Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  human body temperature
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article discusses one of the ways to monitor human health through a continuous comparative analysis of skin temperatures on various parts of the body. Comparing the temperatures of such parts as the armpit, limbs of the arms and legs, it is proposed to draw a conclusion about the state of blood circulation and blood density. A detailed algorithm for processing the measured temperatures is presented. An automated data processing and notification system is proposed. The description of the initial version of the device developed by the authors is given, where the assumptions about possible health problems are notified using light lamps and an audio signal. An inexpensive Arduino NANO microcontroller is proposed as a technical tool for an information processing device.. The research results can be applied in automated systems as hardware and software. The device can be useful in constant monitoring the health status of newborns, people with serious disabilities and people with limited ability to move independently.
2
Content available remote Development Of Test Rig System For Calibration Of Temperature Sensing Fabric
EN
A test rig is described, for the measurement of temperature and resistance parameters of a Temperature Sensing Fabric (TSF) for calibration purpose. The equipment incorporated a temperature-controlled hotplate, two copper plates, eight thermocouples, a temperature data-logger and a four-wire high-resolution resistance measuring multimeter. The copper plates were positioned above and below the TSF and in physical contact with its surfaces, so that a uniform thermal environment might be provided. The temperature of TSF was estimated by the measurement of temperature profiles of the two copper plates. Temperature-resistance graphs were created for all the tests, which were carried out over the range of 20 to 50°C, and they showed that the temperature and resistance values were not only repeatable but also reproducible, with only minor variations. The comparative analysis between the temperature-resistance test data and the temperature-resistance reference profile showed that the error in estimation of temperature of the sensing element was less than ±0.2°C. It was also found that the rig not only provided a stable and homogenous thermal environment but also offered the capability of accurately measuring the temperature and resistance parameters. The Temperature Sensing Fabric is suitable for integration into garments for continuous measurement of human body temperature in clinical and non-clinical settings.
first rewind previous Strona / 1 next fast forward last