Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  hydroxyapatite coatings
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The surface condition of an implant has a significant impact on response occurring at the implant-biosystem border. The knowledge of physical-chemical and biological processes allows for targeted modification of biomaterials to induce a specified response of a tissue. The present research was aimed at development of technology composing of obtaining the nanotube oxide layers on a porous titanium alloy Ti13Nb13Zr, followed by the deposition of phosphate coating. The porous substrate (porosity about 50%) was prepared by a selective laser melting of the Ti13Nb13Zr powder with the SLM Realizer 100 equipment. The nanotubular oxide layers were fabricated by electrochemical oxidation in H3PO4 + 0.3% HF mixture for 30 min. at a constant voltage of 20V. The calcium phosphate coatings were formed by the electrochemically assisted deposition (ECAD). The presence of nanotubular oxide layers with their internal diameters ranging from 30 to 100 nm was observed by SEM (JEOL JSM-7600F). The nanotubes have dimensions that facilitated the deposition of hydroxyapatite.
PL
Implanty na bazie stopów tytanu są z powodzeniem stosowane w ortopedii i dentystyce. W celu poprawienia integracji implantu z kością wykonano porowatą, hydroksyapatytową powłoką na stopie Ti-6Al-7Nb techniką elektrolityczno-plazmowego utleniania. Otrzymaną powłokę poddano analizie pod kątem mikrostruktury, chropowatości i składu fazowego. Dodatkowo wykonano wstępne badania in vitro.
EN
Titanium based implants are used both in orthopedics and dentistry. For better integration of implant with bone porous, hydroxyapatite crystals containing coating was deposited on Ti-6Al-7Nb alloy by microarc oxidation process. Microstructure, roughness and phases composition of the coating was analyzed. Moreover preliminary in vitro studies were done.
PL
Przedstawiono sposób nakładania powłok hydroksyapatytowych na porowaty stop tytanu Ti13Nb13Zr za pomocą osadzania biomimetycznego poprzez zanurzenie materiału w przesyconym symulowanym płynie fizjologicznym. Powłoka hydroksyapatytowa została osadzona na nanorurkową warstwę tlenkową, otrzymaną w wyniku utleniania elektrochemicznego w roztworze zawierającym jony fluorkowe.
EN
Hydroxyapatite coating on porous alloy Ti13Nb13Zr deposited by biomimetic deposition method by immersing in a supersaturated simulated body fluid has been presented. Hydroxyapatite coating was deposited on nanotubular oxide layer, which was obtained by electrochemical oxidation in a solution containing fluoride ions.
PL
Powłoki hydroksyapatytowe nanoszone są na powierzchnie metalicznych implantów długotrwałych (endoprotezy stawowe i wszczepy stomatologiczne) za pomocą takich technologii, jak: osadzanie metodą CVD, PVD, elektroforeza, osadzanie elektrochemiczne, metoda zol-żel, natryskiwanie plazmowe, rozkład termiczny. Podstawowym, stosowanym na skalę przemysłową, sposobem nanoszenia powłok HAp na powierzchnię implantów jest technika plazmowa wykorzystywana od 1985 roku. Zastosowanie tej techniki prowadzi do uzyskiwania warstw hydroksyapatytowych o grubości w zakresie od 40÷300 um. Niewystarczające własności użytkowe powłok HAp uniemożliwiają zastosowanie ich w elementach przenoszących duże obciążenia. Jak dowiodły badania, głównym mankamentem implantu kompozytowego z wykorzystaniem HAp jest strefa połączenia powłoka-podłoże. Jako jeden ze sposobów poprawy niewystarczających własności wytrzymałościowych powłok bioceramicznych HAp zaproponowano modyfikowanie jej dodatkiem fazy cyrkonowej. Jak wynika z analizy widma FTIR, brak jest oznak uwalniania jonów OH- ze struktury hydroksyapatytu, co wyklucza obecność następujących faz: OAp lub OHAp. Ponadto ujawniono obecność grupy PO4 3- pochodzącej od fazy a-TCP. Modyfikacja składu chemicznego powłok bioceramicznych dodatkiem fazy cyrkonowej oraz odpowiedni dobór parametrów otrzymywania powłok metodą natryskiwania plazmowego pozwoliły na osiągnięcie dużej skuteczności w zakresie ochrony podłoża przed korozją w środowisku płynów ustrojowych.
EN
Hydroxyapatite coatings are applied to the surface of metallic implants long (joint prosthesis and dental implants), using technologies such as deposition by CVD, PVD, electrophoresis, electrochemical deposition, sol-gel method, plasma spraying, thermal decomposition. The basic, applied on an industrial scale, a way of coating the surface of HAP implants is plasma technique, used since 1985. Using this technique leads to obtain hydroxyapatite coatings with a thickness ranging from 40÷300 um. Insufficient ownership of utility HAp coatings, prevent their use in high load carrying elements. This paper presents that, the main drawback of the composite implant using HAp, a connection zone coating-substrate. As one of the ways to improve inadequate mechanical properties of HAP bioceramic coatings to modify the proposed addition of zirconia phase. As from analysis of spectrum result FTIR, lack is from structure signs of easing of ions OH of hydroxyapatite, that excludes presence following phase OAp or OHAp. Besides, presence of group make public from phase dating PO4 3-, a-TCP. Modifying the chemical composition of coatings, bioceramic zirconia phase and the addition of an appropriate choice of parameters, obtaining a plasma spray coating method made it possible to achieve high performance in surface protection against corrosion in body fluid environment.
PL
Zainteresowanie biomateriałami, związane z możliwością zastosowania ich na implanty, powoduje z jednej strony nieustanny wzrost wymagań stawiany tego typu materiałom, z drugiej natomiast, poszukiwanie nowych metod i technologii poprawiających ich własności użytkowe. Najczęstsze zmiany składu chemicznego kompozytu ochronnego, tworzonego na powierzchni implantu, polegają na wprowadzeniu do ceramiki hydroksyapatytowej roztworu stałego Y2O3 w ZrO2(YSZ). Priorytetowym celem proponowanych w ramach niniejszej pracy badań była poprawa własności wytrzymałościowych na granicy powłoka-podłoże. Własności te zostały określone przy pomocy testu, polegającego na zarysowaniu (Scratch Test) powłoki ceramicznej.
EN
Growing interest in biomaterials, combined with opportunities of their use for implants causes, on the one hand, incessantly growing expectations imposed on these materials. On the other hand, new methods and technologies of improvement in their functional properties are required. The most frequent changes in chemical composition of the protective composite, created on the surface of an implant include introduction of solid solution of Y2O3 in ZrO2(YSZ) into hydroxyapatite ceramics. A priority goal of the investigations presented within this work was to improve mechanical properties on the base material – coating interface. These properties were determined by means of scratch tests on ceramic coating.
PL
Hydroksyapatyty są grupą materiałów budzącą rosnące zainteresowanie ze względu na ich potencjalne zastosowanie w biotechnologii. Implanty kostne i endoprotezy, których części metaliczne pokrywano warstwą hydroksyapatytu, są w organiźmie ludzkim lepiej tolerowane immunologicznie. W pracy przedstawiono wyniki badań strukturalnych hydroksyapatytów i niektórych związków pokrewnych. Były wśród nich materiały nanokrystaliczne i polikrystaliczne. Powłoki z hydroksyapatytu natryskiwane plazmowo w powietrzu (metodą APS) plazmotronem PN-120 w Świerku wykazują dobrą przyczepność do podłoża metalicznego. Stwierdzono, że struktura badanych powłok jest polikrystaliczna. Badania nad tymi powłokami są jeszcze kontynuowane.
EN
Hydroxyapatites are a group of materials of special interest due to their biocompatibility and applications resulting from this fact for biotechnology. Bone implants and endoprothesis with metallic parts coated hydroxyapatite are better tolerated in the human body and may with overcome immunological barrier. In this work the results of X-ray diffraction studies for hydroxyapatites and some related compounds are presented. Nanocrystalline, partly and fully crystalline forms of these materials have been found. Plasma sprayed hydroxyapatite coatings obtained by the APS method with the use of PN-120 plasmotrone in Świerk show good adhesion to the metallic substrate. On the basis of X-ray diffraction studies polycrystalline structure of the studied coatings is determined. Further studies on these coatings are in progress.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.