1
Content available remote Pupillometry via smartphone for low-resource settings
EN
The photopupillary reflex regulates the pupil reaction to changing light conditions. Being controlled by the autonomic nervous system, it is a proxy for brain trauma and for the conditions of patients in critical care. A prompt evaluation of brain traumas can save lives. With a simple penlight, skilled clinicians can do that, whereas less specialized ones have to resort to a digital pupilometer. However, many low-income countries lack both specialized clinicians and digital pupilometers. This paper presents the early results of our study aiming at designing, prototyping and validating an app for testing the photopupillary reflex via Android, following the European Medical Device Regulation and relevant standards. After a manual validation, the prototype underwent a technical validation against a commercial Infrared pupilometer. As a result, the proposed app performed as well as the manual measurements and better than the commercial solution, with lower errors, higher and significant correlations, and significantly better Bland-Altman plots for all the pupillometry-related measures. The design of this medical device was performed based on our expertise in low-resource settings. This kind of environments imposes more stringent design criteria due to contextual challenges, including the lack of specialized clinicians, funds, spare parts and consumables, poor maintenance, and harsh environmental conditions, which may hinder the safe operationalization of medical devices. This paper provides an overview of how these unique contextual characteristics are cascaded into the design of an app in order to contribute to the Sustainable Development Goal 3 of the World Health Organization: Good health and well-being.
PL
Niniejszy artykuł jest wykładem wygłoszonym podczas uroczystości nadania tytułu doktora honoris causa Politechniki Śląskiej prof. zw. dr hab. n. med. Aleksandrowi Sieroniowi. Autor omawia istotną rolę światła w diagnostyce i terapii onkologicznej. Krótko opisuje także wykorzystanie światła w walce z drobnoustrojami.
EN
This article is a lecture given during the ceremony of awarding the title of doctor honoris causa of the Silesian University of Technology | to professor Aleksander Sieroń. The author discusses the important role of light in oncology diagnosis and therapy. It also briefly describes the use of light in the fight against microbes.
PL
W artykule przedstawiono zarys historyczny powstawania i kształtowania się zawodu inżyniera medycznego. Zaznaczone zostały najważniejsze wydarzenia mające istotny wpływ na określenie, czym jest ten zawód i jego roli w ochronie zdrowia.
EN
The article outlines the historical development of the medical engineering profession. The most important events determined this profession and its role in health care are pointed.
PL
W artykule przedstawiono, jak po raz pierwszy w ubiegłym roku, dnia 21 października, obchodzony był Międzynarodowy Dzień Inżynierii Klinicznej.
EN
The article describes the celebration of the Global Clinical Engineering Day on October the 21st 2016.
PL
Inżynieria medyczna, ze względu na swoją specyfikę, reprezentowana jest w International Federation of Biomedical Engineering przez specjalną sekcję CED/IFMBE (Clinical Engineering Division). W artykule przedstawiono działalność sekcji CED.
EN
Clinical engineering as the specific branch of biomedical engineering is represented in the International Federation for Medical and Biological Enginee­ ring by the special Clinical Engineering Division (CED/ IFMBE) . The paper presents activity of this section.
PL
W artykule przedstawiono propozycję Clinical Engineering Division (CED/IFMBE) systemu międzynarodowej certyfikacji/rejestracji w dziedzinie inżynierii klinicznej.
EN
The article outlines the program of international certification/registration in clinical engineering developed by Clinical Engineering Division (CED/ IFMBE).
PL
W artykule przedstawiono działalność środowiska inżynierów klinicznych CED/IFMBE w zakresie ustalania międzynarodowych standardów kwalifikacji zawodowych potwierdzonych certyfikatami oraz programu ichmiędzynarodowej rejestracji.
EN
The article outlines the activities within the clini­ cal engineers environment CED/IFMBE in setting international standards of professional qualifications validated by certificates, and international registration.
PL
W artykule przedstawiono zagadnienia związane z kształceniem akademickim z zakresu inżynierii biomedycznej i zawodowym kształceniem specjalizacyjnym w dziedzinie inżynierii medycznej. Przedstawiono też główną rolę inżyniera medycznego jako specjalisty zawodu mającego zastosowanie w ochronie zdrowia.
EN
Problems related to academic education on biomedical engineering field and professional specialization on medical/clinical engineering are presented. Role of medical/clinical engineer working directly in clinical environment is described.
9
Content available remote Wykorzystanie światłowodów w inżynierii medycznej
PL
W artykule przedstawiono możliwości wykorzystania światłowodów w inżynierii medycznej. Zostały przedstawione laboratoryjne wyniki badań inteligentnego systemu monitorującego podłoże pacjenta w opiece pielęgnacyjnej. Oprócz informacji o ułożeniu pacjentów na materacu uzyskujemy w systemie monitorowania także informacje o aktualnej temperaturze pacjenta i wilgotności podłoża.
EN
The article issues the possibilities of using optical fiber in medical engineering. They were presented laboratory results of intelligent monitoring system of patients’ underlay in nursing process. The monitoring system provides information about the patients position on a mattress and also the current patients temperature and underlay humidity.
10
Content available remote Kształcenie specjalizacyjne w dziedzinie inżynierii medycznej
PL
W artykule omówiono podstawy prawne i aktualny stan wdrażania kształcenia podyplomowego w dziedzinie inżynierii medycznej.
EN
The article presents regulations and current state of the postgraduate education in medical engineering.
PL
W artykule przedstawiono działalność techniczną Komitetu Automatyki Elektroenergetycznej w latach 2010-2015 przy organizacji odczytów, seminariów i konferencji oraz redagowaniu czasopism technicznych.
EN
This article presents the technical operations of the Automation Electric Power Engineering Committee in the years 2010-2015 during organization of lectures, seminars, conferences and editing of the technical journals.
12
PL
Artykuł przedstawia wybrane aspekty szybkiego prototypowania modeli do zastosowań w medycynie i inżynierii medycznej. W pierwszej części artykułu opisane są sposoby pozyskiwania danych określających cechy geometryczne określonych części ludzkiego ciała. Następnie przedstawiono charakterystykę ogólną metod obróbki danych numerycznych w celu wykonania modelu przyrostowymi metodami szybkiego prototypowania.
EN
The article presents some aspects of rapid prototyping models for applications in medicine and medical engineering. In the first part of the article describes the methods of acquiring data defining geometrical characteristics of certain parts of the human body. This is followed by a general characterization of numerical data processing methods in order to perform incremental prototype rapid prototyping methods in terms of their application in various areas of medical engineering and medicine.
13
Content available remote Wybrane zagadnienia metod pomiarowych stosowanych w medycynie nuklearnej
PL
W artykule przedstawiono niektóre zagadnienia związane z wykorzystaniem radioizotopów w diagnostyce medycznej. Omówiono rodzaje badań izotopowych oraz przedstawiono kierunki rozwoju medycyny nuklearnej.
EN
In the paper some problems of radioisotope application in medical diagnostic have been described. Examination types and their development are discussed.
14
Content available remote Attempts at upgrading university education standards in the CEI countries
EN
Working Group of the CEI Section C 'Geodesy' on "University Education Standards" was established in 1994. The Working Group goals are focused on upgrading the education level in the field of geodesy and land surveying in the CEI countries. Paper presents the problems considered during the Working Group Symposia held at the Department of Geodesy, University of Ljubljana. The first Symposium of 1996 was devoted to the topic of "Education in GPS for Geodesy and GIS", and the second to "DGPS in Engineering and Cadastral Measurements - Education and Practice". Paper summarises the Symposia and announces The Working Group planes (A Workshop on "Education in GPS for GIS" is planned to be held in Grybów, Southern Poland, summer 1998) .
EN
The thesis addresses the problems of analysis and modelling of ultrasonic Doppler signals in vascular applications and in the assessment of fetal pseudo-respiration. A method of modelling Doppler signals of flow velocity using time-varying filtering of white noise and generation of sinusoids is presented and applied to provide signals used further in this work. The inadequacy of the AR model to the Doppler signals was found to result from their nonstationarity, implying the application of short data window lengths and low model orders. Both the objectively and subjectively selected orders fail to provide consistent simulated broad-band signals observed during the late systolic phase.The conditions of spectral analysis and estimation of diagnostic Doppler spectral indices were studied and optimised. The direct FFT, autoregressive modelling AR and Minimum Variance MV spectral estimators were studied. The mean frequency F(mean) maximum frequency F(max) and two measures of relative width SBI and INT were investigated. The data window length, defining the temporal resolution, appeared the most important factor in the analysis of the simulated carotid Doppler signal. There is a tradeoff between the errors of spectral indices resulting from the properties of spectral estimate and those resulting from insufficient temporal resolution. The first errors increase with decreasing data window length, whereas the others decrease. The optimal value of the data window length depends on the maximum acceleration of flow in the vessel of interest, e.g. in the case of a normal human common carotid artery it should be about 8 ms. Manipulating the other parameter of analysis, i.e. the maximum autocorrelation lag (MV), model order (AR) or smoothing window (FFT), allows the errors of spectral indices to be reduced. The optimal value of this parameter depends on the spectrum width, which varies throughout the cardiac cycle. In the case of MV and AR methods the errors of these indices asymptotically decrease with increasing model order/maximum autocorrelation lag, regardless of spectral width. In the case of INT, which to the greatest extent takes into account the properties of the Doppler spectrum, the MV method results in the lowest errors. The optimal conditions for the estimation of Doppler indices depend on the signal to noise ratio SNR. In the case of SNR not less than approx. 20 dB the major source of errors of Doppler indices is the bias of the spectrum, whereas for SNR lower than approx. 5 dB it is the variance, The lowest values of errors of these indices ensures the MV method. Using this method, a temporal resolution of not less than 8 ms, maximum autocorrelation lag about 15 provides a significant improvement over the results obtained with the conventional FFT method in the case of signals recorded in human common carotid artery.The experiments with carotid bifurcation models with irregular lesion surface allowed the determination of the flow phenomena (recirculation or reduced flow zones, jet-like velocity distribution), which may take place in the internal branch (ICA) distal to the irregular lesion surface and are not observed in the smooth wall model. The Doppler spectral indices are affected - the peak value of the relative spectrum width of the signal recorded in the centre of the ICA branch is significantly smaller than in smooth or mild irregularity models, whereas the measure of spectral symmetry of this signal is positive in smooth/mild irregularity models and negative in severely irregular models. The finding that the effect of the irregularity on the flow differs from that of an equivalent height stenosis is very important. The experiments indicate the possibility of inferring the presence of severe wall irregularity from the properties of the spectrum of the Doppler signal recorded distal to the irregularity. These findings are to some extent dependent on the model geometry, however, they can be used to support the evaluation of the risk of cerebral events. The investigation of ultrasonic Doppler signals of fetal activity enabled the determination of the most important features of the fetal pseudo-breathing movements to be incorporated into the detection algorithm, which are periodic, sequential and bibirectional in nature, the velocity of these movements, as well as the physiological constraints on breathing rhythm. The recommended methods are the pattern-sequence method, which resulted in about 70% correct detections and 15% false positives and the displacement method. The displacement method enables the evaluation of the distance, velocity and acceleration of the movements of fetal thorax, which may allow an objective evaluation of the fetal tone. These methods are expected to result in increased interest in the biophyscal fetal profile.
PL
Rozprawa dotyczy problematyki analizy i modelowania ultradźwiękowych sygnałów dopplerowskich w zastosowaniach naczyniowych oraz przy detekcji ruchów pseudooddechowych płodu, Zaprezentowana została metoda modelowania sygnałów dopplerowskich prędkości przepływu wykorzystująca filtrację szumu białego oraz generację sygnałów sinuosidalnych. Metodę tę zastosowano do uzyskania sygnałów wykorzystywanych w dalszej części pracy. Wykazano, że nieadekwatność modelu AR do sygnałów dpplerowskich wynika z niestacjonarności tych sygnałów, powodującej konieczność stosowania krótkich okien danych i niskich rzędów modelu. Zarówno subiektywne, jak i obiektywne kryteria doboru rzędu modelu nie pozwalają na wolną od błędów symulację sygnałów o szerokich widmach, spotykanych w późnej fazie systolicznej. Dokonano optymalizacji warunków analizy widmowej i estymacji diagnostycznych indeksów dopplerowskich. Badaniami objęto metody bezpośredniego przekształcenia FFT, modelowania autoregresyjnego AR i Minimalnej Wariancji MV oraz średnią częstotliwość widma Fmean, maksymalną częstotliwość Fmax oraz miary względnej szerokości widma SBI i NT. Określajaca rozdzielczość czasową analizy długość okna danych, okazała się być najbardziej istotnym czynnikiem w analizie symulowanego sygnału dopplerowskiego prędkości przepływu w tętnicy szyjnej. Występuje wymiana błędów wynikających z własności estymatora widma oraz z niedostatecznej rozdzielczości czasowej. Pierwsze z tych błędów rosną ze spadkiem długości okna danych, drugie zaś rosną z jej wzrostem. Optymalna długość okna danych zależna jest od maksymalnego przyspieszenia prędkości przepływu w badanym naczyniu, np. w przypadku zdrowej ludzkiej tętnicy szyjnej wspólnej powinna wynosić około 8 ms. Dobór drugiego parametru analizy, a więc maksymalnego opóźnienia funkcji autokorelacji (MV), rzędu modelu (AR) lub długości okna wygładzającego (FFT) umożliwia zmniejszenie błędów indeksów dopplerowskich. Optymalne wartości tych parametrów zależne są od szerokości widma, która ulega zmianom w cyklu serca. W przypadku metod MV i AR błędy indeksów asymptotycznie maleją ze wzrostem maksymalnego opóźnienia funkcji autokorelacji/rzędu modelu, bez względu na szerokość widma sygnału. W przypadku indeksu INT, który w największym stopniu związany jest z rozkładem widma, najmniejsze błędy zapewnia metoda MV. Optymalne warunki estymacji indeksów dopplerowskich zależne są od stosunku sygnatu do szumu SNR. Główną przyczyną błędów indeksów jest obciążenie estymatora widma, jeśli SNR jest nie mniejszy niż ok. 20 dB, natomiast dla SNR poniżej ok. 5 dB główne źródlo błędów stanowi wariancja estymatora widma. Najniższe błędy indeksów zapewnia metoda MV. Jej użycie przy dlugości okna danych odpowiadającej 8 ms, maksymalnym opóźnieniu funkcji autokorelacji około 15 zapewnia znacznie mniejsze błędy indeksów niż uzyskiwane przy użyciu tradycyjnej metody bezpośredniego przeksztalcenia Fouriera w przypadku sygnałów pochodzących z ludzkiej tętnicy szyjnej wspólnej. Eksperymenty w modelach bifurkacji tętnic szyjnych z nierównomierną powierzchnią złogu pozwoliły określić zjawiska występujące w rozkładzie prędkości (przepływ wsteczny lub strefa ograniczonego przepływu, wypłaszczony rozklad prędkości), które mogą wystąpić w gałęzi tętnicy wewnętrznej (ICA) ponizej nierównomierności, a które nie występują w modelu o ścianie gladkie, Indeksy dopplerowskie także ulegają zmianie - wartość maksymalna miary względnej szerokości widma INT sygnału zarejestrowanego w środkowej części modelu jest znacznie niższa w przypadku silnej nierównomierności niż w przypadku ściany gladkiej lub nierównomierności łagodnej, natomiast miara symetrii widma tego sygnału jest ujemna w modelach o silnej nierównomierności i dodatnia w modelach gładkich lub z łagodną nierównomiemością. Eksperymenty te pozwalają stwierdzić, że na podstawie własności widma sygnału dopplerowskiego można wnioskować o nierównomierności ściany powyżej miejsca pomiaru, Wyniki, choć w pewnym stopniu zależne od własności badanego modelu bifurkacji, mogą zostać wykorzystane przy ocenie ryzyka wystąpienia symptomów mózgowych. Studia nad dopplerowskimi sygnałami aktywności ruchowej płodu pozwoliły określić najistotniejsze cechy ruchów pseudooddechowych, które powinien uwzględniać algorytm detekcji tych ruchów. Są to okresowość i sekwencyjna zmiana kierunku oraz prędkość tych ruchów , a także fizjologiczne ograniczenia rytmu oddechowego. Zaproponowano metodę sekwencji i porównania z wzorcem, która zapewnia poprawną detekcję około 70% cykli oddechowych przy około 15% detekcji nieprawidłowych oraz metodę analizy przemieszczeń klatki piersiowej płodu. Metoda analizy przemieszczeń umożliwia określenie zasięgu, szybkości i przyspieszenia ruchu, co może pozwolić na obiektywizację oceny tonusu płodu. Metody te powinny zaowocować zwiększeniem wykorzystywania profilu biofizycznego płodu.