Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  hydroelectric power
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Wastewater treatment facilities at high places can give chances for renewable and sustainable energy generation by putting hydroelectric turbines at the input and drain channels of wastewater treatment plants, and they can also use the sludge generated during the treatment process to make biogas, which can be used to generate power. Purified water is subsequently used to irrigate decorative plants along highways, in gardens, and in woods. The fermentation wastes are utilized as organic fertilizer to improve agricultural soil quality. At the Gharyan sewage station, a hybrid system consisting of a hydroelectric station and an electric generator powered by biogas is proposed in this research. This is because the city is distinguished by its high location, which is approximately 713 m above sea level. The results showed that the proposed system would provide an electric power of 490 kW, which is sufficient to cover 87.5% of the electrical energy consumption of the station. The amount of treated water is approximately 13,000 m3/day, and the amount of organic fertilizer is about 17 tons/day. The investment value is anticipated to be around $1,478,000, while the cost of producing a unit of electric energy is expected to be 2.83 ¢/kWh. This system's yearly net profit is predicted to be $307,765. The capital's recovery period is anticipated to be 3.44 years. The planned hybrid system will limit the discharge of an estimated 1,886 tons of CO2 gas each year.
PL
W artykule zaprezentowano przykładowe charakterystyki dla wybranej sieci współpracującej z elektrownią wodną. Podstawę służącą do oceny warunków zasilania stanowi Rozporządzenie Ministra Gospodarki z dnia 4 maja 2007r. w sprawie szczegółowych warunków funkcjonowania systemu elektroenergetycznego. Spośród wielu parametrów tej oceny podawanych zarówno przez stosowne Rozporządzenie Ministra Gospodarki jak i zawartych w normie PN-EN 50 160, skupiono się na wyższych harmonicznych. Analizę przeprowadzono w oparciu o rzeczywiste pomiary wykonane rejestratorem jakości energii. Z przeprowadzonych pomiarów został wytypowany reprezentatywny okres będący znormalizowaną podstawą czasową dla prezentowanych przebiegów oraz wyznaczonych wskaźników jakości energii.
EN
The article presents examples of the characteristics of the selected electrical power networks cooperating with hydroelectric power plant. The basis for evaluating the power supply conditions is the Regulation of the Minister of Economy of 4 May 2007, on the detailed conditions for the operation of the power system. Among the many parameters of power quality, the evaluation given by relevant Regulation of the Minister of Economy and parameters included in the PN-EN 50 160, the focus is on the higher harmonics. From the taken measurements it was selected a representative period which is a normalized basis of time for the presented waveforms and set of quality indicators of energy.
3
PL
W 2012 roku zakończona została budowa jazu, mostu i przepławki dla ryb na rzece Głomi w miejscowości Skórka. Nowy jaz umożliwił dalszą eksploatację elektrowni wodnej o mocy 12 kW, a wybudowanie przepławki dla ryb ułatwiło ich migrację. Analiza przepływów wody przez stopień wody wskazuje na konieczność modernizacji elektrowni wodnej. Problemem na stopniu jest również zapewnienie odpowiedniego prądu wabiącego w celu wskazania odpowiedniej drogi dla migrujących ryb. Na podstawie analizy rozwiązań technicznych zaproponowano m.in. wybudowanie drugiej przepławki. W artykule przedstawiono szczegółowo analizę modernizacji stopnia wodnego Skórka z uwzględnieniem wszystkich elementów wchodzących w skład górnego i dolnego stanowiska budowli piętrzącej. Przebudowa obiektów hydrotechnicznych, których stan techniczny wymaga modernizacji powinna uwzględniać charakterystykę pracy wszystkich elementów stopnia aby uniknąć potrzeby poprawy działania elementów już zmodernizowanych. W pracach naprawczych należy przewidzieć różne scenariusze jakie mogą wystąpić w okresie eksploatacji stopnia.
EN
In 2012 the construction of a weir, a bridge and a fish pass on the river Głomia in the Skórka village was com- pleted. The new weir allowed to continue operating hydroelectric power station (12 kW). The construction of fish ladders allowed the migration. The analysis of water flows by the barrage indicates the need for modernization of hydroelectric power. The problem on the barrage is also to provide sufficient current attractant in order to identify a suitable way for migratory fish. The analysis of the technical solutions proposed the construction of a second fish pass. The paper presents a detail analysis of the modernization of the barrage yet, taking into account all the elements constituting the upper and lower positions of the structure. Reconstruction of hydrotechnical objects, technical condition of which requires modernization should take into account the performance characteristics of all elements of the barrage to avoid the need to improve the operation of the elements already modernized. The repair work should be different scenarios that may occur during the lifetime of barrage.
PL
Proces inwestycyjny w hydroenergetyce składa się z pięciu głównych etapów, jakie musi przejść inwestor: koncepcyjnego, administracyjno – prawnego, analizy finansowej, realizacji inwestycji oraz eksploatacji obiektu inwestycji. Celem etapu koncepcyjnego jest sprawdzenie, czy wybrana lokalizacja będzie najlepszą z możliwych pod względem potencjału energetycznego rzeki, sporządzenie oceny oddziaływania na środowisko w celu oszacowania wpływu inwestycji na lokalną faunę i florę, jak również przeprowadzenie konsultacji społecznych. Etap administracyjno – prawny zostaje zakończony, kiedy uzyskane zostaną wszystkie niezbędne pozwolenia: prawo do terenu, decyzja o środowiskowych uwarunkowaniach, pozwolenie wodnoprawne i pozwolenie na budowę. Stworzenie biznesplanu, starania o dotację oraz ubezpieczenie obiektu to składowe etapu analizy finansowej. Realizacja inwestycji kończy się próbnym rozruchem wybudowanej konstrukcji. Ostatni etap, czyli eksploatacja hydroelektrowni jest możliwy po uzyskaniu pozwolenia na użytkowanie oraz uzyskanie koncesji na wytwarzanie energii elektrycznej, co wiąże się z podpisaniem umowy z operatorem na jej sprzedaż. Niezbędne jest również zdobycie świadectw pochodzenia wytworzonej energii.
EN
The investment process in hydroelectric consists of five main steps which investor has to pass: conceptual, administrative - legal, financial analysis, investment realization and life of the investment. The purpose of the concept phase is to verify whether the selected location will be the best possible in terms of the energy potential of the river, preparation of environmental impact assessment to assess the impact of the investment on the local flora and fauna, as well as public consultation. Step administrative - legal terminates when obtained all the necessary permits are: the right to the land, the decision on environmental conditions, the water permit and building permit. Creating a business plan, efforts to grant and insurance components of the building is step financial analysis. The investment ends trial run built structure. The last step, the exploitation of hydroelectric power is possible after obtaining a use permit and obtain concessions for electricity generation, which involves signing a contract with an operator for its sale. It is also necessary to get certificates of origin for generated energy.
PL
Opisano charakter modernizacji napędów zasuw w małych elektrowniach wodnych. Wskazano na praktyczne korzyści wprowadzenia napędów hydraulicznych na konkretnym przykładzie.
EN
The paper describes the nature of the modernization gates driver in small hydroelectric power stations. It has been pointed out the benefit of the application of hydraulic drives with digital control system.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.