Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  imbibition process
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The process of liquid imbibition occurs non-uniformly in nonwoven sorptive materials. It is a result of complexity and nonhomogeneity of sorbent structure. The voids between fibers in nonwoven material appear in a form of parallel-channels’ system. The width between fibers (basic channel) was assumed as equal to the average fiber diameter, df, and the width of parallel channel is 2, 5, 10, and 20 times greater. The simulations of imbibition process were performed in Comsol Multiphysics 5.0 using the Laminar Two-Phase Flow, Level-Set application mode. The obtained results for two-channel systems depend strongly on the width between fibers. The increasing of width caused the prolongation of time needed to reach the assumed maximal height. This phenomenon can be explained by changes of pressure in the channel-reservoir boundary. Additionally, the obtained results provided the data for tracing imbibition processes during their start-up phase.
PL
W przypadku włókninowych materiałów sorpcyjnych proces nasiąkania cieczą następuje nierównomiernie. Wynika to ze złożonej i nichomogenicznej struktury sorbentu. W pracy zaprezentowano wyniki badań szybkości procesu imbibicji w zależności od rozmiarów równoległych kanałów reprezentujących puste strefy w strukturze sorbentu. Przyjęto, że szerokość podstawowego kanału jest równa średniej średnicy włókna, a szerokość kanału równoległego jest 2, 5, 10 i 20 razy większa. Wykonano numeryczne symulacje procesu imbibicji korzystając z programu Cosmol Multiphysics 5.0 stosując moduł umożliwiający śledzenie przepływów dwufazowych - Laminar Two-Phase Flow, Level-Set. Wyniki symulacji wykazały wpływ stosunku szerokości równoległych kanałów na prędkość wznoszenia się w każdym z nich. Zjawisko to można wyjaśnić jako wywołane zmianami wartości ciśnienia na wlocie do systemu kanałów. Ponadto wyniki symulacji dostarczyły danych przydatnych do śledzenia procesów imbibicji w ich początkowej fazie.
EN
Tested two-phase liquids represented stabilized oil-in-water emulsions with dispersed phase concentrations of 10 vol.%, 30 vol.% and 50 vol.%. During the experiments, correlations between the level of medium saturation and the height of emulsion front and between the initial concentration of dispersed phase and process time were defined. The porous media oversaturation was observed mostly for him < 0.04 m due to a layer formation on the external surface of sorbent sample. Moreover, the level of saturation also varied with time, but the registered sorbent saturation level of 65+85% was obtained within the first 600 s. For equilibrium time, i.e. 900 s, the lowest saturation level equal to 0.88 was observed for 10% emulsion and the height range of 0.04 m < hjm < 0.06 m. The sorbents imbibed with 50% emulsion had the highest level of saturation. Changes of saturation with time were described by the appropriate equation.
PL
Badane układy dwufazowe były stabilnymi emulsjami o stężeniach fazy rozproszonej: 10, 30, 50% obj. Określono zależności między stopniem saturacji a poziomem nasycenia oraz między początkowym stężeniem fazy rozproszonej a czasem trwania procesu. Stwierdzono, ze stopień saturacji może być większy od 100% dla wysokości him ≤ 0,04 m w wyniku formowania się warstwy cieczy na zewnętrznej powierzchni sorbentu. Stopień saturacji zmieniał się w czasie, ale wartości 65÷85% uzyskano już po 600 s. Dla czasu równowagowego 900 s najniższy poziom saturacji równy 0,88% obserwowano dla emulsji o stężeniu 10% dla wysokości 0,04 m ≤ him ≤ 0,06 m. Najwyższy poziom saturacji uzyskano dla emulsji 50%. Zaproponowano równanie określające zmiany saturacji od czasu.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.