Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  groundwater treatment
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper concerns the experimental research related to the removal of color and permanganate index (CODMn) in the presence of iron and manganese from the underground water by means of coagulation and ozonation. The tests were carried out on a laboratory and technical scale in the real underground water treatment system. Ozone, as a strong oxidizing agent, was used to reduce the color intensity and to convert the iron Fe2+ and manganese ions Mn2+ to Fe(OH) 3 and MnO2, respectively. In order to optimally remove the color to a value below 15 mg/L, the ozone dose of 3 mg/L was sufficient, which also ensured the proper removal of iron and manganese, by 94% and 83%, respectively. However, ozonation conducted under these conditions, did not provide sufficient removal of organic compounds expressed as CODMn below the assumed value of 3 mg/L. The effect of aluminum sulfate and polyaluminum chloride (PAC) was also studied, as a result of which it was found that polyaluminum chloride proved to be more effective reagent. Under the technical conditions of water purification at a dose of 16 mg/L coagulant, the efficiency of color removal was 65.2% and CODMn – 50.8%, which ensured that the values of the tested indicators in the purified water were maintained below the permissible level.
EN
The recent climate condition and pollution problem related to surface water have led to water scarcity in Malaysia. Huge amount of groundwater has been identified as viable source for drinking water. This paper was aimed to investigate groundwater’s quality at specific location and metakaolin’s potential in the groundwater treatment in the removal of manganese. Groundwater purging was determined to be sufficient at 120 minutes where all three parameters (pH, dissolved oxygen and conductivity) were stabilized. The groundwater studied is classified as both anoxic and reductive due the low dissolved oxygen value. It also can be categorized as brackish due to high value of conductivity and total dissolved solid. Manganese content in groundwater was determined as higher than of that permissible limit for raw water and drinking water which makes it unsuitable for them not suitable for consumption and cleaning purpose. Average manganese concentration in samples was 444.0 ppb where the concentrations of manganese ranged from 229.4 ppb to 760.3 ppb. Manganese developed is not that a strong positive correlation against iron concentration, total dissolved solids and conductivity; whereas has a moderate negative correlation against dissolved oxygen. The capability adsorption of manganese by metakaolin was assessed via batch method which indicated optimum dosage and contact time was 14g that removed average 30.2% and contact time optimum at 120 minutes which removed 33.2% manganese from the sample.
PL
Zgodnie z Rozporządzeniem Zdrowia z dn. 20 kwietnia 2010 r. stężenie manganu w wodzie nie może przekraczać 0,05 mg/l. Niniejsze uwarunkowanie wymusza uzdatnianie wód podziemnych i uzyskanie wymaganych stężeń. W tym celu stosowane są popularne materiały filtracyjne dostępne na krajowym rynku. Autorki w ramach badań przeprowadziły eksperymenty na dwóch złożach filtracyjnych. Pierwszym z nich była masa katalityczna G-1, drugim natomiast złoże Crystal-Right. Tym samym w niniejszym artykule przedstawiono metodykę badań, charakterystykę badanych złóż oraz wyniki badań wody, w tym zawartość w niej manganu po procesie filtracji.
EN
According to the Health Regulations of 20 April 2010, the concentration of manganese in water must not exceed 0.05 mg/l. This condition enforces the treatment of underground water and achieving the required concentrations. For this purpose, popular filter materials are available on the domestic market. The authors in the study conducted experiments on two filter beds. The first was G-1 catalytic mass, whereas the second was Crystal-Right. Thus, this paper presents the methodology of the study, the characteristics of the studied fields and the results of water tests, including the content of manganese in the process after filtration.
EN
One of the problems with iron removal from groundwater is organic matter. The article presents the experiments involved groundwater samples with a high concentration of total iron - amounting to 7.20 mgFe/dm 3 and an increased amount of organic substances (TOC from 5.50 to 7.50 mgC/dm3). The water samples examined differed in terms of the value of the ratio of the TOC concentration and the concentration of total iron (D). It was concluded that with increase in the coexistence ratio of organic substances and total iron in water (D = [TOC]/[Fetot]), efficiency of Fe(II) to Fe(III) oxidization with dissolved oxygen decreased, while the oxidation time was increasing. This rule was not demonstrated for potassium manganate (VII) when used as an oxidizing agent. The application of potassium manganate (VII) for oxidation of Fe(II) ions produced the better results in terms of total iron concentration reduction in the sedimentation process than the oxidation with dissolved oxygen.
PL
Przedmiotem badań była woda podziemna charakteryzująca się wysokim stężeniem żelaza ogólnego do 7,20 mgFe/dm3 oraz podwyższoną zawartością substancji organicznych (OWO od 5,50 do 7,50 mgC/dm3 ). Badane próbki wody różniły się wartością ilorazu stężenia OWO do stężenia żelaza ogólnego (D), udziałem stężenia Fe(II) w stężeniu Feog (C), a jej mętność i intensywność barwy wskazywały na obecność koloidalnych oraz rozpuszczonych połączeń żelaza ze związkami organicznymi. Celem badań było określenie wpływu stężenia substancji organicznych w wodzie podziemnej na skuteczność utleniania Fe(II) do Fe(III) tlenem rozpuszczonym w wodzie lub manganianem (VII) potasu, a także na skuteczność usuwania związków żelaza w procesie sedymentacji. Wykazano, że wraz ze wzrostem wartości współczynnika współwystępowania substancji organicznych i żelaza ogólnego w wodzie surowej (D) zmniejszała się skuteczność utleniania Fe(II) do Fe(III) tlenem rozpuszczonym. W próbkach wody, w których do utleniania Fe(II) stosowano manganian (VII) potasu nie stwierdzono wpływu wartości współczynnika D na skuteczność utlenienia Fe(II) do Fe(III). Zastosowanie manganianu (VII) potasu jako utleniacza zapewniło większą skuteczność usuwania związków żelaza z wody podziemnej w procesie sedymentacji niż napowietrzanie.
PL
W pracy przedstawiono wyniki badań nad skutecznością usuwania lotnych związków organicznych z wód podziemnych w procesie desorpcji. Wykazano wpływ wody i napowietrzania na usuwanie trichloroetenu (TCE) i tetrachloroetenu (PCE).
EN
The paper presents results of the research on effectiveness of volatile organic substances removal from groundwater in desorption process. In the research the influence of water and air load on the removal of trichloroeten (TCE) i tetrachloroeten (PCE) is presented.
EN
The paper presents lessons learnt from seven-year exploitation of a system for groundwater nitrate removal by biological denitrification. This process was implemented at Wierzchowisko (Mykanow, Silesian Voivodship) withdrawing water from upper Jurassic carbon deposits. Raw underground water complies with the quality recommendations for drinking water except nitrates (NO3–), which amount to about 80 gNO3–/m3 (permissible limit 50 gNO3–/m3). Nitrate removal plant opened in 2006, with capacity of 500 m3/h, comprises of the following technological installations: biofilters (kermesite bed; C2H5OH and H3PO4 dosing), aerators (FeCl3  dosing), rapid filters (kermesite bed) as well as sorption filters (WG-12 active carbon). The set of processes performed at these facilities allows 80% effectiveness in regard to groundwater nitrate removal. Due to the final ozone water disinfection, a possibility of bromate formation was noted as a result of oxidation of bromides present in the water (approx. 35 mgBr–/m3). The ozone dose was lowered in order to limit this unfavorable phenomenon and thus the bromate concentration in the purified water was reduced to <3 mgBrO3–/m3 (permissible limit 10 mgBrO3–/m3).
PL
Przedstawiono doświadczenia z siedmioletniej eksploatacji instalacji do usuwania azotanów z wody podziemnej metodą denitryfikacji biologicznej. Proces usuwania azotanów wdrożono w stacji wodociągowej „Wierzchowisko” (gm. Mykanów, woj. śląskie) ujmującej wodę z górnojurajskich utworów węglanowych. Ujmowana woda podziemna spełnia wymagania jakościowe wody przeznaczonej do spożycia przez ludzi z wyjątkiem azotanów (NO4–), które osiągają zawartość około 80 gNO3–/m3 (wart. dop. 50 gNO3–/m3). Oddana do użytku w 2006 r. stacja usuwania azotanów ma wydajność 500m3/h i składa się z następujących urządzeń technologicznych: biofiltry (keramzyt; dawkowanie C2H5OH i H3PO4), aeratory (dawkowanie FeCl3), filtry pospieszne (keramzyt) oraz filtry sorpcyjne (węgiel aktywny WG-12). Układ procesów realizowanych w tych urządzeniach pozwala na uzyskanie 80% skuteczności usuwania azotanów z wody. Z uwagi na końcową dezynfekcję wody ozonem, zwrócono uwagę na możliwość utleniania bromków obecnych w wodzie (ok. 35 mgBr–/m3) do bromianów. W celu ograniczenia tego niekorzystnego zjawiska zmniejszono dawkę ozonu uzyskując ograniczenie zawartości bromianów w wodzie oczyszczonej do <3 mgBrO3–/m3 (wart. dop. 10 mgBrO3-/m3).
7
Content available remote Usuwanie substancji organicznych z wód podziemnych
PL
Skuteczność usuwania substancji organicznych w konwencjonalnym układzie oczyszczania wód podziemnych oraz w procesie koagulacji koagulantami glinowymi: siarczanem glinu, glinianem sodu, chlorkiem poliglinu (PAX XL-60), a także koagulantem żelazowym PIX-112. Wykazano, że o skuteczności procesu koagulacji w usuwaniu substancji organicznych współdecydowały rodzaj koagulantu i jego dawka, a także temperatura, pH i wartość współczynnika współwystępowania związków organicznych i żelaza ogólnego w wodzie surowej.
EN
Removal efficiency of organic matter in conventional water treatment system of underground and in the process of coagulation aluminium coagulants: aluminum sulfate, sodium aluminate, polyaluminium chloride (PAX XL-60), and ferric coagulant PIX-112. It was shown that the effectiveness of coagulation in the removal of organic matter was determined while the type and dose of coagulant, as well as temperature, pH and the value of coexistence of organic compounds and total iron in raw water.
8
PL
W artykule przedstawiono najczęściej stosowane procesy w barierze aktywnej technologii PRB. Do procesów tych należą: reakcje redox, wytrącanie przez regulację pH, adsorpcja oraz biodegradacja. Reakcje redox z wykorzystaniem żelaza metalicznego Fe0 , jako materiału aktywnego technologii PRB zostały opisane i podzielone na: chemiczną detoksykację węglowodorów halogenowanych oraz wytrącanie kationów metali ciężkich. Na podstawie kolumnowych badań laboratoryjnych oceniono następnie, otrzymane ze składowiska odpadów, żelazo metaliczne, pod kątem możliwości jego wykorzystania do wytrącania z wód gruntowych kationów miedzi Cu2+.
EN
The processes used the most often in PRB technology are presented in the paper. These processes are: redox reactions, precipitation by pH control, adsorption and biodegradation. The redox reactions with the use of iron metal Fe0 as a reactive material in PRB technology were divided into: chemical detoxification of halogenated hydrocarbons and precipitation of heavy metal cations, and described. On the basis of laboratory test the iron metal received from dumping site was assessed later for precipitation of Cu2+ from groundwater.
PL
W artykule omówiono zastosowaną technologię uzdatniania wody podziemnej w zmodernizowanym Zakładzie Uzdatniania Wody w Lubinie.
EN
The article describes the applied technology of groundwaters treatment in the modernized Water Treatment Facility in Lubin.
PL
W pracy scharakteryzowano ujęcia wód podziemnych zaopatrujących Tczew w wodę do picia oraz przedstawiono wyniki badań nad wpływem rodzaju złoża filtracyjnego na skuteczność uzdatniania wód. Porównano efekty uzdatniania wód podziemnych przed i po modernizacji stacji filtrów pospiesznych, w których zastosowano złoża filtracyjne firmy Culligan. Omówiono trudności eksploatacyjne, jakie wystąpiły po uruchomieniu nowych złóż filtracyjnych, ze szczególnym uwzględnieniem jakości bakteriologicznej wody. W badaniach wykazano, że możliwe jest skuteczne uzdatnianie wody podziemnej na odpowiednio wpracowanych złożach piaskowo-antracytowych, które były równie skuteczne jak piroluzytowe złoża katalityczne.
EN
The groundwater intake which serves the needs of municipal water supply for the city of Tczew was characterized. The filter beds were investigated for their contribution to the efficiency of water treatment. The study was carried out before and after the retrofit of the rapid filter station, where the old filter beds were replaced with new ones made by Culligan, and the results were compared. There were operating problems, which appeared following modernization. Special consideration was given to the bacteriological quality of the filtered water. The study has shown that groundwater can be treated efficiently on appropriately adapted sand and anthracite beds, which were found to be as efficient as the pyrolusite catalytic beds.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.