Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  high-voltage line
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This article presents the verification of a mathematical model polarimetric current sensor proposed in [1]. The verification was based on computer simulation, which was based on the finite element method. Simulation model was prepared for one of the options for deployment of high voltage cables 110 kV [2]. The simulation was performed for two operating conditions of highvoltage power line - and rated the state short-circuit conditions. In addition, estimated absolute and relative error of measurement.
PL
W artykule przedstawiono weryfikację modelu matematycznego polarymetrycznego czujnika prądu w [1]. W tym celu wykorzystano symulację komputerową, opartą na metodzie elementów skończonych. Opracowany model symulacyjny dotyczył jednej z możliwych opcji rozmieszczenia przewodów na słupie linii elektroenergetycznej wysokiego napięcia 110 kV [2]. Symulacja została przeprowadzona dla dwóch stanów pracy linii wysokiego napięcia - pracy znamionowej i zwarcia. Ponadto został oszacowany błąd bezwzględny i względny pomiaru natężenia prądu za pomocą czujnika polarymetrycznego [1].
PL
W artykule przedstawiono koncepcję realizacji układu kontrolno - zabezpieczeniowego linii elektroenergetycznych wysokiego napięcia 110 kV w oparciu o polarymetryczne czujniki natężenia prądu, w których cewka pomiarowa wykonana jest z jednomodowego światłowodu telekomunikacyjnego różnych standardów oraz Ślizgającą Dyskretną Transformatę Wienera - Chinczyna (SDW-KT). Zaproponowano przykładowe rozwiązania konstrukcyjne - typy włókien światłowodowych, rodzaje źródeł światła oraz rodzaje detektorów światła w polarymetrze. Rozważania teoretyczne poparto wynikami symulacji komputerowej, na podstawie których można szacować odległość centralnego punktu akwizycji i obróbki danych pomiarowych od badanych przewodów fazowych linii elektroenergetycznych wysokiego napięcia 110 kV. Przy użyciu symulacji komputerowej w środowisku MATLAB wykazano, że do analizy sygnałów losowych i niestacjonarnych, którymi są sygnały prądów w przewodach linii elektroenergetycznych wysokiego napięcia, należy stosować SDW-KT. Dodatkowo określono opóźnienie czasowe jaki wprowadza proponowany układ kontrolno - zabezpieczeniowy.
EN
In this paper is presented the concept of implementation the system of protect and control of states of high-voltage power lines 110 kV, based on polarimetric current sensors, in which the measuring coil is made based on various types of telecommunication single mode optical fibers and Sliding Discrete Wiener - Khinchin Transform (SDW-KT). Have been proposed sample design solutions - types of fiber, types of light sources and types of light detectors in the polarimeter. Theoretical considerations supported the results of computer simulations, based on which you can estimate the distance from a central point of acquisition and processing of measurement data to the tested cables of high-voltage power lines of 110 kV. Using computer simulations carried out in an MATLAB software showed that the analysis of those currents in the wires of high-voltage power lines SDW-KT should be used as they are random and non-stationary signals. In addition, specified a time delay with introduces the proposed system of protect and control.
PL
W artykule pokazano, że preferowane jest stosowanie światłowodów telekomunikacyjnych standardów G.652, G.653 i G.655 do wykonania cewki pomiarowej polarymetrycznego czujnika natężenia prądu, zamiast światłowodu wielomodowego. Przedstawiono wyniki symulacji dla cewek o różnej liczbie zwojów i różnych wartości natężenia prądu dla światłowodów jednomodowych i wielomodowych. Zaprezentowano również analizę dokładności pomiaru natężenia prądu za pomocą czujnika polarymetrycznego, w którym cewka pomiarowa wykonana jest ze światłowodu telekomunikacyjnego. W oparciu o symulację komputerową określono, że ułożenie przewodów linii wysokiego napięcia 110 kV nie wpływa na dokładność pomiaru rozpatrywanym czujnikiem natężenia prądu.
EN
This paper describes benefits of using G.652, G.653 and G.655 telecommunication optical fibres for a measurement coil of the polarimetric current sensor. There are given the simulation results for coils of different number of turns and made of various optical fibres - a single-mode and multi-mode fibre. There is presented analysis of the accuracy of current measurement by means of the polarimetric sensor, in which the measurement coil is made of telecommunication optical fibers. Using the classical theory of measurement errors, it is shown that polarimetric current sensors with the measurement coil made of telecommunication optical fiber are characterised by a very high accuracy. Based on computer simulations, it was proved that the 110 kV high voltage cable laying does not affect the presented current sensor accuracy. In the presented polarimetric sensor model it was shown that the distance from the center of the high-voltage power line cable to the optical fiber should be at least 55 mm in order to prevent the impact of macrobendings. This feature will make it possible to use this sensor in remote measurement systems.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.