednego szlaku transformacji tych zanieczyszczeń. Mikrozanieczyszczenia antropogeniczne najczęściej nie są całkowicie rozkładane biologicznie, a ich transformacja związana jest ze zjawiskiem kometabolizmu oraz współdziałaniu określonych konsorcjów mikroorganizmów. Poszukiwaniu nowych, bardziej skutecznych, metod usuwania mikrozanieczyszczeń z środowiska powinna zawsze towarzyszyć ewaluacja toksyczności powstałych produktów. Produkty transformacji niektórych zanieczyszczeń były bardziej toksyczne w stosunku do organizmów wskaźnikowych niż substancje macierzyste. Głównym źródłem mikrozanieczyszczeń przedostających się do środowiska wodnego w krajach rozwiniętych (w przypadku terenów skanalizowanych) są komunalne oczyszczalnie ścieków. Z tego względu w artykule szczegółowo omówiono problematykę usuwania mikrozanieczyszczeń ze ścieków komunalnych w układach oczyszczania i doczyszczania ścieków. W artykule przedstawiono wyniki dotyczące usuwania wybranych mikrozanieczyszczeń (benzotriazol, mekoprop, diklofenak, sulfametoksazol i karbamazpina) w 11 rodzajach układów oczyszczania ścieków opartych zarówno na procesach biologicznych (oczyszczalnie hydrofitowe, stawy stabilizacyjne i układy z osadem czynnym), jak i fizyko-chemicznych (koagulacja, sorpcja na węglu aktywnym, zaawansowane procesy utleniania, fotoliza i ozonoliza) oraz różniących się zapotrzebowaniem powierzchni (co wynika z jednostkowej szybkości procesu) i konsumpcją energii (te dwa czynniki uznano za podstawę podziału na procesy intensywne i ekstensywne). Przedstawione w artykule zagadnienia stanowią podstawę do kreowania projektów badawczych, pozwalających przybliżyć moment w którym oczyszczalnie ścieków posiadać będą (czwarty) stopień, który zapewni likwidację zagrożeń wynikających z obecności w oczyszczonych ściekach substancji priorytetowych nawet w bardzo niskim stężeniu (co powodować może odległe w czasie skutki).
EN
The article presents a broad range of issues concerning micropollutants in the natural and anthropogenic environment. The issues discussed are: the source and occurrence of micropollutants in the environment (water, soil and air), their environmental fate, ecotoxicity, measures to reduce the produced amount of micropollutants, transformation pathways and transformation products in the environment, treatment of wastewater containg micropollutants, research projects dedicated to the discussed issues and a review of selected solutions on an industrial scale. Removal of micropollutants is currently a pressing problem of environmental engineering. Knowledge of the presence of these pollutants in the environment is already quite advanced, with partial understandingof their fate in waste and wastewater treatment processes. Also, significant progress has been made in the understanding of the applicability of various treatment methods and their effectiveness in the removal of micropollutants from waste streams. Development of wastewater treatment technology, and to a lesser extent, waste management, has already led to elimination or reduction of the risk posed by the significant amounts of pollution, but currently the most pressing issue is the presence of micropollutants whose effect on natural environment and humanrequires further studies. There is no single transformation pathway of micropollutants, due to the fact that they are diverse in terms of chemical structure, subsequently have various physico-chemical properties, and affect the organisms present in the environment in various manner. Anthropogenic micropollutants usually are not completely degraded biologically, and their transformation is associated with the phenomenon of co-metabolism and cooperation of certain consortia of microorganisms. The search for new, more effective, methods for removing micropollutants from the environment should always be accompanied by evaluation of the toxicity of the resulting products. Transformation products of certain micropollutants were more toxic to indicator organisms than the parent compounds. The main source of micropollutants entering the water environment in developed countries (in the case of sewered areas) are municipal wastewater treatment plants. For this reason, the article discussed in detail the issue of the removal of micropollutants from municipal wastewaterin the secondary and tertiary (post-treatment)treatment steps. The article presents the results for the abatement of selected micropollutants (benzotriazole, mecoprop, diclofenac, sulfamethoxazole and karbamazpina) in 11 types of wastewater treatment based on both biological processes (constructed wetlands, stabilization ponds and activated sludge systems) and physicochemical methods (coagulation, sorption on activated carbon, advanced oxidation, photolysis and ozonolysis), and the area requirements (due to the process rate) and the energy consumption (the two factors are the basis for the distinction between the intensive and extensive technologies). The issues presented in the article the basis for new research projects, allowing accelerating the moment in which the waste water treatment plants, will have a quaternary treatment step, which will significantly reduce of the risks of the presence of priority substances in the treated wastewatereven at very low concentrations (which may cause long-time effects).
11
Content available remote Wpływ pH roztworów na korozję wybranego gatunku stali
PL
Podczas eksploatacji odwiertów gazowych dochodzi do ubytku stali w otworze przy styku rur wydobywczych z rurą okładzinową, z czego wynika konieczność przeprowadzonych badań wpływu pH na intensywność korozji stali w miejscu styku rur okładzinowych i rur wydobywczych. Badania przeprowadzono w symulowanych warunkach temperatury i ciśnienia panujących w wytypowanym odwiercie. Wyniki badań potwierdziły, że płyn nadpakerowy powinien mieć odczyn pH ok. 12, co zmniejsza do minimum ubytki materiału konstrukcyjnego orurowania odwiertu na styku rura wydobywcza – rura okładzinowa.
EN
When using gas wells there is a loss of steel in the wellbore in the contact area between the production tubing and the casing string. Therefore, research on how pH influences the corrosion intensity along the contact point should be conducted. The research was carried out under simulated conditions of temperature and pressure in a selected wellbore. The results show that the pH of the packer fluid should be ca. 12, which helps to significantly reduce the loss of structural material at the interface between the pipes.
PL
Przedstawiono wyniki badań żywicy poliamfolitowej, jako potencjalnego inhibitora korozji stali węglowej w środowiskach symulujących ciecz porową betonu skażonego jonami chlorkowymi. W wyniku przeprowadzonych badań elektrochemicznych dobrano optymalną dawkę badanego związku, jako inhibitora korozji stali węglowej w badanych roztworach oraz wyznaczono chwilową szybkość korozji dla stali. Na podstawie widm uzyskanych z badań pod mikroskopem elektronowym przeanalizowano zmiany powstałe na powierzchni próbek.
XX
The paper presents the results of research on polyampholyte resin, in light of its potential application as a corrosion inhibitor for carbon steel, in environments simulating concrete pore liquid contaminated with chloride ions. As a result of the electrochemicalstudies conducted, the instantaneous corrosion rate for steel as well as the optimum dose of the test compound used as a carbon steel corrosion inhibitor in the test solutions were determined. On the basis of the spectra obtained in tests using an electron microscope, the changes on the surface of the samples were analysed.
PL
W artykule przedstawiono wyniki badań mających na celu dobór odpowiedniego zabezpieczenia antykorozyjnego wyposażenia odwiertów przeznaczonych do zatłaczania cieczy odpadowych i wody złożowej. Przed wykonaniem badań: zostały wytypowane roztwory korozyjne na podstawie przeglądu rodzajów cieczy odpadowych i wód złożowych przeznaczonych do zatłaczania, określono odmiany wytrzymałościowe stali wchodzących w skład wyposażenia odwiertów do zatłaczania cieczy odpadowych, wytypowano inhibitory korozji oraz ustalono warunki prowadzenia testów. Badania obejmowały: ocenę wpływu zatłaczanych cieczy odpadowych na wyposażenie wgłębne i rurociągi napowierzchniowe, testy korozyjne próbek stalowych z użyciem poszczególnych inhibitorów korozji (porównanie skuteczności wytypowanych inhibitorów między sobą) oraz dobór optymalnej dawki najbardziej skutecznych inhibitorów.
EN
In this article are presented results of research to determine adequate corrosion protection for oil wells designed for pumping wastes and reservoir waters. The corrosion solutions were selected after reviewing the types of wastes and reservoir waters intended for pumping. The author chose corrosion inhibitors and the variations of steel characterized by different mechanical strength which comprises well equipment. Conditions of corrosion tests were determined as well. Then the author did estimation of the influence of pumping wastes, on surface and underground well equipment and performed tests for the effectiveness of corrosion inhibitors (comparison of their performance) on metal coupons, to determine the adequate quantity of the inhibitors for the best corrosion protection.
PL
Korozja instalacji podczas procesu przeróbki ropy naftowej w rafineriach jest ogromnym problemem technicznym. Skutki procesów korozyjnych wiążą się zwykle z dodatkowymi, często znacznymi kosztami, dlatego też wykorzystywane są różne metody ochrony przed korozją. Jedną z rozpowszechnionych metod jest stosowanie inhibitorów korozji. W publikacji przedstawiono opis wykorzystywanych w INiG – PIB metod badań laboratoryjnych właściwości funkcjonalnych inhibitorów korozji dla przemysłu rafineryjnego oraz opis przemysłowych metod zapobiegania korozji w rafineriach.
EN
Corrosion in the plant during the processing of crude oil in refineries is a huge technical problem. Effects of the corrosion processes result in a considerable amount of additional costs, and therefore different methods of corrosion protection are used. One of the widespread methods of corrosion protection, is the use of corrosion inhibitors. This publication describes methods of laboratory testing of functional properties of corrosion inhibitors for the refinery industry and description of methods of preventing corrosion in refineries.
PL
W artykule przedstawiono wyniki badań mające na celu dobór odpowiedniego zabezpieczenia antykorozyjnego wyposażenia odwiertów przeznaczonych do zatłaczania cieczy odpadowych i wody złożowej. Przed wykonaniem badań zostały wytypowane roztwory korozyjne na podstawie przeglądu rodzajów cieczy odpadowych i wód złożowych przeznaczonych do zatłaczania, określono odmiany wytrzymałościowe stali wchodzących w skład wyposażenia odwiertów do zatłaczania cieczy odpadowych, wytypowano inhibitory korozji oraz ustalono warunki prowadzenia testów. Badania obejmowały ocenę wpływu zatłaczanych cieczy odpadowych na wyposażenie wgłębne i rurociągi napowierzchniowe, testy korozyjne próbek stalowych z użyciem poszczególnych inhibitorów korozji (porównanie skuteczności wytypowanych inhibitorów między sobą) oraz dobór optymalnej dawki dla najbardziej skutecznych inhibitorów.
EN
Results of research to determine adequate corrosion protection for oil wells designed to pumping wastes and reservoir waters are presented in this article. The corrosion solutions after the reviewing types of wastes and reservoir waters designed to pumping were selected. The corrosion inhibitors and the types of steel characterized by different mechanical strength which were belong to well equipment were chosen. Conditions of corrosion tests were determined too. Then estimation of influence of pumping wastes on surface and underground well equipment were done. The corrosion tests of effectiveness corrosion inhibitors (comparison of their performance) on metal coupons determine adequate quantity of the inhibitors for the best corrosion protection were performed.
16
Content available remote Corrosion inhibitors – application in oil industry
EN
The efficient flow of natural gas and oil to recipients is very often disrupted due to corrosion processes. They cause deterioration of material, leading to changes in their mechanical properties, such as durability, hardness or elasticity. In time, the progress of these phenomena causes damage to storage tanks or transmission systems which as a result, leads to leakage. Corrosion processes affect not only transmission and storage of fossils. The scale of the problem is much greater. Devices and systems corrode at the stage of exploration, production (corrosion of drilling equipment) and petroleum processing (corrosion of refinery plants). Currently, the opportunity to resolve the existing problems regarding corrosion, both for the domestic and global oil and gas industry is emerging. It is estimated that corrosion processes cost the American industry 280 billion dollars per year. Part of this sum is allocated to the oil and gas industry. Since this phenomenon cannot be stopped, more and more often the extent of damage to particular materials is being monitored. This solution seems to be economically justified. The article discusses mechanisms of the mentioned phenomenon, including also biocorrosion. Furthermore, some factors are presented which contribute to the occurrence of this unfavorable process in the oil industry. Additionally, some methods which decrease as well as prevent the effects of corrosion are discussed, with particular emphasis on corrosion inhibitors.
PL
Przepływ gazu ziemnego oraz ropy naftowej do odbiorców bardzo często ulega zakłóceniom, spowodowanym procesami korozji. Powodują one niszczenie materiału, polegające na zmianie jego właściwości mechanicznych, m.in. wytrzymałości, twardości czy sprężystości. Postępująca w czasie korozja przyczynia się do uszkodzenia zbiorników magazynujących czy instalacji przemysłowych, a w konsekwencji do wycieków danego surowca. Obecnie krajowy i światowy przemysł naftowy i gazowniczy stoi przed rozwiązaniem istniejących problemów związanych z tym zjawiskiem. Ponieważ nie da się zapobiec występowaniu korozji, coraz częściej podejmowane są działania kontrolujące stopień uszkodzenia danego materiału. Procesy korozji dotyczą nie tylko przesyłu i magazynowania wyżej wymienionych kopalin. Skala tego zjawiska jest znacznie większa. Korodowaniu ulegają m.in. urządzenia i instalacje na etapie poszukiwania, eksploatacji (korozja urządzeń wiertnicznych) oraz obróbki surowców (korozja instalacji rafineryjnych). Szacuje się, że procesy korozji kosztują amerykański przemysł 280 miliardów dolarów rocznie, z tego 1,4 miliarda dolarów pochłania sektor naftowy i gazowniczy. W artykule zostały omówione mechanizmy wyżej wymienionego zjawiska, z uwzględnieniem procesu biokorozji. Ponadto, przedstawiono czynniki, które przyczyniają się do występowania tego niekorzystnego procesu. Omówiono również sposoby łagodzenia i zapobiegania korozji, ze szczególnym uwzględnieniem zastosowania inhibitorów korozji.
PL
Celem pracy było określenie efektywności usunięcia ze ścieków wybranych mikrozanieczyszczeń antropogenicznych za pomocą sztucznych mokradeł. Układ laboratoryjny składał się z systemów obsadzonych Phalaris arundinacea oraz reaktorów nieobsadzonych roślinnością. W badaniach wykorzystano 2 farmaceutyki, tj. diklofenak i sulfametoksazol oraz 2 inhibitory korozji, a mianowicie: benzotriazol i benzotiazol. Wyniki badań pokazały, że substancją najbardziej podatną na rozkład był benzotiazol, a rośliny nie miały istotnego wpływu na efektywność procesów usuwania tych związków ze ścieków.
EN
The aim of this study was to determine the removal efficiency of selected anthropogenic micropollutants from wastewater by means of constructed wetlands. The lab-scale system consisted of several unplanted columns and columns planted with Phalaris arundinacea. In the study 2 pharmaceuticals were used, i. e. diclofenac and sulfamethoxazole and 2 corrosion inhibitors, namely benzotriazole and benzothiazole. The results showed that benzothiazole was the most susceptible to degradation and the plants did not have a significant impact on the effectiveness of abovementioned processes.
PL
Zbadano wpływ stężenia etyloksantogenianu potasu (KEtX) na korozję stali węglowej St3S w kwaśnym roztworze azotanów. Badania prowadzone były metodą elektrochemiczną. Stwierdzono, że wydajność inhibitowania korozji stali rośnie wraz ze wzrostem etyloksantogenianu potasu w roztworze. Na podstawie analizy krzywych polaryzacji stwierdzić można, że KEtX należy do grupy inhibitorów mieszanych. Adsorpcja etyloksantogenianu potasu na powierzchni stali opisana jest za pomocą izotermy Langmuira i zachodzi zgodnie z mechanizmem adsorpcji chemicznej. Wyznaczone zostały również parametry korozji stali St3S w badanym środowisku.
EN
The influence of the concentration of potassium ethylxanthate (KEtX) on the corrosion of St3S carbon steel in nitrate acid solutions was studied. The investigations involved electrochemical polarization methods. The inhibition efficiency increased with an increase in the concentration of potassium ethylxanthate. Tafel polarization study revealed that KEtX acted as a mixed-type inhibitor. The adsorption of potassium ethylxanthate has been found to occur on the surface of steel according to the Langmuir isotherm. The kinetic parameters for St3S corrosion and potassium ethylxanthate adsorption, respectively were determined and discussed.
PL
Efektywną ochronę przed korozją materiałów konstrukcyjnych przemysłowych wodnych układów chłodzących mogą zapewnić jedynie wielofunkcyjne preparaty inhibitorowe. Jednakże muszą one spełnić szereg wymagań użytkowych oraz wzrastających wymagań odnośnie ochrony środowiska. Przedstawiono właściwości żywic poliamfolitowych jako potencjalnych inhibitorów korozji stali węglowej w obojętnych środowiskach wodnych. Metodami elektrochemicznymi określono skuteczność ochrony inhibitorowej stali węglowej w wodzie modelującej wodę przemysłowych układów chłodzenia bez i z dodatkiem poliamfolitów.
EN
The effectiveness of inhibitory protection of structural materials found in industrial cooling water systems can only be provided by multifunctional compounds. However, they have to meet many technical, functional and environmental requirements. The chemical properties of polyampholyte resins, as potential corrosion inhibitors of carbon steel in neutral aqueous environments, are presented. Electrochemical methods were used to determine the effectiveness of the inhibitory protection of carbon steel in model water with and without polyampholytes.
PL
Przeprowadzono badania korozji stali zbrojeniowych w uszkodzonych płaszczach chłodni kominowej w środowisku wody chłodniczej, uzdatnianej związkami siarczanu i chlorku amonu. Badania prowadzono normową metodą grawimetryczną i elektrochemiczną z wykorzystaniem potencjostatu. Badania wykazały, że odporność korozyjna w roztworach zawierających sole amonu o stężeniu 0,15 mola/dm3, obliczona na podstawie szybkości korozji, była podobna i wyniosła 6 (w skali od 1 do 10). Stal S235JRG2 wykazała nieco wyższą odporność w tych środowiskach.
EN
Corrosion testing was performed on structural steel of a cooling tower in the environment of cooling water containing ammonium sulfates and ammonium chloride. The test were performed using gravimetric and electrochemical methods with the application of a potentiostat. The analyses clearly showed that the corrosion rate is higher in solutions that contain ammonium sulfate and that the S235JRG2 steel exhibits higher corrosion resistance in this environment.