EN
The use of hydrogen-rich fuels may be challenging for burner designers due to unique properties of hydrogen compared to conventional fuels such as natural gas. Burner retrofit may be required to use hydrogen-enriched fuels in combustion systems that are designed for natural gas combustion. This study aimed to experimentally investigate NOx emissions from a novel low NOx burner fueled by methane-hydrogen mixtures. The burner was tested in a cylindrical combustion chamber at atmospheric pressure. Burner thermal load of 25 kW (LHV) and air-fuel equivalence ratio of 1.15 were maintained throughout the experimental campaign. The influence of burner design parameters on NOx emissions was tested for various fuel compositions using a statistically cognizant experimental design. The study revealed that shifting the burner head upstream can deliver NOx emission reduction. In contrast, supplying fuel to the burner through secondary fuel ports increases NOx emissions, particularly when the burner head is shifted upstream. The lowest predicted NOx emissions from the burner are below 9 ppmvd at 3% of O2 and 14 ppmvd at 3% of O2 for 5% and 30% mass fraction of hydrogen in the fuel, respectively.
first rewind previous Strona / 1 next fast forward last