Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 9

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  implanty kostne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Every bone implant to work correctly after implantation needs to integrate with the surrounding bone. To enhance such a process, called osseointegration, various techniques of implant surface modification emerged. One of the approaches is based on the deposition of nano- and submicron materials on the implant surface. This paper presents a solution blow spinning process for producing poly-L-lactic acid (PLLA)/ceramic fibrous composites designed to be deposited directly onto orthopaedic implants prior to implantation to increase osseointegration. We produced plain PLLA fibrous materials for comparison, and fibrous composite materials with 𝛽-tricalcium phosphate (𝛽TCP), hydroxyapatite nanoparticles (nHAp) and hydroxyapatite nanoparticles modified with lecithin (nHAp-LE). We performed the structural analysis of produced materials with scanning electron microscopy, gravimetric determination of porosity, and water contact angle measurement. We also used infrared spectroscopy, Alizarin Red S staining, and cytotoxicity evaluation to conclude that PLLA/nHAp-LE composite material shows the most promising properties to be applied as surface modification of bone implants. To visualise fibrous composite deposition on implants, we used two models: titanium plate and stainlesssteel bolt. Thus, we showed that the solution blow spun materials can be used for surface modification of orthopaedic implants.
2
Content available remote Materiały stosowane do wytwarzania implantów kości
PL
Materiały stosowane do wytwarzania implantów kostnych muszą być biokompatybilne, nietoksyczne, bioaktywne oraz wykazywać odpowiednie właściwości mechaniczne, takie jak wytrzymałość na ściskanie, na zginanie oraz sztywność i twardość. Gama stosowanych materiałów jest bardzo szeroka, obejmuje metale, polimery, ceramikę oraz ich kompozyty. Każdy z tych materiałów ma swoje mocne i słabe strony. Praca stanowi przegląd materiałów stosowanych do wytwarzania implantów kości, ze szczególnym uwzględnieniem oferty rynku polskiego.
EN
A brief review, with 24 refs., of metallic, ceramic, polymeric and composite materials.
PL
Tytan i jego stopy ze względu na szczególne właściwości fizyczne, chemiczne oraz dobrą biozgodność w środowisku ludzkich komórek i tkanek znajdują coraz szersze zastosowanie w medycynie. Jednak, chociaż w mniejszym stopniu niż inne biomateriały metaliczne np. stale austenityczne i stopy CoCrMo, stosowanie tego materiału na implanty długookresowe ograniczają stosunkowo niska odporność na zużycie przez tarcie i przechodzenie składników stopu do otaczającego implant środowiska biologicznego. Stąd też podstawowym kierunkiem wyeliminowania tych ograniczeń są metody inżynierii powierzchni, umożliwiające kształtowanie mikrostruktury, składu fazowego i chemicznego, topografii powierzchni, a więc właściwości użytkowych stopów tytanu, w tym biologicznych. W artykule przedstawiono strukturę i właściwości warstw typu Ti3P + Ti2Ni wytwarzanych na stopie tytanu Ti6A14V w aspekcie zastosowania na implanty kostne.
EN
Titanium and its alloys regarding to their physico-chemical properties and good biocompatibility with human tissues are widely applied in medicine. Their long-term use as implant material is limited by low wear resistance and releasing the elements from the alloy to the surrounding implant environment. However this limitation is of lower degree than for e.g. an austenitic stainless steel or CoCrMo alloy. Surface engineering methods are applied to improve biomaterial useful properties of titanium alloys and their biocompatibility. These methods are aimed to modify microstructure, phase and chemical composition, and surface topography. The paper presents structure and properties of the surface layers Ti3P + Ti2Ni type produced on Ti6A14V alloy for bone implants application in medicine.
5
PL
Główną wadą implantów na bazie stopów tytanu przeznaczonych dla chirurgii kostnej, wymagających długoczasowej stabilności, jest niedopasowanie struktury powierzchni implantu do otaczającej tkanki. Przy implantach stawu biodrowego może to prowadzić do aseptycznego obluzowania się endoprotezy. Funkcjonalne dopasowanie implantu jako otwarto-porowatej struktury, która obejmuje cały implant lub tylko powierzchnię, może sprzyjać procesowi wzrostu tkanki kostnej w pory implantu lub prowadzić do jego mechanicznego zakotwiczenia. W pracy przedstawiono wyniki badań nad spiekaniem proszków Ti-6Al-4V o wielkości ziaren 35mim. Proces spiekania prowadzono w gradiencie temperatury w atmosferze gazu obojętnego. Metoda ta pozwalała otrzymywać mikrostruktury o otwartych porach, które mogą być wykorzystane do konstrukcji implantów ze stopów tytanu o podwyższonej trwałości i zdolności do fiksacji z tkanką kostną.
EN
The main reasons for the failure of titanium based alloy bone implants requiring long term stability is the incompatibility of the implant's surface structure and the growth rate of natural bone tissue. In the case of a hip joint endoprosthesis, this leads to an aseptic loosening of the endoprosthesis. Functional adaptation of the implant as an open pored structure, which either extends over the whole implant or exists only on its surface, presents the possibility for the bone tissue to grow into the implant and provide mechanical anchorage for the implant in the bone. In the present work, the results of investigations and the sintering process using 35mim size powder grains of the alloy Ti-6Al-4V are presented. A sintering process was chosen as a manufacturing method using a selected temperature gradient and an inert scavenging gas. This method of manufacture produced open pored structures whose properties can be transferred to a larger group of applications of metallic long term implants for osteosynthesis.
PL
W ramach przeglądu literaturowego przedstawiono podstawy teoretyczne i osiągnięcia w badaniach implantów kostnych, przede wszystkim zaś materiały polimerowe stosowane na implanty wraz z kryteriami wyboru odpowiednich polimerów. Kryteria te obejmują budowę polimeru, przebieg procesu biodegradacji, porowatość, właściwości mechaniczne oraz właściwości powierzchniowe. Omówiono także modyfikację powierzchni implantów kostnych białkami. Część dotycząca wyników prac własnych zawiera wyniki oceny adhezji komórek kostnych (osteoblastów) na różnych rodzajach biomateriałów stosowanych jako porowate implanty kostne. Zastosowano nową metodę sposobu postępowania w takiej ocenie, przedstawioną na schemacie A. Zbadano kąt zwilżania otrzymanych powierzchni (CA), a także przeżywalność komórek po tygodniowej inkubacji na podstawie pomiaru aktywności enzymu dehydrogenazy bursztynianowej (test XTT) oraz aktywności fosfatazy alkalicznej (test ALP). Badania prowadzono w 11 seriach pomiarowych (podział ze względu na rodzaj podłoża). Najlepsze wyniki uzyskano w przypadku powierzchni z dekstranem, jak również układów dekstran + poli(kwas akrylowy) (PAA), dekstran + Ca(NO3)2 bądź dekstran + PAA + Ca(NO3)2. Nie znaleziono jednoznacznej korelacji pomiędzy wynikami testów biologicznych a charakterem hydrofilowym bądź hydrofobowym podłoży polimerowych.
EN
In a literature review the theoretical fundamentals and achievements in osseous implants' investigations have been presented. Especially polymeric materials used in implants were discussed as well as the criteria of the proper polymers choice. These criteria cover the structure of a polymer, porosity, mechanical and surface properties and biodegradation process course. Modification of osseous implant surface with proteins has been also discussed. The part concerning the own research contains the results of evaluation of bone cells' (osteoblasts) adhesion to various types of biomaterials, used as porous osseous implants. A new way of evaluation, presented in Scheme A, was used. Contact angle values (CA, Fig. 1) of the surfaces obtained were measured. Also viability of cells after one-week incubation was investigated basing on the measurements of activity of enzymes of succinate dehydrogenase (XTT Test, Fig. 2) or alkaline phosphatase (ALP Test, Fig. 3). 11 series of measurements differing in the substrate type were done. The best results have been obtained for the surfaces with dextran as well as with the systems: dextran + poly(acrylic acid) (PAA), dextran + Ca(NO3)2 or dextran + PAA + Ca(NO3)2. We did not find an unambiguous correlation between biological tests results and hydrophylic or hydrophobic character of polymeric substrate.
PL
Przedstawiono wyniki badań wstępnych mocowania biomechanicznego w kości implantów kompozytowych na bazie proszku Co-Cr-Mo, wykonanych w trzech wariantach: ze stopu litego, spieku z proszku oraz spieku z proszku z 10% dodat­kiem Bioszkla S-2. Badania przeprowadzono na trzech kastrowanych kozłach mieszańcach w wieku około jednego roku, pochodzących z tego samego stada. Implantami uzupełniono ubytki trzonu kości piszczelowej. Badania RTG wykonane po dwóch tygodniach od zespolenia wskazują na obecność kostniny, pojawiającą się wokół implantów. Dalsze badania mecha­niczne i mikroskopowe pozwoliły na ocenę jakości połączenia wszczepu z kością.
EN
The paper presents research relating osteointegration of porous implants made from Co-Cr-Mo, executed in three variants: from solid alloy, porous Co-Cr-Mo sintered compact and porous composite with 10% addition of bioactive-glass type S-2. The research has been made on three castrated goats in age of about one year, from this oneself herds. Decrease of shaft of tibia bone has been supplemented by implants. RTG research has been executed after two weeks from junctions showed bone callus appearing all around implants. The postmortem mechanical and microscopic investigations has permitted for estimation of quality of connection implants with bone.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.