Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 17

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  in situ measurements
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Spatiotemporal variability of wave climate in the Gulf of Riga
EN
Basic properties of wind wave climate in the Gulf of Riga, the Baltic Sea, are evaluated based on modelled wave fields, instrumentally measured and historical visually observed wave properties. Third-generation spectral wave model SWAN is applied to the entire Baltic Sea for 1990–2021 with a spatial resolution of 3 nautical miles (nmi, about 5.5 km) forced by the wind field of ERA5, to the Gulf of Riga and its entrance area with a resolution of 1 nmi (about 1.85 km), and to nearshore areas of this gulf with a resolution of 0.32 nmi (about 600 m). The calculations are performed for an idealised ice-free climate. Wave properties are represented by 36 directional and 32 frequency bins. The simulations are complemented by five sessions of instrumental measurements in the 2000s and two sets of historical visual wave observations from the island of Ruhnu and the Sõrve Peninsula for 1954–2011. Predominantly representing fetch-limited windseas, the wave climate in the gulf is milder and more intermittent than in the open Baltic Sea. The average significant wave height is mostly in the range of 0.6–0.8 m and peaks at 0.82 m inside the gulf. Typical wave periods are shorter than in the Baltic proper. The spatial pattern of wave heights, with higher wave intensity in the northern and eastern parts of the basin, follows anisotropy in wind conditions. Interannual variations are highly synchronised in different parts of the gulf. Their magnitude is less than 10% of the long-term average wave height. No long-term trend has been found in significant wave height and no distinct decadal variation exists inside the gulf.
PL
W pracy przedstawione zostały wyniki pomiarów promieniotwórczości naturalnej i antropogenicznej skał w rejonie Gór Opawskich i ich zachodniego przedpola. Pomiary w warunkach in situ przeprowadzono na 13 stanowiskach. Dodatkowo z każdego stanowiska pobrana została próbka skalna do badań w warunkach laboratoryjnych. Do badań został użyty przenośny system spektrometryczny promieniowania γ GX3020. Aktywność promieniotwórcza izotopu toru 232Th zmieniała się w granicach od 5 Bq kg−1 do 71 Bq kg−1 w pomiarach laboratoryjnych i od 2 Bq kg−1 do 71 Bq kg−1 w pomiarach in situ. Zmierzona aktywność promieniotwórcza uranu 238U w warunkach laboratoryjnych wynosiła od 4 Bq kg−1 do 52 Bq kg−1, a w warunkach terenowych od 7 Bq kg−1 do 48 Bq kg−1. W warunkach laboratoryjnych aktywność promieniotwórcza potasu 40K zmieniała się w granicach od 12 Bq kg−1 do 1560 Bq kg−1, natomiast w warunkach in situ w granicach od 60 Bq kg−1 do 1700 Bq kg−1. Uzyskane wartości aktywności promieniotwórczej zostały następnie porównane ze średnią aktywnością promieniotwórczą tego typu skał w Sudetach i na świecie. W pracy przedstawione zostały wyniki pomiarów promieniotwórczości naturalnej i antropogenicznej skał w rejonie Gór Opawskich i ich zachodniego przedpola. Pomiary w warunkach in situ przeprowadzono na 13 stanowiskach. Dodatkowo z każdego stanowiska pobrana została próbka skalna do badań w warunkach laboratoryjnych. Do badań został użyty przenośny system spektrometryczny promieniowania γ GX3020. Aktywność promieniotwórcza izotopu toru 232Th zmieniała się w granicach od 5 Bq kg−1 do 71 Bq kg−1 w pomiarach laboratoryjnych i od 2 Bq kg−1 do 71 Bq kg−1 w pomiarach in situ. Zmierzona aktywność promieniotwórcza uranu 238U w warunkach laboratoryjnych wynosiła od 4 Bq kg−1 do 52 Bq kg−1, a w warunkach terenowych od 7 Bq kg−1 do 48 Bq kg−1. W warunkach laboratoryjnych aktywność promieniotwórcza potasu 40K zmieniała się w granicach od 12 Bq kg−1 do 1560 Bq kg−1, natomiast w warunkach in situ w granicach od 60 Bq kg−1 do 1700 Bq kg−1. Uzyskane wartości aktywności promieniotwórczej zostały następnie porównane ze średnią aktywnością promieniotwórczą tego typu skał w Sudetach i na świecie. Obecność antropogenicznego izotopu cezu 137Cs została stwierdzona na 7 stanowiskach. Depozycja tego izotopu zmieniała się w granicach od 38 Bq m−2 do 6344 Bq m−2. W pracy dokonano również pomiarów wartości mocy dawki pochłoniętej promieniowania γ. Uzyskane wyniki zmieniały się w zakresie od 10 nGy h−1 do 223 nGy h−1, przy czym średnia wartość mocy dawki pochłoniętej promieniowania γ w Polsce wynosi 45,6 nGy h−1. Jednym z celów niniejszej pracy było także określenie korelacji pomiędzy koncentracjami podstawowych radionuklidów. Wyniki badań pokazują, że koncentracje 232Th [ppm] i 238U [ppm], K [%] i 232Th [ppm] oraz K [%] i 238U [ppm] wykazują na ogół silną, dodatnią korelację. Badania promieniotwórczości naturalnej skał Gór Opawskich i ich zachodniego przedpola przeprowadzone w warunkach laboratoryjnych i in situ wykazały się dużą zgodnością. Największa różnica pomiędzy aktywnościami wyznaczonymi oboma sposobami wyniosła 140 Bq kg−1.
EN
Measurements of natural and anthropogenic radioactivity were carried out in characteristic lithologies in the Opava Mountains and their western foreland (SW Poland). In situ measurements were conducted at 13 locations and rock samples from each site were collected for laboratory measurements. The activity concentrations of the naturally occurring radionuclides and fallout of 137Cs were measured using a portable HPGe gamma-ray spectrometry. The ranges of the activity concentrations of 232Th were 5–71 Bq kg−1 in the laboratory and 2–71 Bq kg−1 for the in situ measurements. For 238U, the activity concentrations ranged from 4–52 Bq kg−1 in the laboratory and from 7–48 Bq kg−1 under in situ field conditions, and for 40K, the ranges were 12–1560 Bq kg−1 in the laboratory and 60–1700 Bq kg−1 for in situ measurements. Measured activity concentrations were compared with average activity concentrations of the radionuclides in similar types of rocks from different global localities and with data from the Sudetes available in the literature. Anthropogenic 137Cs was observed at seven locations with deposition from 38 to 6344 Bq m−2. The external gamma-dose rate varied from 10 to 223 nGy h−1, whereas the average gamma-dose rate in Poland is 45,6 nGy h−1. One of the goals of this work was also to determine the correlation between naturally occurring radionuclides. In the investigated rocks, concentrations of 232Th [ppm] and 238U [ppm], K [%] and 232Th [ppm], and K [%] and 238U [ppm] had a strong positive correlation. No significant differences were found between the in situ and laboratory measurements. The maximum absolute difference between the in situ and laboratory measurements was 140 Bq kg−1 for 40K.
EN
The sound power level as a parameter characterizing a sound source, as opposed to the sound pressure level, should theoretically not depend on the place of measurement and distance from the source. Therefore, it is often used as a basis for comparing machines and equipment in terms of noise emissions. Manufacturers usually specify this parameter in the technical documentation or on the equipment. The sound power level is also a necessary parameter for modelling the natural and working environment in terms of acoustics. The standards for methods of determining the sound power level define three classes of accuracy depending on the method and environment of measurement. The paper outlines the problems associated with determining the sound power level of non-standard machines in situ. The case study concerns a machine, a modular SRP (shelf ready packaging) production system that can be part of an extensive production line. Specific for this type of machine is the coexistence of many local sources generating sound of different nature, cyclic mode of operation and the possibility to set different capacity.
4
Content available remote Façade scaffolding behaviour under wind action
EN
The main objective of the study was to estimate the mean horizontal wind action on a façade scaffolding on the basis of full-scale data. Measurements of climatic parameters were carried out for a number of façade scaffoldings (120 structures) located in Poland over a 30-month period. The measurement points were located on 2–3 deck levels of each structure and at 2–4 points placed in each level. The measurements were carried out 3–4 times during each day for 5 consecutive days. At each point, two components of wind speed were measured: first with the vane probe directed perpendicular to the façade and then parallel to the façade. Each measurement lasted 60 s, and the data were recorded every 1 s. On the basis of wind speeds, a procedure was suggested that enabled estimation of the static wind action on façade scaffoldings. The responses of structures to this action were computed via FEM simulations. The results were compared with those based on the approaches recommended by the wind and scaffolding codes. Initial analyses, illustrated by three scaffoldings without a protective cover, indicated large discrepancies between the approaches and the possibility of wind action, which is not considered in the codes.
EN
This paper reports on the abundance of primordial radionuclides (40K,232K and 238U) in characteristic lithologies from the Sowie Mountains (SW Poland). In situ gamma-ray measurements were conducted at 12 localities hosting exposed augen gneiss, flaser gneiss, granulite, homophanized gneiss, hornblendite, layered gneiss, layered migmatite, migmatic gneiss, mylonitic gneiss and mylonitic granulite. The activity concentration of 40K varied from 180 Bq kg-1 (mylonitic granulite) to 845 Bq kg-1 (layered gneiss). The activity concentrations associated with 228Ac (232Th) varied from 10 Bq kg-1 (mylonitic granulite) to 53 Bq kg-1 (homophanized gneiss), while activity associated with 226Ra (238 U) varied from 9 Bq kg-1 (mylonitic granulite) to 43 Bq kg-1 (layered gneiss). An augen gneiss adjacent to the Intra-Sudetic Fault showed the highest combined Th + U activity (89 Bq kg-1). The average Th/U ratio (3.6) calculated for gneiss outcrops of the Sowie Mountains falls within the range reported for biotite gneiss (3.5-4). Subsurface outcrops from the Walim-Rzeczka underground complex did not give noticeably higher 238U activities. The results obtained forthe Sowie lithologies are compared with those obtained by similar methods for similar rocks as reported in literature sources.
PL
Na długości wyrobiska korytarzowego często dochodzi do zmian warunków górniczo-geologicznych, a jedną z przyczyn zaistniałych zmian jest obecność nierozpoznanej wcześniej strefy uskokowej. Doświadczenia pokazują, że jest to jeden z głównych czynników wpływających na problemy z utrzymaniem stateczności wyrobiska korytarzowego. Największym problemem przy ocenie wpływu strefy uskokowej na obciążenia obudowy jest ocena zasięgu strefy osłabienia (spękania) górotworu, jak i ilościowej oceny spadku właściwości mechanicznych skał. Według światowych badań strefa może wynosić od 1-2 metrów lub sięgać aż do czterokrotnej wartości wysokości zrzutu danego uskoku. Ponieważ w rejonie Górnośląskiego Zagłębia Węglowego zjawisko występowania małych uskoków na wybiegu wyrobiska jest bardzo powszechne, w artykule przedstawiono wpływ strefy uskokowej na stateczność chodnika podścianowego D-2 w kopalni KWK „Borynia- Zofiówka-Jastrzębie”. Wpływ ten przedstawiono na podstawie pomiarów dołowych konwergencji wyrobiska oraz za pomocą metod numerycznych. Wykonane badania pokazały, że dla celów inżynierskich można to zadanie wykonać za pomocą modelu płaskiego. Odpowiednie odwzorowanie uskoku modelem sprężysto-plastycznym z 20-procentowym osłabieniem pozwoliło otrzymać wyniki obliczeń numerycznych charakteryzujące się dużą zgodnością z wynikami pomiarów konwergencji wyrobiska w warunkach in situ. Stwierdzono, że zasięg zniszczenia górotworu w pionie sięga w stropie do wysokości dwóch zrzutów uskoku, w spągu do 3 zrzutów uskoku, a w ociosach do dwukrotnej wartości zrzutu uskoku. Na jego zasięg wpływa przede wszystkim wytrzymałość warstw skalnych znajdujących się poza strefą uskokową, a nachylenie sprawia, że strefa uplastycznienia jest niesymetryczna. Konwergencja chodnika o prawidłowo dobranej obudowie, znajdującego się w strefie uskoku nawet o małym 5-metrowym zrzucie jest 3,5–4,5-krotnie większa niż na odcinkach niezaburzonych tektonicznie. Najistotniejsze jest przy tym wypiętrzanie spągu, które może lokalnie dochodzić do 1,8 m, co zawsze będzie sprawiać problemy z utrzymaniem stateczności wyrobiska korytarzowego na odcinku z osłabionymi i przesuniętymi względem siebie warstwami skalnymi.
EN
There are many cases where geological and mining conditions change along the mining roadway. The primary unknown throw fault zones are often the reason of the problems for mining engineers. Based on experience, this is one of the main factor influences on mining workings stability. The key problem is to determine the range of the weaken zone in the vicinity of a fault zone which affects the load on a designed support. The worldwide research has shown that the range can be 1-2 m or reaches even 4-fold of the fault throw. As the small throw fault zones are very common in the conditions of Upper Silesia Coal Basin, this paper presents the research of fault zone influence on the roadway stability. The results of the numerical calculations are shown and in situ convergence measurements carried out in the maingate D-2 in the “Borynia-Zofiówka- Jastrzębie” coal mine as well. The proper modelling – elastic-plastic model with 20% weakening of rock mass properties – provided good accuracy between the calculations and measurements. Based on the results of research, it may be concluded that the rock mass displacements around roadway section within a fault zone reach: in the roof - two times the throw of the fault, in the floor - three times the throw, and horizontally nearly up to two times the width of the modelled fault zone. The convergence of the working, even whether the support has been designed properly, in the case of a 5-meter throw of the fault will be 3.5-4.5 higher than for the section of the roadway unaffected by the fault zone. A floor heaving which can reached even 1.8 m, is the most important for mining practice. It will always cause problems with the roadway maintenance, as the rock mass is strongly disturbed in such a zone and the rock beds are dislocated.
PL
Przedmiotem artykułu jest analiza porównawcza wyników obliczeń konsolidacji podłoża wzmocnionego wymianą dynamiczną, pod nasypem drogowym, otrzymanych na podstawie wybranych podejść analitycznych i numerycznych z wynikami pomiarów in situ prowadzonych w trakcie budowy. W podejściu analitycznym zastosowano jednowymiarową teorię Terzaghiego oraz trójwymiarową teorię Barrona. W obliczeniach numerycznych zamodelowano etapową budowę nasypu w układzie dwuwymiarowym. Przeprowadzona analiza wykazała, że pomierzone osiadania podłoża pod budowanym nasypem były zbliżone do ustalonych w wyniku obliczeń.
EN
The paper presents the comparative consolidation analysis of road embankment subsoil reinforced with the use of the dynamic replacement method. The results obtained from selected analytical and numerical methods applied in the dynamic replacement column dimensioning were compared with in situ measurements. The embankment founded on strengthened soil was monitored during its completion. The measurements were taken with accuracy and the results can be considered trustworthy. The analytical approach uses the one-dimensional theory of Terzaghi and three-dimensional theory of Barron. The numerical calculations using FEM reflected the particular stages of the embankment construction in a two-dimensional system. The measured settlements and the results of the calculations (dimensioning) by two different approaches were coherent. The paper can be considered as a case study report.
PL
W artykule została opisana metodyka pomiarów oddziaływania wiatru na rusztowania budowlane. Założono, że rusztowania ustawione są przy budynkach, a badania prowadzone są w skali naturalnej. Do badań wykorzystano rozbudowany system składający się z anemometrów ultradźwiękowych: pięciu dwukierunkowych oraz jednego trójkierunkowego.
EN
The article describes the methodology of in-situ measurements of wind action on scaffoldings. An elaborated system consisting of five 2D and one 3D ultrasonic anemometer was used to conduct measurements.
EN
In the north-eastern part of Poland, the underground gas stores are being constructed by diluting salt deposits. Brine, a by-product of the technology applied, is discharged into the coastal waters of the south Baltic Sea by a system of diffusers. To assess the intensity of brine mixing in the near-field of the discharge installation, a monitoring program was carried out. The results demonstrated that under the mildly dynamic conditions of Puck Bay, the discharge of brine (saturation 250 kg m-3, discharge 300 m3 h-1) leads to salinity excess below 0.5 PSU. For parameters of a real brine discharge, the dilution coefficient estimated by formulas derived from analytical solutions, predictive models and laboratory experiments for stagnant water conditions, varied in the range of 123÷360. The dilution coefficient value estimated on the basis of measurements was 1.27÷3.72 times higher than its value obtained by the use of predictive models, while estimated by formulas obtained from laboratory experiments was in the range of 1.41÷2.26 of the dilution coefficient based on measurements.
PL
W pracy podano sposób badania i oceny efektywności energetycznej budynków na przykładzie wybranych pomieszczeń obiektu biurowego użytkowanego w polskich warunkach klimatycznych. Pomieszczenia dostosowano do standardu zeroenergetycznego. Źródłem zasilania są zintegrowane z nimi urządzenia energetyki odnawialnej. Przeprowadzono pomiary dynamiki cieplnej ściany zewnętrznej oraz energii elektrycznej produkowanej przez panele fotowoltaiczne zainstalowane na zewnętrznej powierzchni ściany. Zaproponowano metodę bilansowania strumieni energii na granicy pomieszczenia, czyli przegród ograniczających kubaturę o kontrolowanych parametrach środowiska wewnętrznego. Dokonano analizy wyników biorąc pod uwagę periodyczny charakter zmian poszczególnych wielkości, długości okresów nieciągłości oraz uzyskane wartości ekstremalne. Na podstawie wyników z analizowanego okresu stwierdzono, że uzyskanie standardu obiektu autonomicznego jest niezwykle trudne, natomiast możliwe jest spełnienie kryteriów obiektu niemal zero-energetycznego.
EN
The method of building energy performance assessment was presented and discussed. As an example of the building part under Polish climatic conditions two experimental rooms were developed and constructed. The measurement results obtained for two facades, ,oriented east and west, were analysed and discussed. The following physical parameters were measured in-situ: electricity produced by PV panels and thermal dynamic of external partition. Based on the monitoring results authors proposed the method to determine the energy efficiency of such system to obtained nearly zero energy standard.
EN
The paper reviews nowadays problems and issues of wind engineering and aerodynamics of building structures. The article mainly focuses on aerodynamics of building structures, shortly characterizing theoretical bases, which one must take into account when assuming wind loads. The three different approaches of collecting information in the field of wind loads are described: in-situ measurements, wind tunnel tests and numerical simulations. Also, a review of the most important contemporary issues of wind engineering is presented.
PL
W artykule opisane zostały aktualne zagadnienia, jakimi zajmuje się inżynieria wiatrowa i aerodynamika budowli. Skoncentrowano się głównie na aspektach związanych z aerodynamiką budowli. W pracy krótko przedstawiono podstawy teoretyczne, które należy uwzględnić przy przyjmowaniu obciążenia wiatrem. Następnie opisano trzy różne instrumenty badawcze służące do opisu obciążenia wiatrem: badania w skali rzeczywistej, badania w tunelach aerodynamicznych oraz symulacje komputerowe. Na zakończenie dokonano przeglądu aktualnych problemów podejmowanych przez inżynierię wiatrową.
PL
W artykule przedstawiono wyniki badań pomiaru wilgotności i temperatury w przegrodzie ocieplonej od wewnątrz. Pomiary wykonano w oparciu o zaproponowaną przez Autorów metodykę doboru rodzaju ocieplenia [6,7] jak również o badania wstępne polegające na opracowaniu modelu przegrody, dla którego obliczono ryzyko kondensacji powierzchniowej i międzywarstwowej. Wytypowano również miejsca potencjalnych mostków termicznych z propozycją ich rozwiązań. W części drugiej pracy na podstawie prowadzonego pomiaru temperatury i wilgotności opracowano profil rozkładu badanych parametrów dla przegrody i odniesiono go do wielkości uzyskanych w oparciu o obliczenia cieplno-wilgotnościowe z pierwszej części pracy. W ramach badań tj. pomiaru temperatury wykonano pomiar termowizyjny w celu określenia rozkładu pola temperatur na przegrodzie. Wyniki porównano w wartościami temperatur uzyskanymi dla modelu przegrody opracowanej w programie Therm 7.3.
EN
This article presents the results of research on humidity and temperature measurement in a partition insulated from inside. The measurements were taken on the basis of a method (proposed by the authors) of selecting the type of insulation as well as on the basis of initial research whose aim was to establish a partition model for which the risk of surface and inner layer condensation was calculated. Spots where possible “thermal bridges” may occur have also been given together with solutions to this problem. The second part presents the profile of parameters distribution in a partition and this has been referred to the results reached on the basis of heat-humidity calculations form the first part. Temperature measurement included taking thermal image with the view of establishing temperature distribution in a partition. The results have been compared to temperatures established for partition model set in Therm 7.3 programme.
13
PL
Referat zawiera opis badań związanych z mieszankami mineralno–cementowo-emulsyjnymi (MCE). Zostały opisane dotychczasowe doświadczenia związane z oceną odcinków dróg wykonanych z wykorzystaniem tej technologii, ich stan techniczny oraz występujące uszkodzenia po kilku latach eksploatacji nawierzchni. Przedstawione zostaną wyniki badań mieszanek mineralno-cementowo-emulsyjnych prowadzone w celu optymalizacji składu tych mieszanek. W końcowej części publikacji zostanie przedstawiona nowa instrukcja do projektowania mieszanek MCE, jaka powstała w wyniku prowadzonych prac.
EN
The paper describes the researches related to mineral-cement-emulsion mixes (MCE). Previous experiences related to the assessment of road sections made using this technology are described, their technical condition and damage occurring after a few years of exploitation are discussed. In the paper will be presented the results of researches of mineral-cement-emulsion carried out in order to optimize the composition of these mixtures. In the final part of the publication will be presented the new standard method to design mineral-cement-emulsion mixes (MCE), which is the result of work carried out.
14
PL
W artykule zostaną zaprezentowane praktyczne przykłady braku kompatybilności elektromagnetycznej w urządzeniach o znacznych wymiarach, z którymi spotkał się zespół akredytowanego Laboratorium Badań EMC, działającego w ramach Zakładu Kompatybilności Elektromagnetycznej Instytutu Łączności - PIB we Wrocławiu. Pokazane przykłady praktyczne zebrane na bazie wieloletniej współpracy między zespołem laboratorium, a producentami urządzeń górniczych zilustrują problemy związane z wyłączeniami się maszyn, zatrzymaniami taśmy przenośnika, awariami różnych układów. Badania, z których pochodzą przedstawione w artykule przykłady zostały wykonane w warunkach in situ.
EN
The paper some practical examples of the lack of electromagnetic compatibility in large size equipment, some typical problems encountered by the team of accredited EMC Testing Laboratory of National Institute of Telecommunications, Electromagnetic Compatibility Department, Wroclaw. The examples given here, gathered during several years of experience and collaboration between laboratory team and manufacturers of mining equipment will illustrate some problems related with machines switch-offs, conveyor belt stopping, numerous breakdowns. Examples presented in the paper were gathered during in situ tests.
EN
In situ monitoring of the thickness of thin diamond films during technological processes is important because it allows better control of deposition time and deeper understanding of deposition kinetics. One of the widely used techniques is laser reflectance interferometry (LRI) which enables non-contact measurement during CVD deposition. The authors have built a novel LRI system with a 405 nm laser diode which achieves better resolution compared to the systems based on He-Ne lasers, as reported so far. The system was used for in situ monitoring of thin, microcrystalline diamond films deposited on silicon substrate in PA-CVD processes. The thickness of each film was measured by stylus profilometry and spectral reflectance analysis as a reference. The system setup and interferometric signal processing are also presented for evaluating the system parameters, i.e. measurement uncertainty, resolution and the range of measurable film thickness.
PL
Głównym celem pracy jest ocena możliwości wyznaczenia współczynników wymywania na podstawie pomiarów rzeczywistych stężenia pyłu zawieszonego o frakcji poniżej 2,5 /žm (PM) oraz natężenia i rodzaju opadu, prowadzonych w sposób ciągły, a także ocena zmienności stężenia pyłu zawieszonego w zależności od warunków opadowych. W analizie wykorzystano dane zgromadzone w Obserwatorium Zakładu Klimatologii i Ochrony Atmosfery Uniwersytetu Wrocławskiego. Pyłomierz TEOM 1400a zapewniał ciągły monitoring pyłu zawieszonego PM 5. Pomiar opadu był przeprowadzony przy użyciu laserowego miernika opadu Parsivel. W pracy przedstawiono analizę danych zgromadzonych w okresie od początku maja 2010 do końca kwietnia 2011. Wyliczone współczynniki wymywania na podstawie całego zbioru danych wahały się w bardzo szerokich granicach, od -0,02311 do 0,05380 s-1. Ponieważ intensywność usuwania aerozolu atmosferycznego najczęściej jest określana medianą ze zbioru wszystkich wyliczonych wielkości współczynnika wymywania, wielkość ta w analizowanym okresie wyniosła 3,28^10'5 s-1. Wynik ten jest zbliżony do wielkości podawanych w literaturze. Charakterystyka współczynników wymywania została również przedstawiona w zależności od rodzaju opadu i jego natężenie (tab.4). Średnia i mediana współczynnika wymywania w poszczególnych typach wahała się w zakresie 10-4 – 10-5 s-1 największe wartości przyjmując w przypadku mżawki o słabym natężeniu (Me=1,62^10-4), deszczu z mżawką (Me = 1,07^10-4) i deszczu marznącego (Me=1,4140-4). Ponadto uwagę zwracają przypadki nietypowe, nieodpowiadające schematowi: wystąpienie opadu wymywanie PM z atmosfery. Ich występowanie wskazuje, że w dalszych analizach należy uwzględnić dodatkowe, niezwiązane z opadem czynniki, mogące wpływać na zmienność stężenia pyłu zawieszonego.
EN
The main objective of presented work was to determine the variability of particulate matter less than 2,5/žm (PM2.5), in relation to actual weather conditions. The analysis was based on the data collected by Meteorological Observatory of Department of Climatology and Atmosphere Protection (Wrocław University). Continuous monitoring of PM2 5 was carried out by automatic dust concentration monitor TEOM 1400a. For the measurement of precipitation optical disdrometer PARSIVEL was used. The paper presents an analysis of data collected in the period from the start of May 2010 to the end of April 2011. The scavenging coefficients calculated for the entire dataset ranged in the wide limits, between -0,02311 and 0,05380 s-1. The intensity of the atmospheric aerosol removal is most often described as the median of dataset of all calculated coefficients, so for analyzed period its value was determined on 3,28 10-5 s-1. This result is close to the values reported in the literature. Characteristics of scavenging coefficients for different intensities and types of precipitation were also calculated. Average value and median of scavenging coefficient for each type of precipitation ranged from 10-4 to 10-5 s-1. Maximum values were calculated for low intensity drizzle (Me=1,62-10-4), rain with drizzle (Me=1,07-10-4) and freezing rain (Me = 1,41-10-4). The cases that do not correspond to the scheme: occurrence of precipitation ^ intensive scavenging are especially noteworthy. Their presence points, that further analysis should take into account additional factors, not related to precipitation, which may affect variations of particulate matter concentration.
PL
Pomiary izolacyjności cieplnej przegród budowlanych in-situ są istotne dla prawidłowej oceny jakości energetycznej budynków istniejących. W poniższym artykule przedstawiono problemy pojawiające się przy pomiarach in-situ współczynnika przewodzenia ciepła X oraz charakterystyk izolacyjności cieplnej R i U przegród budowlanych.
EN
In-situ measurements of thermal quality of building partitions are necessary for correct energy performance evaluation of existing buildings. Article describes problems which can occur during in-situ measurements of thermal conductivity (X) and thermal characteristics like thermal resistance (R) and heat transfer coefficient (U).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.