This paper presents the results of research into high-pressure recuperation heaters used in BC-50 heating blocks of a chosen heat and power generating plant. During the operational process of heat exchangers in some characteristic locations of heat equipment, intensive repetitive degradation of heat exchange surfaces takes place that requires looking into its origins. This degradation led to the perforation of walls of tube packets in extreme cases. The aim of the research was to identify the causes of the damage in order to eliminate them. The research relied on the measured operational parameters of the studied heat exchangers recorded in a passive experiment by a recording control system of a heating block.
PL
W artykule przedstawiono wyniki badań wysokoprężnych wymienników regeneracyjnych stosowanych w blokach ciepłowniczych BC-50 wybranej elektrociepłowni. W procesie eksploatacji wymienników ciepła występuje w charakterystycznych lokalizacjach aparatów cieplnych powtarzająca się, wymagająca rozpoznania genezy, intensywna degradacja stanu ich powierzchni wymiany ciepła. Degradacja ta w skrajnych przypadkach doprowadzała do perforacji ścianek pakietów rurowych. Przeprowadzone badania miały na celu zidentyfikowanie przyczyn powstawania tego typu uszkodzeń w celu ich wyeliminowania. W badaniach wykorzystano wyniki pomiarów parametrów pracy badanych wymienników ciepła zarejestrowane w eksperymencie biernym przez układ pomiarowo-rejestrujący bloku ciepłowniczego.
PL
Do głównych urządzeń wchodzących w skład typowego bloku ciepłowniczego BC–50 elektrociepłowni należą między innymi podgrzewacze regeneracyjne wysokoprężne. Przeznaczone są do podgrzewania wody zasilającej kocioł parowy w części wysokoprężnej bloku ciepłowniczego. Czynnikiem grzewczym jest para przegrzana pochodząca z nieregulowanych upustów pary w części wysokoprężnej turbiny parowej. Podczas wymiany ciepła zachodzącej w podgrzewaczach bardzo istotną rolę stanowi ciepło skraplania pary. Przedstawione w artykule badania dotyczą oceny efektywności energetycznej pracy przedmiotowych podgrzewaczy. Badania przeprowadzono w aspekcie wykorzystania ciepła skraplania pary podczas wymiany ciepła zachodzącej w podgrzewaczach oraz możliwości zoptymalizowania ich pracy. Do badań wykorzystano wyniki pomiarów zarejestrowanych przez system pomiarowo–rejestrujący, wybranego bloku ciepłowniczego elektrociepłowni. LITERATURA
EN
The main devices in the heating block of a typical heat and power station are among other high-pressure regenerative heaters. They are designed to heat the steam boiler feed water in the high-pressure part of heating block. Heating medium is superheated steam coming from non-regulated vents of high-pressure part of steam turbine. Heat of condensation is a very important during the heat exchange occurring in heater. Studies presented in this article concerns the evaluation of the energy efficiency of the work in research heaters. The study was conducted in the context of the use of heat of condensation during heat transfer occurs in heater and the ability to optimize their work. The study uses the results of the measurements recorded by measuring and recording system, the selected heating block of heat and power station.
PL
Przedstawiono wyniki analizy energetycznej i ekonomicznej krajowych technologii dużej kogeneracji. Wykonano przegląd sprawności egzergetycznej wytwarzania ciepła w węglowych blokach ciepłowniczych z turbinami przeć i w prężnymi i upustowo-kondensacyjnymi, uciepłownionej elektrowni węglowej oraz bloku ciepłowniczym gazowo-parowym. Wykonano również analizę wskaźnika PES (Primary Energy Saving) w tych technologiach. Zwrócono uwagę na możliwość poprawy efektywności ekonomicznej elektrociepłowni przez zastosowanie zasobników ciepła.
EN
Presents the results of energy and economic analysis of the national high cogeneration technology. A review is presented concerning the efficiency of heat exergy production of coal-fired district heating blocks with the back pressure and extraction-condensing turbines, coal-fired power station adapted for the production of heat feeding and gas/steam generation unit. An analysis has also been carried out concerning the PES (Primary Energy Saving) indicator used in these technologies. Attention is drawn to the possibility of improving the economic efficiency of power plants by applying heat reservoirs.
PL
W pracy omówiono problem identyfikacji zależności mocy elektrycznej od cieplnej bloku energetycznego. Charakterystyka ta pomaga przy rozważaniach zmiany krzywej grzewczej miasta i oraz w zaplanowaniu harmonogramu pracy upustów. Ponadto może być wykorzystana do określania maksymalnej mocy elektrycznej przy danej temperaturze powietrza zewnętrznego, zakładając, że zostanie pokryte zapotrzebowanie odbiorców. Podano wyniki pomiarów dla bloków ciepłowniczych Elektrowni Bełchatów.
EN
The article discusses an issue of electric and thermal relation identification in a power unit. This specification is very useful as regards analysis of alterations of a heating curve of the city and fixing schedule of tapping points operation. Moreover it may be also used in order to specify maximum electric power at a given temperature of external air, making an assumption that demand of recipients will be covered. There are showed measurements results of heating blocks in a Power Station of Belchatów.