Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  heating power
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available Knitted Heating Mats
EN
The paper deals with conceptual designs and research on flexible knitted heating mats differing in construction from textile heaters on low-elastic woven or nonwoven-foil substrates. Two variants of heating mats with elasticity from 100 to 300 % of relative elongation were designed and manufactured using knitting technology. The heating elements of the mats were parallel-connected sets of electrically conducted carbon threads and synthetic threads coated with silver. With considerable elongation in the range of 210÷270 % no damage was observed to the heating elements and resistance changes during the stretching process equaled from 0.015 to 0.22 Ω/% of elongation. The optimum power of the knitted heater in the range from 16 to 41 W, with high thermal efficiency for a 12 V supply voltage, was obtained thanks to proper density of the electrically conductive threads (resistors) and the appropriate structure of the knitted fabric. The surface temperature of the heater can be adjusted from 34 to 43 °C, which corresponds to human thermal comfort. One of the variants of the knitted heaters was applied in the construction of the seat and backrest of an office chair.
PL
Warunkiem poprawnej pracy pompy ciepła powietrze/woda jest odpowiedni dobór mocy urządzenia do potrzeb grzewczych zasilanych przez nią systemów. Powszechnie zauważalnym problemem jest niedowymiarowanie urządzeń, które skutkuje nadmiernym zużyciem energii elektrycznej pobranej na potrzeby pracy grzałki wspomagającej pracę urządzenia w okresie zimowym. Wbrew pozorom, pompy ciepła przewymiarowane względem potrzeb grzewczych również pracują nieefektywnie. Taki dobór generuje znacząco wyższe koszty inwestycyjne, ale również problemy z odbiorem zbyt dużej w stosunku do potrzeb mocy grzewczej. Nawet w przypadku urządzeń z regulowaną mocą wpływa to negatywnie na ich efektywność energetyczną, zwiększając koszty eksploatacji.
EN
The requirement for the correct operation of an air-to-water heat pump is the appropriate device’s power sizing for the heating needs of the systems it supplies. A well-known problem is the under-dimensioning of the device, which results in increased electricity demand for the operation of the electric heater during the winter. Contrary to appearances, the oversized heat pumps could also work very inefficient. Such condition generates significantly higher investment costs, but also causes the problem with the distribution of excessive heat. Even in the case of heat pumps with the variable-speed compressors, this has a negative impact on their energy efficiency, raising the operating costs.
3
PL
W artykule przedstawiono wyniki pomiarów emisji gazowej (CO, NOx, SO2 i TVOC) z trzech palenisk małej mocy zasilanych różnymi rodzajami paliw: miałem węgla kamiennego lub ekogroszkiem, lekkim olejem opałowym oraz biopaliwem (pelet drzewny). Podano również wyniki oznaczeń zawartości w gazach odlotowych tlenu i dwutlenku węgla oraz rezultaty pomiarów temperatury w miejscach pobrania prób. Stwierdzono istotne różnice w zawartościach oznaczanych substancji w analizowanych gazach. Wykazano, że najniższą emisją CO, NOx, SO2 i TVOC charakteryzował się kocioł ORLINGO 400, w którym spalane były pelety drzewne.
EN
The article presents results of measurements of gas emission (CO, NOx, SO2, and TVOC) for three small forces furnaces fed with various fuel types: fine sized bituminous coal, light furnace oil, and biofuel (wood pellets). The results of analysis of the oxygen and carbon dioxide content in waste gas are also presented, as well as the results of temperature measurements at sites of the samples collection. The significant content differences of analyzed gases are shown. It is revealed that ORLINGO 400 boiler, fueled by wood pellets, had the lowest CO, NOx, SO2, and TVOC gas emission.
PL
Podstawowym zadaniem pomp ciepła jest praca na rzecz systemów grzewczych, jednak dzięki wprowadzeniu niewielkich zmian w konstrukcji urządzenia, może ono mieć również możliwość chłodzenia obiektów w okresie letnim. Takie działanie możliwe jest dzięki zamianie funkcji parownika i skraplacza pompy ciepła. Urządzenie to nazywane jest wówczas rewersyjną pompą ciepła. Ciepło odprowadzane z chłodzonych obiektów czy pomieszczeń, pompa ciepła może oddawać np. do gruntu, dzięki czemu jest on regenerowany (posiada wyższą temperaturę na początku kolejnego sezonu grzewczego). W artykule omówiono zasadę działania rewersyjnej pompy ciepła, zwrócono uwagę na możliwość regeneracji dolnego źródła ciepła w trybie chłodzenia aktywnego, biorąc pod uwagę zarówno koszty inwestycyjne jak i eksploatacyjne będące skutkiem takiego rozwiązania.
EN
The main purpose of heat pumps is application in heating systems. But with slight design modifications a cooling function is also available in summer. If it is possible to change the functions of condenser and evaporator, such a device is called a reversible heat pump. Heat taken from cooled objects or buildings may be given for example to the ground. This way so called heat regeneration of the ground is achieved and at the beginning of the next heating period the ground has higher temperature. In the paper the design and operation of reversible heat pumps are described. Possibilities of ground heat regeneration during active cooling are discussed and involved investment costs and operation costs are taken into account.
EN
The cogeneration systems of energy production are built and developed to achieve the highest economic and ecologic efficiency. These two aims can be realized by increasing energetic efficiency of transforming different sources of energy into technical systems and optimizing usage of own energy. These can be achieved by the usage of different equipment. The search for new constructions, structure and systems is still developing. This article describes the basic principles for use of Stirling engines in micro immobility cogeneration systems. This attempt is made because the Stirling engines seem to be a convenient equipment of optimizing usage of own energy in micro agropower plants. Especially we try to determine which type of the Stirling engine seems to be the best to fulfil the demands in practice. For this purpose a procedure of selection and adjustment of Stirling engines was formulated. In the described procedure many steps ought to be taken for correct choice of all technical arrangements. In this paper the following topics were considered: energetic demands of small houses, maximum instantaneous electric power, consumption of electric energy throughout a year, maximum instantaneous heating power, consumption of heat energy of the year, selection and choice of construction of Stirling engines, selection and choice of pressure of working gas.
6
Content available remote Application of pigfarms radiation heating systems
EN
The folIowing results of the investigation are shown: infrared heater's work with outlet in changing it's heating power and the quantity of exhaust air. The results of investigations can be used for projection of heating systems of pigfarms.
EN
This work presents results of research on the influence of microwave heating time on the process of hardening of water glass molding sands. Essential influence of this drying process on basic properties such as: compression, bending and tensile strength as well as permeability and wear resistance, has been found. It has been proved, that all the investigated sorts of sodium water glass could be used as binding material of molding sands intended for curing with the microwave process heating. It has been found, while analyzing the results of property studies of microwave heated molding sands with 2.5% addition of water glass, that all available on the market kinds of this binding agent (including the most frequently used in foundry 145 and 149 kinds) after microwave heating guarantee very good compression, bending and tensile strength as well as permeability and wear resistance. Moreover, it has been determined that the optimal curing power of molding sands containing various kinds of water glass is 560 W. All values exceeding this result in stabilization of basic properties of molding sands. The use of microwave curing of water glass molding sands results in a significant decrease of hardening a process time, full stabilization of molding sands as well as much lower energy consumption.
PL
W pracy analizowano wydajność grzewczą dolnego i górnego źródła ciepła współpracujących ze sprężarkową pompą ciepła. Określono zmienność wydajności w funkcji różnicy temperatury między zasilaniem a powrotem czynnika obiegowego. Stwierdzono, że w badanych warunkach analizy cyklów pracy pompy ciepła, konieczna jest modyfikacja odbioru energii z górnego źródła.
EN
The paper contains an analysis of heating efficiency for lower and upper heat sources, which work with compressor-type heat pump. The researchers determined efficiency variability in the function of temperature difference between circulating medium supply and return. It was proved that in the examined conditions of heat pump working cycle analysis it is requisite to modify the system for receiving energy from upper source.
PL
W artykule przedstawiono zmianę mocy grzewczej,mocy elektrycznej i współczynnika efektywności energetycznej sprężarkowej pompy ciepła dla dwóch charakterystycznych punktów pracy pompy grzejnej, wynikających m.in. z temperatury dolnego źródła ciepła oraz temperatury zasilania instalacji grzewczej c. o. postronie górnej. Jako dolne źródło ciepła niskotemperaturowego rozpatrzono: powietrze, grunt dla pomp ciepła solanka-woda oraz wodę w przypadku pomp ciepła woda-woda. W pracy zaprezentowano również przykładowe wyniki pomiarów eksploatacyjnych pomp ciepła w domach jednorodzinnych.
EN
The article contains changing of heating power, electrical power and coefficient of performance (COP) for two characteristic points of workingheat pump resulting from a lower source of heat and supply temperature of upper side of central heating system. As a lower source of low-temperature heat there were considered: air, ground for brine to water to water heat pumps.What is more two working heat pumps for one-family houses were shown as example of operating measurements.
PL
W wyniku badań laboratoryjnych przeprowadzonych na modelu palnika inżekcyjnego opracowano założenia dla modernizacji palników, zabudowanych w piecach zapłonowych, która powinna poprawić proces zapalania mieszanki w szczególności w strefach obrzeżnych taśmy spiekalniczej. Uzyskane wyniki badań stwarzają możliwości współpracy z Hutą Katowice lub Hutą Sendzimira nad poprawą równomierności zapalania mieszanki spiekalniczej i obniżenia strat na taśmie przez obniżenie ilości spieku zwrotnego.
EN
As a result of laboratory tests carried out on the injection burner model, principles for modernisation of burners installed in ignition furnaces were developed. This modernisation should improve the mix ignition process, in particular within the peripheral areas of the sinter belt. The test results obtained in this way provide a chance to cooperate with the Huta Katowice or the Huta Sendzi-mira on improvement in the uniformity of sinter mix ignition and reduction in losses on the belt by reducing the amount of return sinter.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.