Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  heat wave
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available Heat waves and health impact on human in Baghdad
EN
This investigation aim to evaluate the effect of heat wave on health of human, so to achieve this 40 blood samples for person exposed to heat wave were drawn most patients were attend to specialists in hospital laboratories (Medical City, Ibn al-Baladi, Sheikh Zayed, Kadhimiya Educational). The patients aged 10–60 years, male (20) and female (20). CBC analyzes was performed. The result of the presents study recorded a highly signifi cant difference in total (mean and percent) as compared with the normal value of the CBC analyze the result for total (mean and percent) for male the factors CRP, ESR, WBC, PCV, PL (15.5, 43, 11.35, 28.5, 215) respectively (100%, 100%, 100%, 100%, 100%) and the result for total (mean and percent) for female the factors CRP, ESR, WBC, PCV, PL (15, 43.5, 11.35, 31, 220.5) respectively (100%, 100%, 100%, 100%, 100%). According to the result we can conclude that there was a highly significant deferent in mean value for patient compared with the normal value which is the mean cause of hard attack which lead to death. The study is the first of its kind in the Department of Atmospheric Sciences in Iraq.
EN
Heat waves are defined as at least 3 consecutive days with maximum temperaturę >30°C (Krzyżewska, Wereski 2011). Their course largely depends on the circulation conditions, but local conditions related to the geographic location and surroundings of the station also play an important role. According to the International Panel for Climate Change, heat waves are treated as extreme events (IPCC 2014) that will be longer and more intensive in the future (Meehl, Tebaldi 2004). One of the longest and most intensive heat waves in Central-East Europe occurred in the first half of August 2015. In the Lublin Region, it commenced on 3 August 2015, and lasted continuously for almost two weeks. The objective of the paper is to present the variability of the thermal conditions that occurred in the Lublin Region during an exceptionally strong heat wave in August 2015. The analysis was performed based on data obtained from six stations of the Institute of Meteorology and Water Management (IMGW) and seven automatic field stations of the Maria Curie-Skłodowska University (UMCS).
EN
Heat waves were analysed on the basis of maximum daily temperature from 24 meteorological stations in Poland. Heat waves are defined as the longest continuous period during which Tmax (daily maximum air temperature) is equal to or higher than 30°C in at least three days, the mean Tmax during the whole heat wave is equal or higher than 30°C and Tmax does not drop below 25°C during the whole period of heat wave duration. Heat waves occur in Poland from April to September with their maximums in July and August. Four-day-long heat waves are most frequent but the longest one lasted 31 days. The most persistent heat waves were in 1994 and 2015. An increasing trend in heat wave frequency and intensity is observed in Poland, however the increase is statistically significant at only about 60% of analysed stations. Four synoptic patterns favouring heat waves have been distinguished. A strong high over the Azores accompanies all of them, as well as slightly higher than normal pressure over Central Europe – this causes calm and sunny weather over Poland. Strong blocking appears over the North Atlantic during heat wave events, proofing that the development of strong heat waves in Poland is related to large scale circulation and that they are not of local origin. The analysis of the impact of soil moisture in months leading up to the development of heat waves should be the next step in analysis.
EN
ABSTRACT Objective: Currently, the pulse-type dry chemical extinguishing system (DCES) is extensively used for extinguishing fires. These units generally consist of a control junction and powder extinguishing modules (PEM) filled with fire extinguishing powder and gas pumped into the module under the high pressure. Giving extinguishing powder from the PEM in the fire source is carried out when exposed to the heated air of the thermal column generating lift. The magnitude of this force depends on the power of fire and intensity of air change in the room. The efficiency of fire extinguishing with the DCES in these conditions will be determined not only by the powder extinguishing ability but also its dynamic characteristics when approaching the fire. In the design of pulse-type fire extinguishing systems using PEMs it should be considered that during testing PEMs the dynamics of the gas powder mixture released from the module is impacted by the air resistance and the lift of the heated gases from the thermal column from the fire source. Aim: The aim of this work is to determine the ratio of the unit weight of dry chemical extinguishing powder depending on the distance from the nozzle of the DCES for the defined pneumatic and loading characteristics of the system, disperse parameters of dry chemical powder and the fire power. Project and methods: To reach the aim of the study, a mathematical model approach was applied for the flow process the extinguishing substance from the DCES and its movement in open-air space towards the fire. Results: A mathematical model was developed to calculate the movement dynamics of the gas-powder mixture in an open-air space towards the fire source under specific performance parameters of the DCES and the power of the fire. A correlation for estimating the extinguishing powder particle velocity at different distances from the DCES nozzle during their movement towards the fire of a given power was obtained. An experimental study of the dynamics of the front of the powder mixture ejected from the pulse-type PEM was performed. The analysis of the results showed their satisfactory level of compliance with numerical calculations. Conclusions: The obtained results can be used for analyses of pulse-type PEMs with a goal of assessing the spatial and energy parameters of fires which can be extinguished using this method. The results can be used during the design of such installations in order to specify the pneumatic and load parameters of the module associated with the given technical characteristics of the extinguishing agent, the assumed power level of the fire source and the height of the PEM.
PL
Wprowadzenie: W obecnych czasach modułowe proszkowe instalacje gaśnicze typu impulsowego są powszechnie wykorzystywane do gaszenia pożarów. Instalacje te składają się zazwyczaj z modułów sterowania oraz modułów gaszenia proszkowego, które wypełnione są proszkiem gaśniczym i gazem pod wysokim ciśnieniem. Na proszek gaśniczy podawany z modułów gaszenia proszkowego do ogniska pożaru oddziałuje nagrzane powietrze komina termicznego, generujące siłę nośną. Wielkość tej siły zależy od mocy pożaru i intensywności wentylacji pomieszczenia. W takich warunkach efektywność gaszenia pożaru za pomocą instalacji proszkowej będzie zależna nie tylko od skuteczności gaśniczej proszku, lecz także od jego charakterystyk dynamicznych, podczas gdy przemieszcza się w stronę źródła pożaru. Przy projektowaniu modułowych proszkowych instalacji gaśniczych typu impulsowego, a także podczas badań modułów gaszenia proszkowego należy uwzględniać, że na dynamikę ruchu mieszaniny gazowo-proszkowej wyzwalanej z modułu wpływają oporność powietrza oraz siła nośna rozgrzanych gazów komina termicznego ze źródła pożaru. Cel: Celem pracy jest wyznaczenie zależności między prędkością jednostkowej masy proszku gaśniczego a lokalizacją otworu wylotowego modułu gaszenia proszkowego typu impulsowego w warunkach określonych charakterystyk pneumatycznych i obciążeniowych modułu, parametrów dyspersji proszku i mocy pożaru. Projekt i metody: Aby zrealizować wyznaczony cel, zastosowano metodę modelowania matematycznego ubytku środka gaśniczego po jego wyzwoleniu oraz jego ruchu w kierunku źródła pożaru w przestrzeni otwartej. Wyniki: Opracowano model matematyczny dynamiki ruchu mieszaniny gazowo-proszkowej, odbywającego się na przestrzeni otwartej w kierunku źródła pożaru oraz w określonych warunkach parametrów pracy modułów gaszenia proszkowego oraz energii pożaru. Otrzymano zależność do oceny prędkości cząsteczek proszku gaśniczego w różnych odległościach od otworu wylotowego modułu gaszenia proszkowego, podawanego w stronę pożaru o określonej mocy. Przeprowadzono badania eksperymentalne dynamiki przemieszczania się frontu gazowo-proszkowej mieszaniny wyrzucanej przez moduły gaszenia proszkowego typu impulsowego. Analiza otrzymanych wyników świadczy o zadowalającej zgodności z obliczeniami numerycznymi. Wnioski: Otrzymane wyniki mogą być wykorzystane przy przeprowadzaniu badań modułów gaszenia proszkowego typu impulsowego mających na celu ocenę parametrów przestrzennych i energetycznych pożarów, które mogą być nimi ugaszone. Rezultaty można wykorzystać również podczas projektowania tego rodzaju instalacji w celu określenia parametrów pneumatycznych i obciążeniowych modułu związanych ze znanymi technicznymi charakterystykami środka gaśniczego, zakładanych wartości mocy źródła pożaru i wysokości umieszczenia modułu gaszenia proszkowego.
5
Content available remote Changes in thermal extremes in Poland
EN
Changes in thermal extremes of the climate of Poland in 1951-2010 are examined. Warm extremes have become more frequent, while cold extremes have become less frequent. In the warming climate of Poland, the increase in the number of extremely warm days in a year and the decrease in the number of extremely cold days in a year have been observed. Also the increase of the maximum number of consecutive hot days in a year and the decrease of the maximum number of consecutive very cold and extremely cold days in a year have been observed. However, the trends are not of ubiquitous statistic significance, as the natural variability is strong.
6
Content available remote Monitoring the course of hydration heat development of gypsum
CS
V článku je studován vliv plastifikačních a hydrofobizačních přísad a vodního součinitele na průběh hydratace energosádry ve srovnání s průběhem naměřeným na referenční energosádře bez přísad. Měření provedená pomocí kalorimetru KC 01 ukazují výskyt β-anhydritu III v sádře, který poněkud zvyšuje naměřená hydratační tepla ve srovnání s tabulkovými hodnotami. Vliv přísad se projevuje pouze v určitém zpomalení hydratační reakce, ale neovlivňuje celkové hydratační teplo. Vliv teploty na průběh hydratace energosádry v rozmezí 1-40°C se ukazuje jako významný a projevuje se přibližně lineární závislostí maxima výkonu na teplotě.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.