Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 40

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  impedance measurement
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available remote Quasi-balanced method of measuring the dielectric loss factor
EN
Quasi-balanced methods of impedance measurements are generally intended for measuring a single component of an unknown impedance. The article presents a quasi-balanced method of measuring the dielectric loss factor (tan δ), which was implemented as a virtual instrument in LabVIEW environment.
PL
Quasi-zrównoważone metody pomiaru impedancji są generalnie przeznaczone do pomiaru pojedynczego składnika o nieznanej impedancji. W artykule przedstawiono quasi-zrównoważoną metodę pomiaru współczynnika strat dielektrycznych (tan δ), która została zaimplementowana jako przyrząd wirtualny w środowisku LabVIEW.
PL
Artykuł powstał na podstawie pracy dyplomowej zrealizowanej w Wojskowej Akademii Technicznej. Wyniki opisujące zagadnienia pomiaru impedancji w sieciach elektroenergetycznych wysokiego napięcia pozwoliły na analizę możliwości sfałszowania pomiarów w wyniku powstania zakłóceń. Przedstawiono przebiegi napięć i prądów podczas zwarcia bezpośredniego pośredniego oraz podczas pracy dwóch źródeł na zwarcie, a także przebiegi impedancji podczas kołysań mocy.
EN
The article is based on the diploma thesis carried out at the Military University of Technology. The results describing the impedance measurement issues in high voltage power networks allowed for the analysis of the possibility of falsifying the measurements as a result of disturbances during normal and fault operations. Voltage and current waveforms during a direct indirect short-circuit, during operation of two sources on short-circuit and impedance waveforms during power swings were presented.
PL
W artykule wskazano na istotny problem niejednoznaczności pomiaru impedancji pętli zwarciowej (IPZ) w obwodach zasilanych z zasilaczy UPS typu online (double conversion AC-DC-AC). Poprawnie zmierzona wartość impedancji pętli zwarciowej, na podstawie której wyznacza się spodziewany prąd zwarciowy, jest kluczowa w ocenie skuteczności ochrony przeciwporażeniowej przez samoczynne wyłączenie zasilania i dopuszczeniu instalacji elektrycznej do eksploatacji. Wykonanie prób pomiarów impedancji pętli zwarciowej w obwodach zasilanych z UPS zgodnie z przyjętą metodyką, w różnych trybach pracy zasilacza, pozwoliło na zdefiniowanie zasad pomiaru, które ograniczają błąd w ocenie skuteczności ochrony przeciwporażeniowej przez samoczynne wyłączenie zasilania. Na podstawie przeprowadzonych prób i analiz zaproponowano autorski algorytm wyznaczania impedancji pętli zwarciowej w obwodach zasilanych z UPS-a oraz opracowano i zweryfikowano w praktyce procedurę sprawdzania skuteczności ochrony przeciwporażeniowej przez samoczynne wyłączenie zasilania w obwodach zasilanych z UPS.
EN
The paper indicates a significant problem of uncertainty of Fault Loop Impedance (FLI) measurement in circuits powered from UPS (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers for operation. To define the principles of FLI measurement, several hundred measurements of the short-circuit loop impedance in the circuits fed by the UPS, in various UPS operation modes and with various FLI instruments, were made, which allowed for the definition of measurement rules that reduce the error in assessing the effectiveness of protection against electric shock by automatic disconnection of supply. Based on the analysis of voltage and current waveforms recorded during the real short-circuit tests in the circuit fed by the UPS, a proprietary algorithm for determining the short-circuit loop impedance has been proposed.
PL
W artykule wskazano na istotny problem niejednoznaczności pomiaru impedancji pętli zwarciowej (IPZ) w obwodach zasilanych z zasilaczy UPS typu online (double conversion AC-DC-AC). Poprawnie zmierzona wartość impedancji pętli zwarciowej, na podstawie której wyznacza się spodziewany prąd zwarciowy, jest kluczowa w ocenie skuteczności ochrony przeciwporażeniowej przez samoczynne wyłączenie zasilania i dopuszczeniu instalacji elektrycznej do eksploatacji. Wykonanie prób pomiarów impedancji pętli zwarciowej w obwodach zasilanych z UPS zgodnie z przyjętą metodyką, w różnych trybach pracy zasilacza, pozwoliło na zdefiniowanie zasad pomiaru, które ograniczają błąd w ocenie skuteczności ochrony przeciwporażeniowej przez samoczynne wyłączenie zasilania. Na podstawie przeprowadzonych prób i analiz zaproponowano autorski algorytm wyznaczania impedancji pętli zwarciowej w obwodach zasilanych z UPS-a oraz opracowano i zweryfikowano w praktyce procedurę sprawdzania skuteczności ochrony przeciwporażeniowej przez samoczynne wyłączenie zasilania w obwodach zasilanych z UPS-ów.
EN
The paper indicates a significant problem of uncertainty of Fault Loop Impedance (FLI) measurement in circuits powered from UPS (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers for operation. To define the principles of FLI measurement, several hundred measurements of the short-circuit loop impedance in the circuits fed by the UPS, in various UPS operation modes and with various FLI instruments, were made, which allowed for the definition of measurement rules that reduce the error in assessing the effectiveness of protection against electric shock by automatic disconnection of supply. Based on the analysis of voltage and current waveforms recorded during the real short-circuit tests in the circuit fed by the UPS, a proprietary algorithm for determining the short-circuit loop impedance has been proposed.
EN
Verification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5-20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits with RCDs usually use an extremely low value of current (lower than 15 mA), which in many cases it is not acceptable in terms of the measurement accuracy. This paper presents a method of earth fault loop impedance measurement in 3-phase circuits, without nuisance tripping of RCDs – the concept of measurement, the meter structure and the experimental validation. The nuisance tripping is avoided in spite of the use of measuring current value many times higher than that of the rated residual current of RCDs. The main advantage of the proposed method is the possibility of creating values of measuring current in a very wide range, what is very important with regard to accuracy of the measurement.
PL
W artykule przedstawiono budowę oraz wyniki badań wybranych parametrów fizycznego modelu programowalnego referencyjnego źródła napięcia stałego. Źródło to może być wykorzystane do realizacji cyfrowego generatora napięcia sinusoidalnego o dużej rozdzielczości nastawy amplitudy według jednej z zaprezentowanych w artykule koncepcji. Oprócz wyników badań samego źródła, w artykule przedstawiono także wybrane wyniki badań dwufazowego generatora zrealizowanego na bazie komercyjnej karty PXI z zastosowaniem opracowanego źródła.
EN
The article presents the structure and test results of selected parameters of the physical model of the programmable reference DC voltage source. The source can be used to implement a digital sinewave voltage generator with a high-resolution amplitude setting according to one of the concepts presented in the article. In addition to the research of the DC voltage source, the article also presents selected research results of the twophase generator created on the basis of a commercial PXI card and the developed source.
EN
The paper concerns the RC equivalent circuit of electrochemical cell with the impedance changed during the experiment. The model was constructed using the digital potentiometers controlled by the microcontroller. This solution allows to control the model impedance by the software means. By creating adequate changes of the impedance spectrum as a time function, the different impedance measurement method can be tested to find out the the limitation of each method as well as to test the instrumentation.
PL
Przedmiotem artykułu jest model układu elektrochemicznego, którego impedancja jest zmieniana w czasie w sposób kontrolowany programowo. Do konstrukcji modelu wykorzystano potencjometry cyfrowe sterowane mikrokontrolerem. Odpowiednie ukształtowanie zmian widm impedancyjnych w funkcji czasu (impedancjogramów) pozwala na ustalenie ograniczeń różnych metod pomiaru impedancji.
8
Content available remote A two-phase sine wave generator dedicated for impedance comparison systems
EN
The hardware idea and experimental studies of a two-phase sine wave generator intended for use in an impedance metrology are described. The scope of the study involved determining the parameters of the generator that significantly affect its applicability in precise impedance measurements, i.e.: amplitude and phase stability of generated sinewave signals, as well as the total harmonic distortion and the spurious-free dynamic range, which determine their dynamic properties.
PL
W artykule przedstawiono rozwiązanie układowe oraz wyniki badań eksperymentalnych dwufazowego generatora sygnałów sinusoidalnych przeznaczonego do stosowania w metrologii impedancyjnej. Zakres badań obejmował wyznaczenie parametrów generatora, które w istotny sposób wpływają na jego możliwości aplikacyjne w układach do precyzyjnego porównywania impedancji, t.j.: stabilność amplitudy i fazy generowanych sygnałów sinusoidalnych oraz współczynnik zawartości harmonicznych i zakres dynamiczny bez zniekształceń, określające ich właściwości dynamiczne.
EN
The paper presents an implementation of the ellipse-fitting algorithm in the impedance measurement system based on DAQ card equipped with FPGA chip. The method implementation was tested by simulation means as well as experimentally in the designed and presented measurement system. Finally, the limit values of sampling parameters which assures satisfying accuracy were given.
PL
W artykule omówiono implementację algorytmu ellipse-fitting w systemie pomiarowym impedancji na bazie karty DAQ z układem FPGA. Implementacja metody została przebadana zarówno symulacyjnie jak również eksperymentalnie w zaprezentowanym systemie. Przedstawiono minimalne wartości parametrów próbkowania dla zapewnienia akceptowalnej dokładności.
EN
The paper presents an automatic system for measuring the moisture content of wood on the basis of loss factor tanδ. The instrument is based on a structure of the non-bridge, quasi – balanced circuit implemented in a program way. The virtual measuring system uses the data acquisition board NI USB-6251 from National Instruments and LabVIEW environment. The preliminary results of experimental studies were compared with the results of the LCR meters Hioki 3522, MOTECH MIC-4090 and meter of wood humidity Powerfix HG00384C.
EN
The paper presents the idea of the possibility of implementing automatic virtual instrument using the quasi ˗ balanced method to measure the active component of impedance (resistance). The system is based on the structure of a non-bridge quasi-balanced circuit. The process of balancing is automatically performed. This meter has been built based on the data acquisition board NI USB-6251 from National Instruments and programming environment LabVIEW. Signal processing is made in an algorithmic way. The measurement of the phase angle is based on short-term Fourier transform. The results of preliminary experimental research are presented in the paper.
12
Content available remote Cyfrowy mostek impedancji na bazie komercyjnej karty akwizycji danych
PL
Przedstawiono koncepcję cyfrowego automatycznego mostka impedancji o wysokiej dokładności zbudowanego w oparciu o komercyjną kartę akwizycji danych. Podano wstępne wyniki komparacji wzorców impedancji wykonanych za pomocą opracowanego przez autorów modelu fizycznego mostka.
EN
The concept of a high accuracy digital automatic impedance bridge based on a commercial multifunction data acquisition card is presented. The authors developed a physical model of the bridge which was used to comparisons of impedance standards. The paper contains the preliminary results of selected comparisons.
PL
W pracy zaproponowano i przetestowano nową koncepcję woltomierza wektorowego z wykorzystaniem cyfrowego przetwarzania sygnałów. Obliczenia prowadzone są sukcesywnie z akwizycją próbek sygnałów pomiarowych, bez gromadzenia ich w pamięci, przy zachowaniu wysokiej częstotliwości próbkowania. Wymaganej mocy obliczeniowej dostarcza układ FPGA. Do obliczania transformaty użyto pamięci wzorca sinusa umieszczonej w układzie FPGA oraz 4 identycznych bloków pracujących równolegle: mnożnika i akumulatora.
EN
In the paper, a new concept of a vector voltmeter for the impedance spectroscopy analyzer is proposed. The voltmeter uses the digital signals processing method for determination of orthogonal parts of measurement signals. The Discrete Fourier Transform calculations are performed “on-the-fly”, successively with acquisition of measurement signals samples, without the need of storing samples in a memory, while assuring the high sampling frequency. The required processing power was supplied by a Spartan 3 FPGA chip. For Fourier transform calculation, the sine pattern stored in the FPGA and 4 identical block sets, a multiplier and an accumulator, were created by Core Generator and used. The previously used vector voltmeter solution was based on a DSP processor with additional circuits (CPLD chip, memories, buffers) and was replaced by a single FPGA chip solution. The selected FPGA offers enough resources and allows reducing the number of additional external components. The prototype of the proposed solution was realized using the FPGA evaluation board with an added module of A/D and D/A converters (Fig. 3). The analyzer was realized in a form of a virtual instrument, the control panel was created by software. The tests were performed on the reference resistors (Figs. 8 and 9). The prototype proved the concept. However, it requires further works. It is necessary to look for a more energy-efficient FPGA chip as well as to optimize the project in terms of powerconsumption minimization.
EN
The paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was then practically verified in a constructed simple impedance measurement instrument based on a PSoC (Programmable System on Chip). The obtained calculation simplification recommends the method for implementation in simple portable impedance analyzers destined for operation in the field or embedding in sensors.
EN
The authors paid particular attention to the problem of antenna impedance measurements in the RFID technique. These measurements have to be realized by using two ports of a vector network analyzer and dedicated passive differential probes. Since the measurement process and estimated parameters depend on the frequency band, operating conditions, type of the system component and antenna designs used, appropriate verification of the impedance parameters on the basis of properly conducted experiments is a crucial stage in the antenna synthesis of transponders and read/write devices. Accordingly, a systematized procedure of impedance measurements is proposed. It can be easily implemented by designers preparing antennas for different kinds of RFID applications. The essence of indirect measurements of the differential impedance parameters is discussed in details. The experimental verification has been made on the basis of a few representative examples.
EN
Nano fibred materials ensure high porosity and relative surface area of separators. These parameters are important to improve ionic mobility between electrodes and ensure sufficient electrolyte volume in battery. These advantages make electrospinning very promising method of nanofibrous separators mass production. In this paper are described electrospinning fabrication process and discussed results of separator’s electric and electrochemical properties measurements compared with Celgard 3401.
PL
Nanostruktura materiałów wykorzystywanych jako separatory zapewnia ich wysoką porowatość, a co za tym idzie dużą powierzchnię właściwą. Parametry te są ważne w kontekście podwyższenia mobilności jonów (Ion mobility) i zagwarantowania wystarczającej ilości elektrolitu w baterii. Korzyści te pozwalają upatrywać w elektro wirowanie bardzo obiecującą metodę masowej produkcji separatorów z nanowłókien. W niniejszym artykule opisany zostaje proces produkcji separatorów. Omawia się również wyniki pomiarów elektrycznych i elektrochemicznych w porównaniu do Celgrad 3401.
PL
W pracy przedstawiono koncepcję i realizację układu do pomiaru dobroci cewek rzeczywistych wykorzystującego quasizrównoważoną metodę pomiaru składowych impedancji. Do pomiaru dobroci niezbędne jest wyznaczenie składowej czynnej i składowej biernej badanej impedancji. Dodatkowo składową bierną przybliża się modułem impedancji. Przedstawiona metoda wykorzystuje przetwarzanie programowe sygnałów pomiarowych oraz detekcję fazoczułą realizowaną algorytmicznie.
EN
In this paper an idea and realization of the system for quality factor measurements of real coils has been presented. Described system uses quasi-balanced method of impedance components measurements. To take Q factor measurements of the coil it's necessary to determine it's active and reactive impedance components. Furthermore the reactive component is approximated by impedance module. Presented method, which is based on algorithmic phase detection, allows easy virtualization.
EN
The paper presents the concept of a measurement system for the calibration of AC standard resistors with low resistance values and the selected research results of a commercial sampling module constituting a key element of the system which is being developed. Among others there is presented the results of a 24-hour stability study of the analog-to-digital processing paths of a sampling module.
PL
Przedstawiono koncepcję systemu pomiarowego do wzorcowania rezystorów wzorcowych prądu przemiennego o małych wartościach rezystancji oraz wybrane wyniki badań komercyjnego modułu próbkującego stanowiącego podstawowy element opracowywanego systemu. Między innymi przedstawiono wyniki badań 24-godzinnej stabilności torów przetwarzania analogowo-cyfrowego modułu próbkującego.
19
PL
W pracy podjęto próbę zbadania przydatności układu AD5933 do współpracy z czujnikami impedancyjnymi o charakterze pojemnościowym. Nakreślono główne ograniczenia przetwornika AD5933 wynikające z jego konstrukcji. Porównano wyniki pomiarów modułu impedancji dwójników równoległych RC otrzymane za pomocą układu AD5933 i miernika HP4284A. Wyniki badań wskazują, że błąd pomiaru modułu impedancji maleje wraz z zawężaniem przedziałów wartości mierzonych. Przy dopuszczalnym błędzie pomiaru sięgającym kilku procent, przetwornik AD5933 może być zastosowany w urządzeniu docelowym.
EN
In the paper there is made an attempt to verify the suitability of using the AD5933 impedance converter with capacitive-type impedance sensors. For this reason the levels of measurement errors of an impedance varying in a wide range were determined. The structure (Fig. 1) and the principle of operation of the AD5933 converter are presented. There are described the main limitations resulting from its construction and the available current measurement in the AD5933 converter (without simultaneous measurement of voltage), which forces making the calibration measurement before the real measurement of an unknown impedance. The accuracy of the impedance modulus measurement of chosen parallel RC circuits by means of the AD5933 was examined by comparison with the results obtained with use of the precise HP4284A LRC meter. The values of resistance and capacitance in the exemplary circuits were selected in such a way that the resultant impedance modulus changed in the possibly wide range along with changes of the measurement frequency. The results of the tests made on three chosen RC circuits are presented in the text (Figs. 2 - 4). Fig. 5 shows the impedance modulus relative error. Based on the findings of the tests one can conclude that the impedance measurement error decreases as the ranges of the measured values become narrower. The AD5933 impedance converter can be used in a measuring system when assuming that the measurement error of a few percent is acceptable.
PL
W artykule przedstawiono układ do pomiaru impedancji elektrycznej ceramicznych przetworników piezoelektrycznych w zakresie częstotliwości od 10 kHz do 100 kHz. Układ ten stanowi ulepszenie układu przedstawionego w publikacji [1]. Zwiększono znacznie dokładność pomiaru poprzez minimalizację wpływu niepożądanej pojemności wejściowej karty pomiarowej. Ponadto, zastosowano układ automatycznej zmiany wartości rezystancji wzorcowej w celu dodatkowej minimalizacji błędu pomiaru oraz zwiększenia równomierności jego rozkładu w całym zakresie pomiarowym.
EN
In the paper the circuit for ceramic piezoelectric transducer impedance measurements in the frequency range of 10 kHz to 100 kHz has been presented. This circuit is a modification of the measurement circuit presented in [1]. The measurement accuracy has been greatly increased through minimization of the data acguisition card input capacitance influence. Moreover, a circuit for automatic selection of the reference resistance value has been used in order to additionally minimize the measurement error and to increase the uniformity of its distribution over the entire measurement range.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.