Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  high temperature impact
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
When evaluating concrete, its strength is the most important feature from the practical point of view. In compliance with technological requirements, the strength of concrete depends primarily on its composition, mainly on the content and strength of cement slurry. This is because this concrete component is most susceptible to changes in working conditions in a construction, including high temperature impact on concrete during the fire. The paper presents the results of tests performed on the cement mortar with and without the addition of polypropylene fibers. This treatment allowed for the elimination of the effect of the coarse aggregate by reason of the accuracy of the tested strength characteristics. The studies concerned the impact of high temperature on the change in tensile strength of cement mortars modified with the addition of polypropylene fibers. The analysis of available literature shows that one of the main causes of concrete’s thermal spalling is seen in high tensile stresses. The results of many tests prove that the addition of polypropylene fibers can have a positive effect on the behavior of concrete structures at high temperatures and help reduce spalling. The polypropylene fibers present in a composite may also positively influence the increase in tensile strength. This article discusses the purpose and scope of research, research methods, the experiment plan, test benches, and test results as well. The conclusions of the study were formulated in the final part of the article.
PL
W artykule przedstawiono zagadnienia wpływu wysokich temperatur na kompozyty cementowe: zaczyn, zaprawę i beton. Składy badanych kompozytów nie zawierały żadnych dodatków ani domieszek. Kompozyty badano m.in. na ściskanie, rozciąganie przy zginaniu i przy rozłupywaniu oraz odporność na pękanie, określając ich krytyczny współczynnik intensywności naprężeń KIC. Istotą artykułu są wzajemne relacje odporności na pękanie badanych kompozytów po aplikacji temperatur pożarowych.
EN
This paper presents the results of research on the effects of high temperatures on cement composites, such as: slurry, mortar and concrete. The compositions of the tested elements did not contain any additions or admixtures. Composites were tested based on their bending tensile and compression strength and crack resistance determining their critical stress intensity index (KIC). The purpose of this paper is to show mutual relations of crack resistance between the tested composites in extreme temperatures.
3
Content available remote Ocena szkód pożarowych konstrukcji żelbetowej za pomocą analizy SEM
PL
W artykule przedstawiono zagadnienia związane z oceną szkód pożarowych stropodachu hali produkcyjnej wykonanego z prefabrykowanych elementów żelbetowych. W celu określenia temperatury pożaru wykonano nieniszczące badania wytrzymałości betonu na ściskanie w konstrukcji (metodą sklerometryczną). Badaniom poddano elementy uszkodzone oraz referencyjne (niepoddane oddziaływaniu temperatury) w celach porównawczych. Posługując się wykresami zawartymi w Eurokodzie 2, określono temperaturę, jaką uzyskały elementy w wyniku pożaru. Do oceny szkód pożarowych w żelbetowej konstrukcji nośnej hali wykorzystano również analizę SEM.
EN
The paper consider the issue of the evaluation of fire damages of the flat roof construction of the industry hall build with precast concrete elements. To determine the fire temperature the nondestructive concrete test were made – compressive strength measured with the sclerometer test technique. The test were made for the elements with fire damages and references elements (not affected by temperature). Based on the graphs in Eurocod 2 the temperature of the concrete elements during the fire was determine. To evaluate the fire damages in the construction elements the SEM analysis was conducted.
4
Content available remote Semi-nieniszczące metody oceny betonu w konstrukcji po pożarze
PL
Powszechnie jest stosowanych wiele metod badawczych, służących do oceny betonu in situ. W badaniach wykorzystuje się zależności korelacyjne do określenia wytrzymałości betonu na ściskanie na podstawie mierzonych wielkości fizycznych. W artykule przedstawiono metody semi-nieniszczące: pull-off, pull-out, break-off, destrukcji wewnętrznej oraz penetracji sondą. Omówiono ich przydatność w zastosowaniu do betonu po pożarze, który charakteryzuje się zmiennością cech mechanicznych w zależności od odległości od ogrzewanej powierzchni elementu. Ograniczenia wymienionych metod wynikają m.in. z ustalonej głębokości w przekroju, na której przeprowadzany jest pomiar. Przybliżone zostały także badania nad nowymi metodami, przeznaczonymi do oceny konstrukcji po pożarze. Polegają one na pomiarze oporu wiercenia w betonie.
EN
There are many test methods commonly used to evaluate concrete in situ. Correlative relationships are applied to determine the compressive strength of concrete on the basis of the measured physical quantities. In the paper semi-nondestructive methods are described: pull-off, pull-out, break-off, internal fracture and probe penetration test. Their usefulness in application to concrete after fire is discussed. Concrete then has variable mechanical properties depending on the distance from the heated surface of the element. The limitations of mentioned methods result, among others, from the fixed depth in cross-section where the measurement is made. Research on new methods for the assessment of concrete in structure after fire is also described. These methods are based on the measurement of the drilling resistance in concrete.
5
Content available remote Nieniszczące metody oceny betonu w konstrukcji po pożarze
PL
W artykule omówiono trzy powszechnie stosowane nieniszczące metody badania betonu in situ: sklerometryczną, ultradźwiękową oraz impact-echo. Przeanalizowano ich przydatność do oceny betonu w konstrukcji po pożarze. Zastosowanie wybranej metody nieniszczącej pozwala na wstępne zlokalizowanie obszarów w konstrukcji, w których pogorszeniu uległy właściwości mechaniczne betonu. Badanie bezpośrednią metodą ultradźwiękową lub metodą impact-echo może być użyte do oceny wewnętrznej struktury betonu. Natomiast pośrednia metoda ultradźwiękowa może mieć zastosowanie do szacowania grubości zewnętrznej warstwy betonu, zniszczonej w wyniku oddziaływania wysokiej temperatury.
EN
Three commonly used non-destructive methods of in situ concrete testing: sclerometric, ultrasonic and impact-echo test are discussed. Their suitability for the assessment of concrete in structure after fire is evaluated. Application of selected non-destructive method allows a pre-locate of areas in structure, where concrete has lower mechanical properties. Direct ultrasonic test or impact-echo test may be used to evaluate the internal structure of concrete. An indirect ultrasonic test method may be applied to estimate the thickness of an outer concrete layer damaged by high temperature.
PL
Podgrzanie do wysokiej temperatury powoduje nieodwracalne zmiany mikrostruktury kompozytów cementowych powodujący pogorszenie ich właściwości mechanicznych i trwałości. W pracy zbadano wpływ wysokich temperatur, sięgających do 1000oC, na skład fazowy i mikrostrukturę czterech różnych rodzajów zbrojonych włóknami kompozytów cementowych, przy zastosowaniu rentgenografi i, porozymetrii rtęciowej oraz metody BET. Właściwości resztkowe określono w oparciu o wytrzymałość na zginanie i pozorną dyfuzyjność wilgoci. Wyniki doświadczeń pokazują, że proces zniszczenia matrycy (spiekanie żelu i rozszerzalność kruszywa) wpływa znacznie bardziej na układ porów niż zniszczenie nietrwałych termicznie włókien. Korzystny wpływ na resztkową wytrzymałość na zginanie mają trwałe termicznie włókna, co najmniej do 600oC, jednak względne zmiany wytrzymałości kompozytów z tymi włóknami są większe. Stwierdzono, że pozorna dyfuzyjność wilgoci jest wykładniczo skorelowana z objętością porów kapilarnych.
EN
The high temperature load causes irreversible changes in the microstruclure of cementitious composites resulting in decrease of their mechanical performance and durability. In this paper, the effect of elevated temperatures up to 1000°C on the mineralogical composition and microstructure of four different types of fiber reinforced cement composites is evaluated by means of X-ray diffraction analysis, mercury intrusion porosimetry and nitrogen adsorption porosimetry. The residual properties are characlerized by bending strength and apparent moisture diffusivity. Experimental results show that the degradation processes of matrix (gel sintering and aggregates expansion) influence the pore system more significantly than the degradation of thermally unstable fibers. The residual bending strength is positively affecled by the thermally stable fibers at least up to 600°C but in a relative sense the strength reduction in composites with this type of fibers is more significant. The apparent moisture diffusivity is found to be exponentially correlated by volume of capillary pores.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.