Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  grunty słabonośne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
Wyniki badań nad samowzmocnieniem gruntu słabonośnego po instalacji kolumn metodą przemieszczeniową. Wpływ uwzględnienia samowzmocnienia na pracę kolumn wzmacniających w systemie GEC (Geosynthetic Encased Column).
EN
The results of research work on the effect of self-strengthening of soft soil after installation of columns using displacement method. Impact of the effect of self-strengthening of soft soil on design process and behaviour of GEC (Geosynthetic Encased Column) system.
PL
W artykule zamieszczono opis stosowanych na terenie Rzeszowa w obrębie Pradoliny Podkarpackiej metod fundamentowania. Sposoby posadowienia obiektów stosowane w przeszłości porównano z rozwiązaniami dominującymi obecnie. Wskazano na zalety i niedoskonałości różnych rozwiązań fundamentowych. W kontekście specyfiki warunków gruntowo-wodnych występujących w Rzeszowie zwrócono uwagę na alternatywny sposób posadowienia pośredniego za pomocą pali rzeszowskich – koncepcji opracowanej przez prof. Jana Jaremskiego. Wspomniane rozwiązanie zostało z powodzeniem zastosowane w praktyce i wiele wskazuje na to iż, obecna metodyka określania nośności fundamentów pośrednich znacząco niedoszacowuje możliwości przenoszenia obciążeń przez takie fundamenty.
EN
The paper presents a description of the foundations used in Rzeszów on Podkarpacie icemarginal valley area. The methods of building foundation used in the past were compared to those dominant currently. The advantages and limitations of the various foundation solutions were indicated. In the context of the specific soil and water conditions occuring in Rzeszów, attention was directed to the alternative method of indirect foundation. New approach is Rzeszow piles - a concept developed by prof. Jan Jaremski. This solution was been successfully applied in practice. A many point to the fact that the current methodology for determining the bearing capacity of indirect foundations was underestimated for possibility of the load transferability by such foundations.
EN
Design and problems of erection of bridge founded on weak deformable soil are presented. Foundation on piles was impossible due to to large thickness of weak soil layer. That is why the bridge supports were placed on continuous footings. The soil layer of significant thickness, located the footings, was replaced. Since design computations proved that non-uniform settlements may occur, statically determinate structure was chosen (beam with hinges). It eliminated negative influence of non-uniform support settlements on structural behavior. Non-typical hinge solutions was applied - without expansion joints. Effectiveness of applied solutions was proved during bridge exploitation.
PL
W artykule przeanalizowano zmiany wartości gradientu hydraulicznego w zależności od wartości przyłożonego obciążenia zewnętrznego na słabonośne podłoże organiczne. Analizę zmian przedstawiono w funkcji prędkości przepływu wody oraz wskaźnika porowatości, którego wysoka początkowa wartość, jak wykazały badania w podłożu torfowym, znacząco maleje wraz we wzrostem naprężeń konsolidacyjnym. Analizę przeprowadzono na wynikach badań przepływu wody w słabonośnym ośrodku porowatym wykorzystując metodę flow-pump, tj. stałego, wymuszonego przepływu.
EN
In this review paper the changes of hydraulic gradient in the flow characteristics is presented. The analysis has been obtained in the value of loaded effective stress in soft soil. The relationship between fl ow velocity and hydraulic gradient is nonlinear. The results of soft soils used to the analysis were obtained in laboratory using the flow-pump technique. To describe the permeability characteristics the prelineary and postlineary phases should be considered. The prelineary phase characterises the flow at very low hydraulic gradient which usually appears in situ. The permeability characteristics show the strong changes of hydraulic gradient under different values of effective stress.
EN
This paper reviews laboratory methods for measuring the stress-strain-strength-flow behaviour of soft clays for determination of design parameters. It describes three levels of testing from simple classification tests to advanced testing for measurement of design parameters. The paper traces some of the major practical contributions of experimental research to our understanding of soft clay mechanical behaviour. Recommendations are given for implementation of these research results in practice with the goal of improving the engineering state-of-the-practice, which often lags well behind the research state-of-the-art. Significant advances in the understanding of clay behaviour have been realized in the past few decades including such issues as the influence of anisotropy, stress history, rate effects, and sample disturbance. Of these issues, sample disturbance remains by far the most difficult one to deal with in practice and in fact is often ignored. It is recommended that evaluation of sample disturbance be considered an essential aspect of any site characterization program.
6
Content available remote In situ testing of soft Brazilian soils
EN
An overview of in situ tests performed on soft Brazilian soils is presented. Special emphasis is given to the Sarapui test site and to the test sites in Rio de Janeiro of very high plasticity. Some lessons related to the use of a piezocone with two filters are presented.
7
Content available remote In situ shear wave velocity from MASW surface waves at Norwegian soft clay sites.
EN
The Multichannel Analysis of Surface Waves (MASW) technique, used to determine shear wave velocity (Vx) and hence small strain stiffness (Gmax), has recently generated considerable interest in the geophysics community. This is because of the ease of carrying out the test and analysis of the data. The objective of this work was to assess the repeatability, accuracy and reliability of MASW surface wave measurements for use in engineering studies. Tests were carried out at 5 well-characterized Norwegian soft clay research sites where Vs had already been assessed using independent means. As well as being easy and quick to use MASW gave consistent and repeatable results. The MASW Vs profiles were similar to those obtained from other techniques. This work also confirms that MASW Vs clay profiles are comparable to those obtained by correlation with CPT. For these sites there also seems to be a good correlation between normalized small strain shear modulus and in situ void ratio or water content and the data fit well with published correlations for clays.
8
Content available remote Experience with CPTU, T-bar and ball penetrometers in two soft clays.
EN
Field developments in deep waters with very soft soils have led to increased reliance on the use of in situ tests to evaluate soil design parameters. Recently the T-bar and ball penetrometers have been introduced due to their potential for increasing the reliability of interpreted undrained shear strength relative to the CPTU for soft clays. Empirical correlations based on field tests and laboratory tests on samples at two onshore soft clay sites indicate that T-bar correlation factors are in a somewhat narrower range compared to cone factors. Recommendations are given in terms of cone and T-bar factors to use.
PL
Jednym z istotnych efektów projektu badawczego KBN Nr TO7E 01012 [1], kierowanego w latach 1996-1999 przez Profesora S. Pisarczyka, było opracowanie projektu i wykonanie prototypu nowej sondy obrotowej, nazwanej piezosondą PZO-1 [2], która umożliwia podczas ścinania gruntu in situ pomiary dodatnich i ujemnych (ssanie) ciśnień wody w porach. Pomiary ciśnień przeprowadzane są za pomocą dwóch niezależnych układów tensjometrycznych, rozpoczynających się ceramicznymi krążkami na przeciwległych powierzchniach jednego ze skrzydełek sondy. Wartości ciśnień wody w porach umożliwiają kontrolę stanu naprężeń efektywnych, który uwzględniany jest w interpretacji wyników badań. Artykuł zawiera opis konstrukcji sondy, jej możliwości i ograniczenia oraz perspektywy określania dodatkowych danych, cennych dla rozpoznania warunków geotechnicznych projektowanych budowli. Perspektywy te dotyczą badań gruntów nienasyconych, określania położenia zwierciadła wody gruntowej i charakterystyk hydraulicznych gruntów słabonośnych.
EN
The new PZO-1 piezovane, capable of pore pressure measurements, solves one of the most recalcitrant problems faced by foundation engineers, namely; finding the on-site characteristics of compressible soils, in particular organie soils such as peat and organic clays. This paper describes the construction, features and functions of the PZO-1, together with measurement procedures and the interpretation of results for relative to their stress distribution and history. Some pilot test results on peat deposits in the Biebrza valley are also included. The interpretation of the measurements of hydrostatic pressure prior to shearing and pore pressure during shearing shows that the PZO-1 supplies far more of the data required for foundation design than existing probes.
PL
Posadowienie budowli często sprawiało budowniczym dużo problemów i od początków dziejów są znane przypadki niewłaściwych działań prowadzących w konsekwencji do awarii, a nawet katastrof. Do bezpiecznego zaprojektowania fundamentów potrzebna jest nie tylko wiedza praktyczna i intuicja, ale też teoretyczna znajomość zachowania się rzeczywistego ośrodka. Projektowanie fundamentów wymaga też spełnienia innych kryteriów, zwłaszcza ekonomicznych, do których należy zaliczyć m.in. koszty budowy wraz z kalkulacją strat spowodowanych ewentualną awarią obiektu i ewentualnej katastrofy. W niektórych przypadkach czynnikiem determinującym projektowane rozwiązanie może być występowanie w podłożu warstwy kulturowej, zawierającej pozostałości po dawnych obiektach przedstawiających obecnie wartość archeologiczną. W pracy rozważono różne warianty fundamentowania dwóch 3 kondygnacyjnych budynków mieszkalnych, posadowionych na słabonośnej warstwie kulturowej. Przeprowadzono analizę kilku sposobów posadowienia, wybierając w standardowy sposób rozwiązanie optymalne.
EN
The foundation of the considered building constitute the cultular layer including numerous remains of the former objects. The cultular layer occurs at the depth of up to 4,5m below the ground level while sandy ground occurs only below 6,3 m. It requires the application of different solutions than continuous footing. Several methods of foundations have been suggested and the wells have been hosen as the finał solution which does not destroy the cultular layer and is simple, cheap and reliable. Labour force and avaiable elements are enough to realise that. The elaboration deals with the object situated in Main City of Gdańsk.
first rewind previous Strona / 1 next fast forward last