Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  grid-tied inverter
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In the finite control set model predictive control (FCS-MPC) strategy of the grid-tied inverter, the current ripple (CR) affects the selection of optimal voltage vectors, which leads to the increase of output current ripples. In order to solve this problem, this paper proposes a CR reduction method based on reference current compensation (RCC) for the FCS-MPC strategy of grid-tied inverters. Firstly, the influence of the CR on optimal voltage vector selection is analyzed. The conventional CR prediction method is improved, which uses inverter output voltage and grid voltage to calculate current ripples based on the space state equation. It makes up for the shortcomings that the conventional CR prediction method cannot predict in some switching states. The improved CR method is more suitable for the FCS-MPC strategy. In addition, the differences between the two cost functions are compared through visual analysis. It is found that the sensitivity of the square cost function to small errors is better than that of the absolute value function. Finally, the predicted CR is used to compensate the reference current. The compensated reference current is substituted into the square cost function to reduce the CR. The experimental results show that the proposed method reduces the CR by 47.3%. The total harmonic distortion (THD) of output current is reduced from 3.86% to 2.96%.
EN
Transformerless inverters are widely used in different photovoltaic nonisolated ac module applications, mainly in grid-tied photovoltaic (PV) generation systems, due to the benefits of achieving high efficiency over a wide load range, and low cost. Various transformerless inverter topologies have been proposed to meet the safety requirement of low ground leakage currents, such as specified in the VDE-4105 standard and low-output ac-current distortion. Topology modifications of transformerless full bridge inverters are designed to balance and maintain a constant common mode output voltage, thereby eliminating or reducing leakage currents. This article reviews and compares the different methods for limiting leakage currents in known topologies of the full-bridge transformerless inverters, such as: H4, H5, H6, HERIC, and their improvements. The main topologies and strategies used to reduce the leakage current in transformerless schemes are summarized, highlighting advantages and disadvantages and establishing points of comparison with similar topologies. To compare the properties of different medium to high power inverters, PV inverter topologies were implemented using IGBTs and tested with the same components, same simulation parameters in PSPICE to evaluate their performance in terms of energy efficiency and leakage current characteristics. The detailed power stage operating principles, extended PWM modulator, and integrated universal gate driver with galvanic isolation in the transmission path of control signal for all IGBTs of the inverter, as well isolated and floating bias power supply for gate drivers are described.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.