Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 29

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  heat load
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Roller blinds are devices that are retracted and wrapped in a box above the window opening and are used to protect against the solar radiation. Those are the well-known devices with distinct advantages over the fixed external dimming elements. The influence of external blinds on the internal thermal environment in climatic conditions in the Republic of Serbia, the city of Kragujevac, was considered in this research. An external blind was installed in the test room and its influence on the internal temperature was compared with the internal temperature of the room without the blind. Real-time monitoring was carried out in February and August 2023. The results presented in this paper show that the blind reduces the temperature in summer by 3.57ºC and increases it in winter by 1.76ºC. The cooling load can be reduced by about 20%, and the heat load by about 15%.
EN
The paper presents the assumptions and methodology for investigating equivalent heat load testing of hot aircraft engine components. The basic heat loads occurring in an aircraft engine during aircraft flight are characterised. Diagrams of the proposed heat loads are presented, together with the number of cycles, and a test bench is characterised and shown to enable equivalent heat load testing of aircraft engine components.
PL
Ocena wydajności systemu ogrzewania stropowego w budynku wymaga uwzględnienia temperatury zewnętrznej obliczeniowej i średniorocznej w pomieszczeniach oraz współczynników przenikania ciepła przegród. Przeanalizowano właściwości grzejne stropu DX-Therm na przykładzie budynku mieszkalnego zlokalizowanego w trzech sąsiadujących krajach europejskich. Rozwiązanie okazuje się energooszczędne i komfortowe we wszystkich mieszkaniach w Polsce i Niemczech. Poddano dyskusji możliwość dostosowania go do warunków ukraińskich. Scharakteryzowano cechy termoaktywnego stropu prefabrykowanego.
EN
The assessment of the performance of a ceiling heating system in a building requires the consideration of room, external design and average annual temperature values and building envelope heat transfer coefficients. The DX-Therm ceiling heating properties have been analysed for three neighbouring European countries using an apartment building as an example. The solution proves to be energy efficient and comfortable in all apartments in Poland and Germany. The possibility of adapting it to the Ukrainian conditions is discussed. The features of the thermoactive prefabricated ceiling are characterised.
4
Content available remote Wpływ bezwładności cieplnej budynku na wykres obciążeń
PL
Specyficzną cechą systemów ciepłowniczych jest fakt, że obciążenie cieplne systemu charakteryzuje się dużą zmiennością w ciągu roku. Do analizy tej zmienności mającej wielorakie zastosowanie wykorzystywany jest wykres obciążeń cieplnych. Podstawą sporządzania wykresu obciążeń jest zmienność temperatury powietrza zewnętrznego charakterystyczna dla lokalizacji obiektu, dla którego sporządzany jest wykres. W metodologii sporządzania wykresu zakłada się w każdej chwili proporcjonalność strat ciepła na ogrzewanie i wentylację do różnicy temperatury powietrza wewnętrznego i powietrza zewnętrznego, pomijając bezwładność cieplną przegród budowlanych. W przedstawionym artykule przeprowadzono analizę wpływu bezwładności cieplnej przegród na zmienność obciążeń cieplnych w roku, porównując ją z dotychczas stosowanym wykresem obciążeń. Do wyznaczenia bezwładności cieplnej wykorzystano opracowaną wcześniej metodologię obliczeń. W efekcie wykazano znaczną różnicę pomiędzy teoretycznym i rzeczywistym przebiegiem wykresu obciążeń cieplnych. Wyniki potwierdzono przykładami zmian zużycia ciepła w rzeczywistych obiektach budowlanych.
EN
A specific feature of district heating systems is the fact that the heat load of the system is highly variable through the year. The heat load diagram is used to analyze this variability with multiple applications. The basis for the preparation of the load diagram is the variability of the outside air temperature, characteristic for the location of the object for which the diagram is prepared. The methodology of drawing up the diagram assumes that the heat loss for heating and ventilation is proportional to the temperature difference between internal and external air at any time, ignoring the thermal inertia of building partitions. In the presented article, an analysis of the influence of thermal inertia of partitions on the thermal loads’ variability during a year was carried out, in comparison with the load diagram used so far. The calculation methodology developed earlier was used to determine the thermal inertia. As a result, a significant difference was demonstrated between the theoretical and real course of the thermal load diagram. The results were confirmed by examples of changes in heat consumption in real buildings.
5
Content available remote Influence of changing climatic conditions on heat pump efficiency
EN
The analysis of energetic and economic efficiency of application of heat supply systems on the basis of brine heat pumps of different types for a covering of heating loading is carried out. The influence of bivalent temperature on the power choice of the heat pump system is shown.
6
Content available remote Weryfikacja zamówionej mocy cieplnej za pomocą symulacji dynamicznych
PL
Moc cieplna zamówiona wyznaczona zgodnie z normą PN-EN 12831 okazuje się zbyt duża w późniejszej eksploatacji budynku. W artykule przedstawiono analizę obliczenia mocy do ogrzewania budynku domu studenckiego trzema metodami: zgodną z normą oraz wykorzystując symulacje dynamiczne z użyciem standardowych i zmienionych danych klimatycznych. Pokazano, że w porównaniu z metodą statyczną, zapotrzebowanie na moc jest o przeszło 20% mniejsze w przypadku analizy dynamicznej, gdy przyjęto stałą temperaturę powietrza zewnętrznego -20°C, oraz prawie 40% mniejsze w przypadku wykorzystania standardowych danych meteorologicznych.
EN
The designed heat load is determined in accordance with the PN-EN 12831 standard, but in later operation it turns out that the power determined in this way is too high. The article presents an analysis of the calculation of heat load for heating in a dormitory building with three methods: compliant with the standard and using dynamic simulations using standard and changed climate data. It has been shown that compared to the static method, the heat load is more than 20% lower in the case of dynamic analysis with the use of a constant outside air temperature of -20°C, and nearly 40% lower when using standard meteorological data.
7
PL
W metodologii obliczania charakterystyki energetycznej budynku obowiązującej w Polsce nie jest uwzględniane ograniczenie energii końcowej na ogrzewanie budynku wynikające z mocy źródła ciepła. W artykule zaproponowano sposób uwzględnienia tego ograniczenia, polegający na obliczaniu w każdym miesiącu sezonu grzewczego podaży energii końcowej ze źródła ciepła i zapotrzebowania na tę energię obliczanego według stosowanej dotychczas metody. Do określenia charakterystyki energetycznej powinna być przyjmowana mniejsza z tych dwu wartości. Wykazano, że nieuwzględnianie mocy źródła ciepła w przypadku oceny energetycznej budynków wzniesionych przed transformacją ustrojową w Polsce, w stanie przed termomodernizacją prowadzi do znacznego zawyżenia potrzeb energetycznych budynku. Omówiono również konsekwencje znacznej nadwyżki mocy cieplnej źródła, w stosunku do obciążenia cieplnego budynku, często występujące w budynkach, w których prace termomodernizacyjne rozpoczęto od systemu grzewczego.
EN
In the methodology of energy performance of buildings in force in Poland, the final energy limit for heating a building resulting from the heat source’s power is not taken into account. The article proposes a way to take into account this limitation, consisting in calculating for each month of heating season the final energy supply from the heat source and the demand for this energy calculated according to the method used so far. To determine the energy performance should be taken the smaller of these two values. It has been shown that the failure to take into account the power of the heat source in the case of energy assessment of buildings erected before the political transformation in Poland, in the state before thermal retrofitting leads to a significant over-estimation of the energy needs of the building. Also were discussed the consequences of a significant surplus of thermal power of the source, in relation to the heat load of the building, often occurring in buildings in which thermo-modernization works started from the heating system.
PL
Do podstawowych zagrożeń, związanych z pracą ratownika górniczego poza zagrożeniem wybuchem metanu, należą wysoka temperatura i wilgotność powietrza otoczenia, duża masa przenoszonego sprzętu. W artykule przedstawiono wyniki badań przeprowadzonych w warunkach laboratoryjnych dla dwóch wariantów stosowanego przez ratowników ubioru, aparatu ratowniczego i dwóch poziomów temperatury otoczenia. Porównano czas trwania badań do osiągnięcia limitów fizjologicznych temperatury wewnętrznej, częstości skurczów serca, bądź zakończenia badań z powodów subiektywnych. Przedstawiono różnice w intensywności pocenia, gromadzenia potu w odzieży, akumulacji ciepła i subiektywnych ocen wrażeń cielnych przy dwóch poziomach temperatury otoczenia.
EN
High levels of air temperature and humidity, the large mass of the transferred equipment are basic risks beyond the risk of explosion of methane of work-related mining rescuers. The article presents results of a research study conducted in the laboratory for two variants of clothing developed for mining rescuers and one kind of respiratory protective device at two levels of ambient temperature and moderate physical work intensity. A duration of the exercise to achieve the physiological limits of the internal temperature, heart rate or completion of the study because of subjective reasons was compared between studies conducted at two levels of air temperature. Differences in the intensity of sweating, level of sweat accumulated in clothing, heat accumulation and subjective ratings of the thermal state at mentioned variants of environment conditions were also described.
PL
W artykule porównano cztery znane metody obliczeniowe wykorzystywane do określania zysków ciepła od oświetlenia elektrycznego dla pomieszczeń użyteczności publicznej, w których zamontowano okna lub świetliki. Porównanie dotyczy tylko takich pomieszczeń, które nie są wykorzystywane w sposób ciągły, a co za tym idzie współczynnik akumulacji jest mniejszy niż 1. Dla potrzeb przeprowadzenia analizy przyjęto, że pomieszczenie mają okna wyeksponowane na różne strony świata. Porównano wyniki wartości zysków ciepła od oświetlenia elektrycznego w odniesieniu do bilansu ciepła jawnego uzyskiwanych dla poszczególnych metod w funkcji zastosowanego rodzaju oświetlenia oraz kierunku względem stron świata. Analizie poddano typowe oświetlenie żarowe, halogenowe, świetlówkowe oraz typu LED. Omówiono metody obliczeniowe oraz ich wpływ na końcowe wyniki dotyczące wyznaczania strumienia powietrza wentylującego.
EN
Article compares four known methods for calculating heat load coming from electrical lights in public use buildings equipped with windows and roof skylights. Comparison refers to rooms not beeing in constant use so their accumulation factor is less than 1. Analysed rooms have windows directd to different points of compass. Article compares the values of electrical lights heat load in reference to the value of sensible heat balance achieved using particular calculation methods as a function of different kinds of electrical light and different points of compass. Article analysed typical incandescent light bulbs, fluorescent and LED lights. Study describes calculation methods and their influence on the results of selected air volume.
EN
As a result of the increase in the world population and the decrease in agricultural land, the need for food increases every day. Nowadays, breeding studies are carried out to increase the yield of plants to get more products from the same area. Furthermore, controlled production areas are created by optimizing climatic conditions and the continuity of production is ensured. It is called greenhouse, where production can be carried out throughout the year and the indoor temperature and humidity conditions can be controlled. Nowadays, greenhouses are now functioning as an industrial enterprise. However, greenhouses need to comply with the principles of quality production, efficient income growth and physical environmental protection. Almost all of the plant production in greenhouses in Turkey is done in the Mediterranean region, but in the Southeastern Anatolia Region, it is done in a very limited greenhouse area. The increase of protected agricultural areas in the Mediterranean region and the fact that the production volume cannot reach a certain limit makes it necessary to investigate alternative protected production areas. In this study, climate conditions of Antalya province and climate data of four provinces of the Lower Euphrates basin are compared with each other and statistically compared. As a result of, differences have been found between Antalya province and the provinces in the Lower Euphrates basin in terms of minimum, maximum, and average temperatures. However, there is no difference between the provinces in the basin except for Gaziantep in terms of climatic conditions. Therefore, it has been determined that Gaziantep province is not suitable for greenhouse cultivation. However, it has been concluded that if greenhouse cultivation is performed in this province, it is appropriate to perform cultivation in the areas where alternative energy sources can be used. It has been concluded that in the case that heating costs are reduced using alternative energy sources, Şanlıurfa and Kilis provinces are climatologically suitable for greenhouse cultivation and Adıyaman province is partially suitable for it.
PL
W artykule porównano cztery znane metody obliczeniowe dotyczące wyznaczania zysków ciepła od oświetlenia elektrycznego dla pomieszczeń użyteczności publicznej, które nie są wykorzystywane w sposób ciągły. Na potrzeby analizy przyjęto, że pomieszczenie nie ma oświetlenia naturalnego. Porównano wyniki wartości zysków ciepła uzyskiwanych dla poszczególnych metod w zależności od zastosowanego rodzaju oświetlenia. Analizie poddano typowe oświetlenie żarowe, halogenowe, świetlówkowe oraz typu LED. Dla przykładowego pomieszczenia obliczono zyski ciepła od oświetlenia elektrycznego oraz bilans ciepła jawnego a następnie wyznaczono wymagany dla pomieszczenia strumień powietrza wentylującego. Wyniki obliczeń przedstawiono na odpowiednich rysunkach. Omówiono metody obliczeniowe oraz ich wpływ na końcowe wyniki dotyczące strumienia powietrza wentylującego.
EN
Paper compares four known calculation methods applied to electrical lighting heat load estimation for public use, non permanently occupied rooms. For the needs of analysis it was adopted that the rooms have no natural source of light. Paper compares results of heat load value given by particular calculation methods depending on electric light system. Analysis was carried out for incandescent, halogen, fluorescent tubes and LED lighting systems. Example room was examinated against electrical lighting heat load, sensible heat balance and finally, required ventilation air volume. Calculation results are given in appropriate pictures. Paper discusses calculation methods and their influence on final results regarding ventilation air volumes.
PL
Zaproponowano modelowanie zjawisk przepływowo-cieplnych występujących w rurach gładkich oraz wewnętrznie ożebrowanych. Proponowany model oparty jest na rozwiązaniu równań bilansowych opisujących zasady zachowania masy, pędu i energii, który pozwala na analizowanie procesów nieustalonych. Jest to model o parametrach rozłożonych. Celem obliczeń jest m.in. wyznaczenie rozkładu entalpii, strumienia masy oraz ciśnienia czynnika wewnątrz rur gładkich i ryflowanych oraz współczynnika wnikania ciepła. Analizie poddano rury w układzie pionowym pracujące przy nadkrytycznych parametrach pary. Otrzymane wyniki obliczeń numerycznych porównane zostaną z wynikami otrzymanymi za pomocą modelowania CFD.
EN
Proposed is modeling of flow and thermal phenomena occurring in smooth and inner finned tubes. The model is based on solving balancing equations describing rules concerning mass, momentum and energy conservation that enable analysis of transient processes. It is a model of distributed parameters. The purpose to make those calculations is i.a. determination of enthalpy distribution, mass stream, pressure of medium inside smooth and inner finned tubes and the heat transfer coefficient. The analysis was performed for vertical system tubes working in supercritical steam parameters. The results obtained in the way of numerical computations will be compared to the ones obtained with the help of CFD modeling.
EN
The influence of the CO2 concentration in a local air zone in naturally ventilated residential houses on the residents’ behaviour was numerically investigated. A numerical two-dimensional CFD model of the indoor zone based on experiments performed by the authors was used. Different resident locations in the fluid domain and different inlet velocities imposed by wind were considered in simulations. The overall thermal comfort and IAQ indices were also calculated. The investigations results show that in contrast to the overall air quality, the local CO2 was strongly dependent upon the resident location, fresh air inlet velocity and ventilation system type.
EN
Studies of the energy deposition by plasma jets incident on a material surface are of topical interest for both the fusion and plasma technology applications. In this paper the results are reported of a comparative study of plasma energy deposition on different material surfaces exposed to plasma jets of various duration and energy density, generated using the QSPA Kh-50 and the MPC devices. The spatial distribution of plasma energy density and the heat load on the surface were measured with a movable calorimeter. The measurements demonstrate that in the case of an exposure to QSPA plasma jets the absorbed heat load is approximately equal to 55-60% of the energy in the incident plasma jet. In the case of plasma jets generated using the MPC device the heat load on the target surface and was practically the same as for the QSPA jets, and additional shielding effects were found to be negligible due to the short duration of plasma jets.
EN
Coppicing is uncommon in Poland; however, some remnants of a previously coppiced oak forest persist in the foothills of the Sudety Mountains (southern Poland). Some of these forests are considered as a kind of thermophilous oak forest, classified as habitat 91I0 in the European programme Natura 2000. As an example of previously coppiced sessile oak (Quercus petraea (Matt.) Liebl.) forest in Poland, the vegetation and environmental factors in the "Wąwóz Lipa" reserve (area 101 ha, altitude ca. 400 m a.s.l.) were surveyed. Canonical correspondence analysis showed a basic compositional gradient of vegetation related to the content of coarse fragments in the soil, light availability and soil pH. The number of species per plot was not correlated with any particular environmental variable; in general, the plant species number and cover decreased in the most exposed sites, where the heat load was highest. We hypothesize that the higher number of species in some plots was the results of an edge effect: this occurred in transitional zones between the most exposed sites, which work as refuges for light-demanding, drought-tolerant species, and less exposed sites, with vegetation typical of acidophilous oak forests. The land relief also allowed the spread of species typical of mesophilous forests, which found refuge in the shaded, wet gorges. Thus, the specific land relief, along with previous coppice management, allowed the coexistence, probably temporally, of species of plants considered typical of different habitats.
PL
Artykuł porusza problem prawidłowego uwzględnienia pojemności cieplnej budynku w obliczeniach obciążenia cieplnego. Opisuje także sposoby wyznaczania masy budynku oraz wpływ błędnego jej wyznaczenia na wartość obciążenia cieplnego.
EN
The paper describes problems with proper use of heat capacity in heat load calculation. The paper also describes calculation methods of heat capacity and its influence on heat load value.
PL
W artykule przedstawiono zasady oceny obciążenia cieplnego człowieka w zimnym środowisku dotyczące zarówno wychłodzenia ogólnego, jak i lokalnego. Opisano też czynniki wpływające na zróżnicowanie wymagań pracowników odnośnie ciepłochronności odzieży ochronnej. Wyszczególniono czynniki pozwalające zachować równowagę cieplną w zimnym środowisku.
EN
This article presents the principles of assessing thermal load in a cold environment. It also discusses why different workers require different thermal insulation of protective clothing. Elements that help to maintain thermal balance in a cold environment are listed.
EN
In order to adjust Polish regulations to the Energy Performance of Building Directive, new requirements have been introduced to Polish legislation. The well known Polish Standard PN-B-03406:1994 has been replaced by new PN-EN 12831 which raises a lot of controversies especially regarding the final results of heat load calculations based on the described procedures. The paper indicates possible discrepancies in calculation results arising from imprecise guidelines and the consequences of relying on the results gained by the described method. Additionally, later aspects of the system operation and their negative influence on the estimated efficiency level and CO2 emission have been analyzed.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.