Renewable energy sources especially solar energy connected to an electrical grid system by using power electronic devices, known that devices degrade the power quality and especially generate harmonic currents. This article presents the study investigation and propagation of harmonics in the integration system of an electric grid connected to the photovoltaic system in the presence or not of a non-linear load (polluting load). In this study, the perturb and observe type MPPT controller for the boost converter and the PWM control for the three-phase inverter which provides the connection are used. We use a passive filtering technique (single and multiple filters) to mitigate the harmonic currents generated by the non-linear load. In the first case where the integration system is alone, the results obtained show that the values of the total harmonic distortion (THD) rates are within the standard used. But in the case of the presence of the non-linear load, the THD values are higher than the used norm. After using our proposed technique, the values of THD obtained are in the norm used for the application of a tuned filter at the fifth harmonic, and better results find with using of multiple filters (fifth and seventh).
EN
Harmonic issue in the wind power plant is a concerning problem for both consumers and producers as that it affects the power quality of the distribution systems. This paper presents an improved control strategy for harmonic current compensation in wind turbine-based DFIG connected to the grid, using RIP-ADALINE for harmonic currents detection. A vector control-based fuzzy logic controller is applied to improve the active and reactive power flow. The active filtering is achieved using the grid side converter of the DFIG. The studied system has been simulated using MATLAB/SIMULINK platform. The results obtained show the effectiveness of the control strategies applied to the system Therefore the power quality in terms of grid current waveform, total harmonic distortion (THD) factor; frequency spectrum, and system power factor is improved within permissible standard values as defined by IEEE-519.
PL
Zagadnienia harmoniczne w elektrowni wiatrowej stanowią problem zarówno dla odbiorców, jak i producentów, ponieważ wpływają na jakość energii elektrycznej w systemach dystrybucyjnych. W artykule przedstawiono udoskonaloną strategię sterowania kompensacją harmonicznych prądu w elektrowni wiatrowej DFIG podłączonej do sieci, wykorzystującą RIIP-ADALINE do wykrywania harmonicznych prądu. Do poprawy przepływu mocy czynnej i biernej zastosowano sterownik wektorowy oparty na logice rozmytej. Filtracja czynna jest realizowana przy użyciu przekształtnika DFIG podłączonego do sieci. Badany system jest symulowany przy użyciu platformy MATLAB/SIMULINK. Uzyskane wyniki wskazują na skuteczność zastosowanych strategii sterowania, dlatego jakość energii elektrycznej w zakresie kształtu przebiegu prądu sieciowego, współczynnika całkowitych zniekształceń harmonicznych (THD), widma częstotliwości oraz współczynnika mocy systemu została poprawiona w zakresie dopuszczalnych wartości standardowych określonych przez IEEE-519.
EN
The paper presents performance comparison of harmonic filters for the reduction of harmonic distortion in an industrial power system, i.e., National Tobacco Enterprise, an industry found in Ethiopia. The performance comparison is done for single tuned, double tuned, high pass and Ctype harmonic filter. As a result, the double tuned harmonic filter provides a better performance than the other type of filters by giving a reduced Total Harmonic Distortion for the voltage and current waveforms. MATLAB/SIMULINK simulation results are presented for validating the analysis.
PL
W artykule przedstawiono porównanie wydajności filtrów harmonicznych do redukcji zniekształceń harmonicznych w przemysłowym systemie elektroenergetycznym, tj. National Tobacco Enterprise, przemysł znajdujący się w Etiopii. Porównanie wydajności jest dokonywane dla pojedynczego strojonego, podwójnie strojonego, górnoprzepustowego i typu C filtra harmonicznego. W rezultacie podwójnie dostrojony filtr harmonicznych zapewnia lepszą wydajność niż inne typy filtrów, zapewniając zmniejszone całkowite zniekształcenie harmoniczne dla przebiegów napięcia i prądu. Przedstawiono wyniki symulacji MATLAB/SIMULINK w celu weryfikacji analizy.
4
Content available remote Analysis of earth faults in the MV grid using the EMTP-ATP program
EN
The paper presents a simulation model of short circuit arc in the EMTP-ATP program. Earth fault simulation in medium voltage grid was performed. A comparison of arc faults has been made, depending on neutral point operating mode of the network. The occurrence of higher harmonics during arcing has also been investigated. Obtained results by computer simulation were presented and analyzed.
PL
W pracy przedstawiono model symulacyjny zwarcia łukowego w programie EMTP-ATP. Przeprowadzono symulacje zwarć doziemnych w sieci SN. Dokonano porównania zwarć łukowych w zależności od sposobu pracy punktu neutralnego sieci. Zbadano również występowanie wyższych harmonicznych podczas zwarcia łukowego. Przedstawiono oraz przeanalizowano otrzymane wyniki, uzyskane drogą symulacji komputerowej.
5
Content available remote Analiza napięć i prądów pobieranych przez zespół pomp wodociągowych
PL
Praca dotyczy pomiarów i analiz napięć oraz prądów pobieranych przez zespół pomp wodociągowych. Zespół składa sie z czterech pomp napędzanych silnikami indukcyjnymi z regulowaną prędkością obrotową, pracujących w układzie wędrującego falownika. Analizie poddano różne punkty pracy układu wymuszając tym samym jego funkcjonowanie w różnych konfiguracjach, wymagających pracy różnej liczby pomp oraz silników. Oceniono stopień odkształcenia prądu w badanych punktach, wykorzystując do tego celu analizy czasowe oraz częstotliwościowe. Badania wykonano na specjalnie przygotowanym stanowisku laboratoryjnym, wykorzystując do rejestracji napięć oraz prądów analizator jakości energii Elspec BlaxBox4500 oraz dedykowane oprogramowanie.
EN
The work concerns the measurement and analysis of voltage and current drawn by the water supply pump station. The set consists of four pumps driven by induction motors with adjustable speed, working in the system of a traveling inverter. Various work points of the system have been analyzed, thus forcing its functioning in various configurations requiring the work of various numbers of pumps and engines. The degree of current distortion in the tested points was evaluated using time and frequency analyzes for this purpose. The tests were carried out on a specially prepared laboratory bench, using the Elspec BlaxBox4500 energy quality analyzer and dedicated software to record voltages and currents.
6
Content available remote Variable Speed Drive (VSD) – towards modern industry and electric power systems
EN
High-power motor drives play an important role in present-day power systems. Due to high requirements put on drive systems, particularly strong development has been observed in recent years in variable speed drives (VSD), with power converters as their key part. This article reviews topics related to VSD systems, with particular focus on VSD applications, converter configuration and the harmonics injected to the grid.
PL
We współczesnych systemach elektroenergetycznych istotną rolę odgrywają układy napędowe dużej mocy. Wysokie wymagania stawiane układom napędowym powodują, że w ostatnich latach szczególnie rozwijane są układy Variable Speed Drive (VSD), których kluczowym elementem jest przekształtnik mocy. W tym artykule przedstawiony został przegląd zagadnień dotyczących układów VSD, przy czym uwaga została skupiona na kwestiach zastosowań VSD, konfiguracji przekształtników oraz harmonicznych wprowadzanych do sieci elektroenergetycznej.
7
Content available remote Sterowanie multiskalarne pięciofazową maszyną indukcyjną
PL
Zastosowanie przekształcenia układu współrzędnych fazowych na układ ortogonalny dla pięciofazowego silnika indukcyjnego o uzwojeniach skupionych prowadzi do wystąpienia w modelu matematycznym dwóch par składowych alfa-beta wektorów wirujących w dwóch nieruchomych układach współrzędnych. Pierwszy układ współrzędnych odpowiada zmiennym pierwszej harmonicznej, drugi – zmiennym trzeciej harmonicznej. Dla każdego układu występuje oddzielny zbiór parametrów maszyny a składowe wektora wirującego w jednym układzie współrzędnych nie oddziałują na pochodne składowych w drugim układzie. Zastosowanie nieliniowej transformacji pozwala uzyskać dwa modele multiskalarne, oddzielnie dla każdego z układów współrzędnych. W referacie zaproponowano sterowanie multiskalarne pozwalające na wymuszanie zadanej amplitudy i fazy trzeciej harmonicznej strumienia wirnika zwiększając tym samym wykorzystanie materiału konstrukcyjnego maszyny.
EN
The application of the transformation of phase coordinate system into orthogonal coordinate system to the five phase induction motor with concentrated windings results in mathematical model of the two pairs of alpha-beta components of two vectors rotating in a stationary frame. The first coordinate system corresponds to the third harmonic variables while the second coordinate system corresponds to the third harmonic variables. For each coordinate system there exist a separate set of machine parameters. The components of the vector rotating in one coordinate system do not affect the component derivatives of the vector rotating in the second coordinate system. The application of the nonlinear transformation allows for obtaining two multiscalar models, separately for each of the coordinate systems. The paper proposes novel multiscalar control that allow forcing the command magnitude and phase of third harmonic rotor flux thereby increasing the utilization of the construction material of the five phase machine.
8
EN
Often, in the case of a significant level of electromagnetic disturbance in electrical power system, at the customer's supply terminals, there is a need for locating the source of this disturbance, e.g. harmonics, voltage fluctuations, voltage dips, occasionally also asymmetry. Utilities and power consumers have become increasingly interested in quantifying the responsibilities for power quality problems. This issue gains particular meaning when formulating contracts for electric power supply and enforcing, by means of tariff rates, extra charges for worsening the power quality. This paper concerns as an example an application of one method (from the collection of many existing) used to locate sources of electromagnetic disturbances (harmonics, dips, voltage fluctuations and asymmetry), based on the study of the power flow at the point of common coupling (PCC).
PL
Często w przypadku wystąpienia znaczącego poziomu zaburzenia elektromagnetycznego na zaciskach odbiorcy powstaje potrzeba lokalizacji jego źródła, przykładowo harmonicznych, wahań napięcia, zapadów napięcia, niekiedy także asymetrii. Dostawcy i odbiorcy energii w coraz większym stopniu są zainteresowani jednoznaczną oceną odpowiedzialności za złą jakość dostawy energii. Nabiera to szczególnego znaczenia w okresie formułowania kontraktów na dostawę energii i egzekwowania, poprzez taryfy, opłat za pogarszanie jej jakości. W artykule przedstawiono, jako przykład, aplikację jednej metody (ze zbioru wielu istniejących) stosowanej do lokalizacji źródeł zaburzeń elektromagnetycznych (harmonicznych, zapadów, wahań i asymetrii napięcia) opartej na badaniu kierunku przepływu mocy w punkcie wspólnego przyłączenia (PWP).
9
Content available remote Minimization of Leading Current in a Three Phase Four Wires Shunt Hybrid Filter
EN
The main drawback of Shunt Hybrid Filters is the need of leading current injection. This paper describes a strategy to reduce the leading current in a three phase four wires LC coupled parallel hybrid filter for harmonics cancellation. Simulation and experimental results are given to show the behaviour of the system.
PL
Główną wadą równoległych filtrów hybrydowych jest potrzeba wstrzykiwania prądu pojemnościowego. W artykule opisano strategię sterowania prowadząca do zmniejszenia prądu pojemnościowego w trójfazowym czteroprzewodowym filtrze hybrydowym sprzężonym z siecią za pomocą obwodu LC, przeznaczonym do eliminacji harmonicznych. Właściwości badanego systemu zilustrowano wynikami symulacyjnymi i eksperymentalnymi.