Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  hydrofluoric acid
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Ultrafine grained Mg-1Zn-1Mn-0.3Zr alloy and its corrosion behaviour
EN
Purpose: The goal of this paper is to present the corrosion properties of the ultrafine grained Mg-1Zn-1Mn-0.3Zr bulk alloy after surface modification during HF and NaHCO3 treatment. Design/methodology/approach: An ultrafine grained Mg-1Zn-1Mn-0.3Zr bulk alloy was synthesized by consolidating mechanically alloyed powders. The phase and microstructure analysis was carried out using X-ray diffraction, scanning electron microscopy and the properties were measured using corrosion testing equipment. Findings: The sintering of Mg-1Zn-1Mn-0.3Zr powders led to the formation of bulk material with an average grain size of about 73 nm. Ultrafine grained Mg-1Zn-1Mn-0.3Zr alloy was more corrosion resistant than microcrystalline Mg. Practical implications: The results showed an improved corrosion resistance of HF and NaHCO3 treated Mg-1Zn-1Mn-0.3Zr alloy in Ringer solution compared with the untreated sample. The corrosion rate of treated samples followed the order HF
PL
Długotrwały sukces kliniczny stosowania pełnoceramicznych uzupełnień protetycznych, wykonanych z wysokowytrzymałej ceramiki szklanej na bazie dwukrzemianu litu, zależy od możliwości uzyskania trwałego ich połączenia z tkankami zęba za pomocą cementów. Odporność mechaniczną ceramika ta zawdzięcza obecności dużej ilości kryształów dwukrzemianu litu zatopionych w szklistej masie krzemionki oraz ich zwartej strukturze. Metodami standardowo polecanymi do przygotowania powierzchni ceramiki do adhezyjnego łączenia z materiałami kompozytowymi są obróbka strumieniowo- ścierna, trawienie kwasem fluorowodorowym oraz silanizacja. Podaje się, że trawienie ceramiki dwukrzemowo-litowej kwasem fluorowodorowym nie pozwala na uzyskanie zadowalającego wzoru retencyjnego na jej powierzchni. Inni autorzy podają, że struktura krystaliczna tej ceramiki sama w sobie stanowi o jej retencyjności. Dlatego część autorów badań i klinicystów skłania się ku tradycyjnemu cementowaniu uzupełnień wykonanych z tej ceramiki. Jednakże problem ich wewnątrzustnej naprawy za pomocą materiałów kompozytowych pozostaje nadal nierozwiązany. Celem pracy była ocena wytrzymałości połączenia materiału kompozytowego z ceramiką dwukrzemowo-litową w zależności od sposobu przygotowania jej powierzchni. Badaniu poddano próbki ceramiki dwukrzemowo- litowej wykonane metodą tłoczenia, szlifowane na mokro papierami ściernymi o gradacji 600, które poddano obróbce strumieniowo-ściernej zapomocą systemu Rocatec® oraz korundu szlachetnego o grubości ziaren 50 μm lub trawieniu kwasem fluorowodorowym. Po silanizacji powierzchni ceramiki próbki łączono z materiałem kompozytowym za pomocą systemu wiążącego. Wytrzymałość połączenia oceniano w próbie ścinania w urządzeniu do badań wytrzymałościowych Zwick-Roell Z020 przy prędkości przesuwu belki poprzecznej 2 mm/min. Obróbka strumieniowo-ścierna za pomocą systemu Rocatec®, jak również trawienie kwasem HF powierzchni ceramiki pozwoliły uzyskać porównywalną, największą wytrzymałość jej połączenia z materiałem kompozytowym.
EN
Longterm clinical success of using all-ceramic fixed dentures made of high strength lithium disilicate glass ceramic depends on achieving durable bonding with tooth structure by means of cements. High crystal concentration and compact structure of lithium disilicate resolve in high mechanical resistance of this ceramic. Standard procedures of ceramic surface pretreatment include sandblasting, etching with hydrofluoric acid and silanization. It is stated that etching of lithium disilicate ceramic produce poor and insufficient retentive pattern on its surface. Other researchers prove that crystalline structure of this ceramic defines its good retentive features. Therefore some authors as well as dental practitioners tends to bond fixed dentures made of that kind of ceramic by means of traditional cements. However, matter of its intraoral repair still remains unsettled. Aim of this study was to evaluate shear bond strength between feldspathic ceramic and resin composite due to different ceramic surface conditioning methods. Specimens of lithium disilicate press ceramic, polished, were treated with airborne particle abrasion with the Rocatec® system or 50 μm aluminum oxide and/or etched with 9% hydrofluoric acid. After silanization of ceramic surface, specimens were bonded with resin composite by means of bonding system. Shear bond strength was tested in universal testing machine Zwick-Roell Z020 at a crosshead speed 2.0 mm/min. Using Rocatec® system as well as HF acid etching led to achieve almost equal, highest results of shear bond strength of ceramic to resin material.
PL
Z klinicznego punktu widzenia podczas wykonywania wypełnień kompozytowych najistotniejsze jest maksymalne ograniczenie naprężeń skurczowych generowanych na granicy wypełnienie-tkanki zębów, są one bowiem zasadniczą przyczyną powikłań klinicznych. W ostatnich latach dla ograniczenia naprężeń generowanych na granicy wypełnień i twardych tkanek zębów proponuje się wykorzystanie nowo opracowanych materiałów kompozytowych o zmienionym składzie matrycy polimerowej, wskazywanych jako kompozyty o małym skurczu polimeryzacyjnym. O wielkości powstałych naprężeń decyduje jednak nie tylko skurcz polimeryzacyjny, ale także sprężystość materiału kompozytowego. Brak jakichkolwiek badań oceniających naprężenia skurczowe generowane przez te materiały skłonił do podjęcia badań w tym zakresie. W pracy określono wielkości naprężeń skurczowych generowanych podczas polimeryzacji przez różne materiały kompozytowe o małym skurczu polimeryzacyjnym w porównaniu z kompozytami tradycyjnymi. W badaniach elastooptycznych na płytkach z optycznie czułej żywicy epoksydowej przeprowadzono pomiary wielkości naprężeń zredukowanych oraz analizę stanu naprężeń wokół wykonanych wypełnień. Pomiary przeprowadzono za pomocą polaryskopu kołowego FL200/Gunt, wykorzystując do analizy program komputerowy ACD-System oraz metody analizy matematycznej. W badaniach uzyskano różne wartości naprężeń generowanych przez poszczególne materiały kompozytowe. Oceniane materiały kompozytowe różniły się istotnie pod względem naprężeń skurczowych generowanych podczas polimeryzacji. Najmniejsze naprężenia generowały materiały o małym skurczu polimeryzacyjnym, aczkolwiek część materiałów o tradycyjnym składzie fazy polimerowej generowało stosunkowo niskie naprężenia.
EN
From clinical point of view, maximal reduction of shrinkage stresses, generated on the material-hard tissues margin, is the key factor in avoiding clinical complications during cavity restoration with use of dental composites. In recent years, use of new type of low polymerization shrinkage dental composites including modified matrix was suggested to decrease stresses between material and tissues. Quantity of stresses is determined not only by the polymerization shrinkage, but also by flexibility of the composite. Lack of research evaluating shrinkage stresses generated by the materials mentioned has led to the decision on conducting study on this matter. In the research, quantities of shrinkage stresses of various low-shrinkage dental composites in comparison to traditional composites during polymerization were measured. In photo-elastic research with use of plates made of photoelastic sensitive epoxy resin, measurements of reduced stresses quantities and analysis of stresses condition around restorations were made. Measurements were conducted with use of FL200/Gunt circular polariscope, ACD-System software for computer analysis and various methods of mathematical analysis. In research, various values of stresses generated by certain composites were acquired. Evaluated composites varied significantly in shrinkage stresses generated during polymerization. The lowest stresses were observed in composites of low polymerization shrinkage, but some materials of classic composition of matrix also generated low stresses.
PL
Warunkiem połączenia pełnoceramicznych uzupełnień protetycznych, wykonanych z ceramiki krzemionkowej, z materiałem kompozytowym jest rozwinięcie powierzchni ceramiki i jej silanizacja. Metodami standardowo polecanymi do rozwinięcia powierzchni ceramiki są: piaskowanie korundem, trawienie 9,5% kwasem fluorowodorowym (HF) lub połączenie tych metod. Brak jest jednak zgodności, co do oceny skuteczności tych metod przygotowania powierzchni ceramiki do jej połączenia z kompozytem. Celem pracy była ocena wytrzymałości połączenia ceramiki krzemionkowej z materiałem kompozytowym w zależności od sposobu przygotowania jej powierzchni. Badaniu poddano próbki ceramik krzemionkowych wykonanych metodą napalania, które szlifowano na mokro papierami ściernymi o gradacji 600C, piaskowano korundem szlachetnym 50 um i trawiono 9,5% kwasem HF. Po silanizacji powierzchni ceramiki próbki łączono z materiałem kompozytowym za pomocą systemu wiążącego. Wytrzymałość połączenia oceniano w teście ścinania w urządzeniu do badań wytrzymałościowych Zwick-Roell Z005 przy prędkości przesuwu belki poprzecznej 2 mm/min. Stwierdzono istotne różnice w wytrzymałości połączenia materiału kompozytowego z poszczególnymi ceramikami. Powierzchnia próbek ceramiki była również oceniana w mikroskopie elektronowym skaningowym. Uzyskano większe zróżnicowanie powierzchni próbek ceramiki po ich trawieniu kwasem HF w porównaniu z piaskowaniem.
EN
Increasing the ceramic surface area and its silanisation is critical for achieving successful bonding between all-ceramic restorations and composite resin. Standard procedures include sandblasting, etching with 9.5% hydrofluoric acid (HF) or combination of these methods. However, there is an ongoing debate on the best methods of ceramic surface treatment to achieve optimal ceramic-composite bonding. Aim of this study was to evaluate shear bond strength between feldspathic ceramic and resin composite due to different ceramic surface conditioning methods. Specimens of feldspathic build up ceramic, polished, were treated with airborne particle abrasion with 50 ?m aluminum oxide and etched with 9.5% hydrofluoric acid. After silanisation of ceramic surface, specimens were bonded with resin composite by means of bonding system. Shear bond strength was tested in universal testing machine Zwick-Roell Z005 at a crosshead speed 2.0 mm/min. Comparing ceramics significant differences in shear bond strength were observed. SEM analysis of ceramic surfaces was performed. In comparison to airborne particle abrasion, HF etching resulted in greater diversity of morphological surface of ceramics.
EN
The effect of digestion of road dust in the mixture of aqua regia + HF and of the leaching of the analytes with aqua regia only on the determination of Pt and Pd applying ICP-MS technique has been investigated. In order to eliminate spectral interferences in mass spec-trometry. mathematical correction was applied, as well as the interferents were separated from the analytes on a Dowex 50 WX-8 cation-exchange resin. It has been, found that after addition of HF, Hf and Y are transformed into stable fluoride compounds, which are not retained on the cation-exchanger and cause some interferences in the determination step. Leaching of the analytes with aqua regia without complete sample dissolution resulted in the release of Pt and Pd from the road dust. Noteworthy, the analytes were present in the sample in the form suitable for their separation on cation exchanger. The correctness of the applied procedure was confirmed via analysis of certified reference material BCR-723.
PL
Zbadano wpływ sposobu rozkładu próbek pyłu drogowego na oznaczanie Pt i Pd metodą spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS). W celu wyeliminowania interferencji spektralnych zastosowano metodę korekcji matematycznej w spektrometrii mas oraz oddzielanie analitów od pierwiastków inter ferujących (Hf, Y) na kationicie Dowex 50 WX-8. Stwierdzono, że zastosowanie do mineralizacji HF powoduje tworzenie się trwałych połączeń fluorkowych Hf i Y, które nie zatrzymywane na kationicie są przyczyną interferencji w etapie oznaczania. Ługowanie analitów wodą królewską zapewnia ilościowe uwolnienie Pt i Pd z pyłu drogowego, jak również występowanie analitów i pierwiastków interferujących w formie odpowiedniej do ich rozdzielania na kationicie. Poprawność proponowanej procedury potwierdzono analizując certyfikowany materiał referencyjny BCR-723.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.