EN
Solar control devices have a significant effect on providing indoor thermal comfort by minimizing annual energy costs in hot-dry climates. Within the scope of the study, the settlement pattern Şilbe 1st Stage Mass Housing settlement located in the city of Diyarbakır, which is located in the hot dry climate zone, was discussed. Horizontal-vertical solar control devices were placed on the transparent surfaces in east-west and northeast-southwest directions, which give optimum results due to the shadow effect, by means of the DesignBuilder Simulation Programme, and the effect of annual heating and cooling energy load expenses was examined.This study aimed to examine the effect of solar control devices on energy saving in hot dry climate regions.As a result of the study, solar control devices placed in both east and west directions provided a significant decrease in annual energy costs. In addition, the types of solar control devices (horizontal or vertical) used had an impact on annual energy costs. As a result of the analysis, it was determined that horizontal solar control devices should be preferred in hot-dry climate regions. This study will be a guide for the studies carried out within the scope of energy efficient structure design of solar control devices.
PL
Wycofana norma PN-EN ISO 13790 została zastąpiona normą PN-EN ISO 52016, która określa wiele metod obliczeniowych zapotrzebowania na energię budynków do ich ogrzewania, chłodzenia, nawilżania i odwilżania powietrza wewnętrznego, obliczania bilansu energii i wyznaczania temperatury wewnętrznej w budynkach oraz wyznaczania zapotrzebowania na moc ogrzewania i chłodzenia. W artykule opisano metody obliczeniowe zawarte w tej normie oraz omówiono związki pomiędzy tą normą i normą PN-EN ISO 52017 oraz innymi powołanymi normami. W artykule przedstawiono również różnice metod obliczeniowych wycofanej normy PN-EN ISO 13790 i normy omawianej w artykule.
EN
The with drawn PN-EN ISO 13790 standard has been replaced by the PN-EN ISO 52016 standard, which contains a number of calculation methods for energy demand of buildings for heating, cooling, humidifying and dehumidifying indoor air, calculating the energy balance and determining the indoor temperature in buildings and determining the heating and cooling loads. The article describes the calculation methods contained in this standard and discusses the relationship between this standard and the PN-EN ISO 52017 standard and other referenced standards. The article also presents the differences in the calculation methods of the withdrawn PN-EN ISO 13790 standard and the standard discussed in this work.
3
Content available remote Termomodernizacja kaplicy klasztornej - studium przypadku
PL
W Polsce jest stosunkowo niewiele budowli o charakterze zabytkowym, które są w dobrym stanie technicznym. Większość z nich wymaga częściowej lub całkowitej termomodernizacji, którą należy przeprowadzić tak, by w możliwie największym stopniu zachować ich historyczne walory. Stąd wynikają różnorakie ograniczenia dotyczące doboru materiałów i technologii wykonania, które ze względu na swoją specyfikę są zawsze droższe niż w innych obiektach. W artykule, na przykładzie domu klasztornego Sióstr Bernardynek w Św. Katarzynie k/Kielc, omówiono równoważenie kosztów inwestycyjnych oszczędnościami na ogrzewanie przy różnych parametrach kredytowania. Na podstawie cen roku 2018 obliczono optymalną grubość izolacji przegród ciepłochronnym tynkiem na bazie perlitu ułożonym od wewnątrz. Przy trzyletnim okresie kredytowania i stałej stopie procentowej 8% optymalna grubość izolacji wynosi 3,6 cm przy całkowitym koszcie termomodernizacji ściany kaplicy równym 112,53 zł/m2, a wykonanie dwóch warstw o całkowitej grubości 6 cm zwiększa koszty tylko do około 120 zł/m2, co powoduje ponad 25% obniżenie strat ciepła przez przenikanie. Wskazano również, że wraz z wydłużeniem okresu kredytowania inwestycji, korzystnie rośnie wielkość optymalnej grubości izolacji. Natomiast wpływ wielkości stopy oprocentowania jest stosunkowo niewielki. Na przykładzie kaplicy klasztornej omówiono również efekty rozłożenia procesu termomodernizacji na etapy.
EN
There are relatively few historic buildings in Poland that would be in good technical condition. Most of them require partial or complete thermal modernization, which should be carried out so as to preserve their historical values as much as possible. Hence, there are various restrictions on the choice of materials and production technology, which are always more expensive due to their specificity. Here, on the example of the monastery house of the Bernardine Sisters of St. Katarzyna near Kielce, the benefits of balancing the costs and benefits of investments based on cost accounting were shown. Based on the prices of 2018, the optimal insulation thickness was calculated for heat-insulated perlite plaster from the inside. With a three-year loan period and a constant interest rate of 8%, the optimal insulation thickness is 3.6 cm with a total cost of thermo- modernization of the chapel wall equal to 112.53 PLN/m2, and the implementation of two layers with a total thickness of 6 cm increases costs to only about 120 PLN/m2, however, this results in a more than 25% reduction of heat transfer through the partition. It was also pointed out that as the investment loan period was extended, the optimum insulation thickness increases favorably. However, the impact of the interest rate is relatively small. The effects of spreading the thermomodernization process on stages were discussed on the example of the monastery chapel.
PL
W pracy przedstawiono wyniki badań i analiz zużycia energii w wolnostojącej szklarni z ekranem termoizolacyjnym. Celem tych badań była analiza zmienności obciążenia cieplnego w szklarni z ruchomym ekranem termoizolacyjnym. Analizy wykonano w oparciu o pomiary parametrów klimatu, mikroklimatu szklarni, zużycia energii oraz parametrów opisujących funkcjonowanie wyposażenia technicznego szklarni. Według analiz średni miesięczny współczynnik obciążenia zawiera się w zakresie od 9% do 69%. Przedstawiono miesięczną i dobową strukturę zużycia energii w badanej szklarni z ekranem i bez ekranu. W analizach zmienności obciążenia cieplnego systemu grzewczego szklarni z ekranem termoizolacyjnym zaleca się korzystać z danych zużycia energii lub zapotrzebowania na ciepło.
EN
This paper presents results of investigation of the free-standing greenhouse with movable thermal screen inside. Energy consumption by the modern greenhouse object is analyzed, basing on the in-situ measurements. The aim of these investigation was analysis variability of heating load in greenhouse with thermal screen. The analysis was based on the registration of the external climate parameters, greenhouse microclimate, energy consumption and parameters describing the functioning of the technical equipment of greenhouse. The computations show that the mean monthly Load Factor is in the range from 9% in June to 69% in January. Shows the structure of energy consumption per month with regard to the functioning of the greenhouse with and without a thermal screen as well as its profile changes in cross daily. In analyzes of variability heating load in greenhouse with additional cover it is recommended to use the data about energy consumption or heat demand.
PL
W pracy przedstawiono wyniki obliczeń metodą elementów skończonych zmiany temperatury ścian pieca podczas nagrzewania, wygrzewania i chłodzenia w piecu komorowym. Przeprowadzono analizę wpływu konstrukcji obmurza pieca na ilość ciepła akumulowanego oraz oddawanego do otoczenia. Oceniono ilość energii akumulowanej przez wsad. Oszacowano zmianę wartości współczynnika wymiany ciepła w piecu dla zmiennego cyklu technologicznego. Określono typ konstrukcji, pozwalający osiągnąć najniższe wartości całkowitego ciepła zużytego na utrzymanie właściwej temperatury ściany w procesie nagrzewania. Obliczenia przeprowadzono dla stałego i zmiennego kroku czasowego.
EN
Charge heating for metal forming processes in the chamber furnaces is an energy consuming operation. Heat consumption results not only from charge temperature increase to the desired temperature at a level of 1200˚C and heat loses to the environment. Essential heat expenditure are required for elevating the furnace structure temperature to the operating temperature. Heat accumulated in the furnace walls depends on the heat capacity and mass of the insulating materials. Numerical simulations of the heat losses to the environment and heat accumulated in the furnace walls have been analyzed for various combinational of the insulating materials. The optimal furnace wall insulation has been proposed. Numerical issues concerning accuracy of the solution and the computation time has been addressed as well.
PL
W pracy przedstawiono model numeryczny wymiany ciepła w piecu grzewczym. Zaprezentowano wyniki symulacji komputerowych ukazujących wpływ wyłożenia ogniotrwałego pieca na proces nagrzewania wsadu. Analizie poddano pole temperatury i jego jednorodności we wsadzie, oraz czas potrzebny do nagrzewania wsadu. Model numeryczny i obliczenia opracowano w pakiecie ANSYS Fluent 14.5. Walidacji modelu numerycznego dokonano przy użyciu pieca testowego znajdującego się na wyposażeniu Katedry Techniki Cieplnej i Ochrony Środowiska AGH w Krakowie.
EN
This paper presents a numerical model of heat transfer in a heating furnace. The results of computer simulations show the influence of the refractory lining on the furnace charge heating process. The temperature field, the uniformity in the charge and the time needed to heat the charge have been analyzed. The numerical model was developed and calculations have been developed using the commercial program ANSYS FLUENT 14.5. Validation of the numerical model was made using a furnace testing equipment located on the Department of Thermal Engineering and Environment Protection, AGH University in Krakow.
PL
W pracy przedstawiono model numeryczny oraz wyniki obliczeń nagrzewania wsadu w przemysłowym piecu komorowym opalanym gazem ziemnym. Pola temperatur wsadu i elementów konstrukcji pieca zostały wyznaczone pakietem numerycznym ANSYS - Fluent 14.5. Wyniki obliczeń zostały porównane z pomiarami przeprowadzonymi w trakcie nagrzewania wsadu w piecu komorowym przeznaczonym dla wsadu wielkogabarytowego do przeróbki plastycznej. Analizie poddano jednorodność pola temperatury wsadu oraz gradient temperatury w elementach konstrukcji pieca. Opracowany model pozwala na optymalizację procesu nagrzewania wsadu w piecu komorowym.
EN
Charge heating in the industrial furnaces is a difficult and complex process. There are many physical phenomena which influence heat transfer. At the charge surface heat transfer takes place by radiation and convection. In order to ensure correct operation of the technological system, it is necessary to achieve the required charge temperature in the whole volume and ensure its uniformity. This paper presents the numerical model and the results of calculations of charge heating in the industrial chamber furnace. The temperature field of materials and structural elements of the furnace have been performed using the commercial program ANSYS - FLUENT. The calculation results has been compared with results of hating in industrial furnace. The homogeneity of the charge temperature field has been analysed. Developed model allows to optimize the heating process in the furnace chamber.
PL
Obliczenia cieplne budynku dotyczą zagadnień przepływu ciepła w jego strukturze i przestrzeni. W ostatnich latach ich zakres uległ rozszerzeniu o obliczenia zapotrzebowania na energię zużywaną w budynku w związku z wdrożeniem w Polsce wymagań wynikających z dyrektywy 2002/91/WE w sprawie charakterystyki energetycznej budynków. Przeprowadzono analizę możliwości harmonizacji procedur obliczeniowych stosowanych w obliczeniach zapotrzebowania na energię i obciążenia cieplnego budynków w celu uproszczenia i weryfikacji tych obliczeń.
EN
Thermal calculations for buildings are related to problems of heat transfer in the space and structure of a building. Recently, the scope of these calculations has been extended to calculate energy demand of a building according to implementation of the requirements given in the EPBD Directive to the Polish building regulations. The possibilities of harmonization procedures applied in calculations of energy demand for a building and its heating load in the aim to simplify and verify these calculations were analysed.