The effectiveness of lightning protection on the power and distribution grid is a significant factor, which influences the power distribution reliability and the failure rate of system elements. As part of this article, a mathematical model will be presented, taking into account selected parameters that affect the assessment of the lightning hazard of an overhead line. The proposed model will consider the location of the object near the line and the adjustment of line conductor overhangs. Moreover, the mentioned mathematical model allows for analyzing the impact of considered parameters on the protection level of the power system, and transient overvoltages that occur in this system. The article contains also a detailed description of an effective and fast method to assess the lightning discharge impact on the power system with insufficient data. The introduced model was tested to verify the correctness of its operation by comparison of calculation results and functional data. High convergence of calculated and functional data and uncomplicated model structure ensure a wide range of applications for the proposed solution to easily prevent emergency situations in the power system. Furthermore, the described model gives the opportunity to assess the reduction of the range of selectivity zone associated with the power line, in conjunction with the impact of constructional peculiarities and a near object.
PL
Zabezpieczenia różnicowe linii stanowią podstawowe jednostki funkcyjne chroniące odcinki linii w szerokim zakresie aplikacji, także obejmujące transformator w systemie elektroenergetycznym. Wykorzystują przeważnie łącza komunikacyjne jako połączenia światłowodowe punkt – punkt pomiędzy półkompletami lub cyfrowe połączenia multipleksowe do sieci telekomunikacyjnych typu PDH lub SDH, gdzie sygnały przesyłane są po- między węzłami z prędkością o przepustowości podstawowej 64 kBit/s lub jej wielokrotnością. W przypadku braku łączy światłowodowych można zastosować także dostępne kable sterujące dwu- lub czteroprzewodowe typu „pilot wire” lub łącza telefoniczne przez zastosowanie odpowiednich modemów SHDSL. Rozwój infrastruktury telekomunikacyjnej w zakładach energetycznych oraz operatorów sieci przesyłowej umożliwia podpinanie zabezpieczeń odcinkowych także do rozległych sieci WAN (Wide Area Network) typu MPLS (Multiprotocol Label Switching) oraz sieci optycznych CWDM (Corse Wavelength Division Multiplexing), stosując szeroki pakiet kanałów wejściowych pracujących na różnych długościach fali. Istotnym elementem, oprócz warstwy komunikacyjnej, jest właściwe dopasowanie przekładników prądowych do układów zabezpieczeń odcinkowych dla zachowania stabilności pracy podczas zjawiska nasycenia rdzeni przekładników. Zaimplementowany w zabezpieczeniach odcinkowych linii Easergy MiCOM P543-P545 algorytm porównawczo-fazowy wykrywa selektywnie nasycenie przekładników prądowych bez wpływu na czas działania funkcji różnicowej. Zastosowanie algorytmu porównawczo-fazowego umożliwia obniżenie wymagań w odniesieniu do charakterystyk przekładników prądowych stosowanych w układach różnicowych linii.
EN
Line differential protection is the key functional unit protecting line in a wide range of applications in the power system. They usually use communication links as point-to-point fiber optic connections between half-set units or digital multiplex connections to PDH or SDH telecommunication networks, where signals are sent between nodes at a basic speed of 64kBit/s or its multiple. The development of the telecommunications infrastructure in Utilities and the Transmission System Operator enables connecting sectional protection also to WAN networks (Wide Area Networks) type MPLS (Multiprotocol Label Switching) and CWDM (Corse Wavelength Division Multiplexing) optical networks using a wide package input channels operating at different wavelengths. An important element, apart from the communication layer, is the proper matching of the current transformers to the line differential protection systems to maintain operation stability during the surge in the network or the saturation of the transformer cores during close external short-circuits. The additional phase-comparison algorithm implemented in the line differential protections of the Easergy MiCOM P543-P546 selectively detects the saturation of current transformers without affecting the time tripping of the differential function. The use of the phase comparison algorithm allows for lowering the requirements for the characteristics of current transformers used in line differential protection systems.
3
EN
Analysis of ferroresonance phenomena in high voltage (HV) power networks is presented in this paper. The adequate digital simulation model for investigation of ferroresonance oscillations in MATLAB/Simulink program was developed. In the paper HV power system configuration with circuit breaker grading capacitors was described and analyzed. The phase as well as open delta VT voltages and their spectra were considered as signals for ferroresonance detection. Additionally, the possibility of ferroresonance oscillations suppression was also studied.
PL
Wielkoskalowe źródła wytwórcze wymagają przyłączenia do sieci najwyższych napięć. W artykule przedstawiono wybrane wyniki analiz, których głównym celem było określenie zdolności przyłączeniowych stacji krajowej sieci 400 i 220 kV. Analizy wykonano dla modeli systemów odwzorowujących zimowy i letni szczyt obciążenia KSE w horyzoncie do 2015 roku. Dla rozpatrywanego okresu stworzono modele matematyczne KSE uwzględniające planowany rozwój podsystemu wytwórczego, sieci 400 i 220 kV oraz prognozowany wzrost zapotrzebowania. Obliczenia rozpływowe, pozwalające na określenie zdolności przyłączeniowych stacji krajowej sieci najwyższych napięć, zostały wykonane przy wykorzystaniu metody optymalizacji rozpływu mocy OPF, która pozwala na bezpośrednie uwzględnienie ograniczeń sieciowych.
EN
Large-scale power sources require a connection to the high voltage transmission network. The paper presents the results of analysis, whose main aim was to determine the connection abilities of the 400 and 220 kV network stations. Analysis were performed by using the system models reflecting winter and summer peak load conditions in the 2015 horizon. For each year of the examined time period, suitable mathematical models were created taking into account the planned development of the Polish power system including: large-scale power sources, transmission networks and the forecasted growth in peak power demand. Power flow calculations, which were a base for determining the connection abilities of network stations, were made by using optimal power flow method, which allows direct accounting of network constraints.
5
PL
Artykuł przedstawia rozwój technologii przesyłania energii elektrycznej i wykorzystanie nowych, bardziej opłacalnych technologii napowietrznych i kablowych linii elektroenergetycznych. Autorzy opisują kierunki rozwoju techniki stacyjnej wysokich napięć i współczesne tendencje w budownictwie sieciowym. Choć koncentrują się na technologii, to zwracają uwagę na najważniejszy problem w polskich realiach inwestycyjnych, czyli na uzyskiwanie pozwoleń, zezwoleń, decyzji lokalizacyjnych, prawa drogi etc. W obecnych warunkach formalno-prawnych są to przeszkody niemal nie do pokonania, a stan sieci i czasami brak możliwości wyłączeń powodują, że proste zabiegi konserwacyjne zamiast normalnej praktyki eksploatacyjnej stają się prawdziwym wyzwaniem.
EN
The authors explore the development of electric energy transmission solutions and the usage of new cost-effective overhead and cable networks technologies. This reliable and comprehensive report presents the directions of development of HV substations and key tendencies in network construction. Apart from technical aspects, the authors also emphasize the most serious investment problem in Poland, which is the complicated process of obtaining permissions, location decisions, rights of way, etc. the present formal and legal requirements are usually a major hindrance and the network condition and, in some cases, the impossibility of switching off a line, can turn simple maintenance work into a real challenge.