Groundings are necessary parts included in lightning and shock protection. In the case of a surge current, high current phenomena are observed inside the grounding. They are result of the electrical discharges around the electrode when the critical field is exceeded in a soil. An available mathematical model of grounding was used to conduct computer simulations and to evaluate the influence of current peak value on horizontal grounding parameters in two cases. In the first simulations, electrode placed in two different soils were considered. The second case was a test of the influence of current peak value on grounding electrodes of various lengths. Simulation results show that as soil resistivity increases in value, the surge impedance to static resistance ratio decreases. In the case of grounding electrodes lengths, it was confirmed that there is a need to use an operating parameter named effective grounding electrode length, because when it is exceeded, the characteristics of grounding is not significantly improved during conductance of lightning surges. The mathematical model used in the paper was verified in a comparison with laboratory tests conducted by K.S. Stiefanow and with mathematical model described by L. Grcev.
2
Content available remote Własności uziemień przy prądach piorunowych
PL
Przy wymuszeniach prądami udarowymi w uziemieniu zachodzą zjawiska, które znacznie wpływają na wartość jego impedancji. Są to zjawiska falowe związane z szybkimi zmianami prądu i wpływem indukcyjności przewodów uziemienia oraz zjawisko jonizacji w gruncie, związane z przepływem dużych prądów. Wysokoczęstotliwościowe zjawiska falowe powodują wzrost impedancji wejściowej uziemienia natomiast jonizacja w gruncie wpływa na jej zmniejszenie. W artykule przedstawiono analizę właściwości uziemienia kratowego i słupowego przy przepływie prądów piorunowych.
EN
In case of impulse current excitations, phenomena occur in the grounding system that significantly affect the value of its impedance. These are wave phenomena associated with rapid fast current changes, influence of wire inductance and the phenomenon of soil ionization associated with large currents flowing into the ground. High frequency wave phenomena cause the increase of the input ground impedance, while the soil ionization contributes to the decrease of its impedance. The paper presents the analysis of mesh and vertical grounding system properties in case of lightning current flowing.
3
EN
The paper presents the results of preliminary laboratory tests of impulse current distribution in a model of the lightning protection system (LPS). The wooden frame house was prepared in a scale 1:5. It was based on the full size object subjected to lightning currents during open air experiments at the test side in Huta Poręby near Rzeszów. It was equipped with the model of the lightning protection system connected to the supplying electrical installation. The surge current injected to the tested system in the laboratory was produced with use of the lightning transient generator. Measurements were done for three varied shapes of the injected impulse current. The obtained results indicated the frequency dependent behaviour of the tested system. The current distribution in the proposed laboratory model of LPS is similar to those achieved during the tests on the real scale objects in recent years.
PL
drewniany szkielet budynku mieszkalnego, odwzorowujący obiekt używany do poligonowych badań rozpływu prądów udarowych w jego instalacjach piorunochronnej oraz elektrycznej, prowadzonych w Hucie Poręby niedaleko Rzeszowa. Zaproponowany model odzwierciedla istniejącą na poligonie instalację odgromową wraz z przyłączoną do niej niezasiloną typową elektryczną instalacją w postaci wewnętrznej sieci elektrycznej nn wraz z osprzętem, dochodzącej do złącza kablowego ziemnej linii kablowej nn, stacji transformatorowej i linii napowietrznej SN. Pomiarów dokonano dla trzech różnych kształtów wstrzykiwanego prądu udarowego. Uzyskane rozpływy prądów impulsowych są zbliżone do tych, obserwowanych podczas poligonowych badań pełnowymiarowych systemów przez ostatnie lata. Badany model wykazuje zależny od częstotliwości charakter.