Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  heat exchanger efficiency
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This study utilized two double tube-type heat exchangers. The first exchanger employed a smooth inner tube, while the second one utilized a twisted inner tube. The shell was constructed of plastic (PVC), while the tube was made of copper with a length of 1000 mm, an outer diameter of 62.24 mm, a smooth tube inner diameter of 14.2 mm, and an equivalent diameter of 11.8 mm for the twisted tube. To minimize heat loss, the shell was insulated externally with a thermal insulator. A flow rate of 3 liters per minute of hot water was passed through a ring-shaped tunnel, with an inlet temperature of 63 °C, to enhance the heat exchanger's performance. The experimental results of the two heat exchangers (smooth and twisted inner tubes) were compared, and the use of water as the primary fluid led to improved performance. The twisted inner tube-type heat exchanger achieved a maximum efficiency of 0.33 at a volumetric flow rate of 5 liters per minute, while the maximum improvement in effectiveness was 65.71% at a volume flow rate of 3 liters per minute in the twisted inner tube-type heat exchanger.
PL
W badaniach wykorzystano dwa dwururowe wymienniki ciepła. W pierwszym wymienniku zastosowano gładką rurę wewnętrzną, natomiast w drugim zastosowano rurę skręconą. Płaszcz wykonano z poli(chlorku winylu) (PVC), natomiast rura wykonana z miedzi charakteryzowała się następującymi wymiarami: długość 1000 mm, średnica zewnętrzna 62,24 mm, średnica wewnętrzna 14,2 mm i średnica zastępcza dla rury skręconej 11,8 mm. Aby zminimalizować straty ciepła, rura została zaizolowana od zewnątrz izolatorem termicznym. Aby poprawić wydajność wymiennika ciepła, przez tunel w kształcie pierścienia przepuszczano gorącą wodę z szybkością 3 dm3/min., a temperatura na wlocie wynosiła 63°C. Porównano wyniki eksperymentalne dwóch wymienników ciepła (gładkiego i o skręconej rurze wewnętrznej) i stwierdzono, że zastosowanie wody jako płynu roboczego doprowadziło do poprawy wydajności wymiennika. Wymiennik ciepła wykonany ze skręconej rury wewnętrznej osiągnął maksymalną wydajność 0,33 przy objętościowym natężeniu przepływu 5 dm3/min., natomiast maksymalna poprawa efektywności wyniosła 65,71% przy objętościowym natężeniu przepływu 3 dm3/min.
PL
Jednym z ważnych elementów procesu projektowania jest zapewnienie optymalnego zużycia energii w trakcie wytwarzania i późniejszej eksploatacji urządzenia lub systemu. W artykule przedstawiono porównanie wydajności wymienników ciepła urządzenia wentylacyjnego z chłodzeniem powietrza w okresie ciepłym, obsługującego takie samo pomieszczenie, lecz w 13 różnych lokalizacjach na terenie Polski. Porównano także statystyczne zapotrzebowanie energii do uzdatniania powietrza. Do analizy pracy wymienników przyjmowano warunki zewnętrzne i średnie czasy trwania temperatury powietrza zewnętrznego, opublikowane przez Ministerstwo Transportu i Gospodarki Morskiej oraz parametry powietrza według normy PN-76/B-03420. Wykazano istotne różnice w wydajności wymienników, wynikające z różnych wartości parametrów powietrza zewnętrznego w podanych źródłach dla różnych regionów kraju.
EN
The optimum and rational use of energy in production and operation is an important aspect of ventilation and air-conditioning system design. This paper presents a comparative analysis of heat exchanger output in ventilation and air-conditioning systems designed to service identical compartments in 13 various locations in Poland. Statistical comparison of energy demand of air treatment was conducted. For the purpose of heat exchangers output analysis, average external conditions and average duration of outside air temperature were used, as published by the Ministry of Transport and Maritime Economy, as well as air parameters defined in PN-76/B-03420. Significant differences were observed in work output and energy use of air treatment processes, due to variances of outside air parameters quoted by the above sources per region.
PL
W pierwszej części artykułu zostanie przedstawiony model matematyczny pośredniego, regeneracyjnego wymiennika wyparnego o perforowanej powierzchni przegrody oddzielającej kanał suchy od mokrego. W artykule tym przedstawiono algorytm obliczeniowy opisujący procesy mieszania się strumienia pomocniczego ze strumieniem głównym w roboczych kanałach rekuperatora. W następnej części artykułu przedstawione zostaną wyniki symulacji numerycznej.
EN
The first part of following paper presents a mathematical model of indirect evaporative regenerative heat exchanger with perforated plate surface separating the dry and wet channel. Calculation algorithm describing the process of mixing the secondary and main streams in the working channel is shown. In the next part of following paper the results of numerical simulation will be presented.
PL
W poprzedniej części artykułu zaprezentowano model matematyczny opisujący perforowany pośredni wymiennik wyparny o regeneracyjna schemacie przepływu powietrza. W tej części artykułu przedstawiono wyniki symulacji komputerowej obrazującej procesy wymiany ciepła i mass z uwzględnieniem zjawiska mieszania się strumienia suchego i mokrego w pomocniczych kanałach.
EN
In the previous part of this article a mathematical model describing the perforated indirect evaporative heat exchanger with regenerative flow diagram was presented. This part presents the results of a computer simulation illustrating (he processes of heat and mass transfer phenomena, taking into account the mixing of wet and dry streams in the secondary channels.
PL
W pracy przedstawiono możliwości odzysku ciepła w instalacjach wentylacyjnych i klimatyzacyjnych z wykorzystaniem rekuperacji. Omówiono efektywności energetyczne poszczególnych rozwiązań oraz zaprezentowano sposób określenia tej efektywności. Wykonano obliczenia dla dwóch typów wymienników ciepła: rura w rurze oraz wymiennika płytowego. Wyznaczono ich efektywności eksperymentalnie.
EN
The paper presents the possibility of heat recovery in ventilation and air conditioning. There are discussed energy efficiency of individual solutions and demonstrates how to determine the effectiveness. The are shown calculations for two types of heat exchangers, duble-pipe type and plate. Their effectiveness was also determined experimentally.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.