Content available remote Control of Voltage Source Inverter with an LCL Filter without Voltage Sensors
EN
The voltage source inverter with LCL filter has to adopt damping method to suppress the resonance of LCL filter, which increases of losses and sensors. With virtual flux estimation idea, grid voltage-sensor-less technology is applied to design observers for the grid voltage, capacitor voltage and current. The observed grid voltage and capacitor voltage is used to realize voltage orientation control and grid current compensation for unit power factor. The observed capacitor current was fed forward to restrain LCL response and keep the control stable. The simulation results verify the correctness of observes design and the control method.
PL
W artykule analizuje się przekształtnik o źródle napięciowym VSI z filtrem LCL w zastosowaniu do sieci elektrowni wiatrowych. Analizę przeprowadza się na podstawie monitorowania napięcia sieci, prądu sieci i napięcia na kondensatorze.