Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  grid side converter
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper is aimed to describe a wind energy conversion system, including a doubly fed induction generator (DFIG), a bidirectional converter in the rotor circuit the DFIG is able to work as a generator in both sub-synchronous and super-synchronous modes. The topology of a DFIG, stator is connected direct to the grid while the rotor is connected to grid with back to back converters. The wind turbine was controlled using a maximum power point tracking with linear PI regulator. The nonlinear backstepping controller is applied to the rotor side converter (RSC) for the independently control of active and reactive powers taking into consideration the full nonlinear model of the DFIG, we don’t neglecting small stator resistor and using voltage oriented control (VOC). The grid side converter (GSC) is controlled by using the oriented voltage control strategy. Also the DC link voltage control ensures the operation of unity power factor by making the reactive power zero. The obtained results are very satisfactory for this new kind of application.
PL
Niniejsza praca ma na celu opisanie systemu konwersji energii wiatru, w sklad którego wchodzi dwustronnie zasilany generator indukcyjny (DFIG), dwukierunkowy przekształtnik w obwodzie wirnika, który DFIG moze pracować jako generator zarówno w trybie podsynchronicznym, ´ jak i nadsynchronicznym. Topologia DFIG, stojan jest podłaczony bezposrednio do sieci, podczas gdy wirnik jest podłączony do sieci za pomocą konwerterów typu back-to-back. Turbina wiatrowa była sterowana za pomocą sledzenia punktu mocy maksymalnej z liniowym regulatorem PI. Nieliniowy ´ regulator krokowy zastosowano w przekształtniku po stronie wirnika (RSC) w celu niezależnego sterowania mocą czynna i bierna, biorąc pod uwagę pełny nieliniowy model DFIG, nie zaniedbując małego rezystora stojana i stosując sterowanie zorientowane na napięcie (VOC) . Konwerter po stronie sieci (GSC) jest sterowany za pomoca zorientowanej strategii sterowania napięciem. Również regulacja napięcia obwodu posredniego zapewnia ´ pracę z jednostkowym współczynnikiem mocy poprzez zerowanie mocy biernej. Uzyskane wyniki są bardzo zadowalające dla tego nowego rodzaju aplikacji.
EN
This paper presents an evolutionary optimization of the linear-quadratic (LQ) current controller for a three-phase grid-tie voltage source converter with an L-type input filter. The current control system is equipped with multi-oscillatory terms, which enable the converter to obtain nearly sinusoidal shape and balanced input currents under unbalanced and distorted grid voltage conditions. The augmentation of the state vector to include additional states which describe dynamics of disturbances increases the number of weights to be selected for a cost function in the LQR procedure design. Therefore, it is proposed that optimal weighting factors are sought using particle-swarm-based method. Finally, the simulational tuning based on the linear model and the numerical verification based on a non-linear model of the system with a pulse width modulator are addressed.
PL
Artykuł prezentuje optymalizację ewolucyjną liniowo-kwadratowego regulatora prądu dla trójfazowego przekształtnika sieciowego z filtrem wejściowym typu L. Układ regulacji prądu jest wypozażony w człony oscylacyjne co pozwala na kształtowanie niemal sinusoidalnych i symetrycznych prądów wejściowych w warunkach występowania wyższych harmonicznych i asymetrii napięć sieci. Rozszerzenie wektora stanu o dodatkowe stany opisujące dynamikę zakłóceń zwiększa liczbę wag, które należy dobrać dla funkcji celu ujętej w procedurze projektowania LQR. Dlatego zaproponowano dobór optymalnych wsółczynników wagowych przy użyciu optymalizacji metodą roju cząstek. Finalnie zostały omówione strojenie symulacyjne na modelu liniowym oraz weryfikacja numeryczna na modelu nieliniowym z modulatorem szerokości impulsów.
EN
The article presents control strategy for the operation of a variable-speed wind energy conversion system with permanent magnet synchronous generator (PMSG). The electrical system of wind turbine consists of PMSG, Switch Mode Rectifier (SMR) and Grid Side Converter (GSC). The SMR converter is composed of an uncontrolled diode bridge and a DC/DC boost converter. In the control of the DC/DC boost converter the algorithm of Maximum Power Point Tracking (MPPT) has been applied. The MPPT algorithm allows the wind turbine to operate at maximum value of power coefficient in a wide range of wind speed. In the control of Grid Side Converter a method of Voltage Oriented Control (VOC) has been applied. High efficiency and accuracy of this control system were confirmed by simulation studies.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.