Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  granular sludge
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Internal Circulation reactor (IC reactor) is an anaerobic digestive system with the capability to treat high-load Chemical Oxygen Demand (COD) of industrial wastewater (e.g. brewery, potato starch, pulp and paper). IC reactor advantages include of the following: only small areas required, shock load resistance, produces more biogas and uses less energy compared to the Upflow Anaerobic Sludge Blanket (UASB) reactor. BIOPAQ@ICX is an upgrade to BIOPAQ@IC that has higher efficiency, lower volume, able to build from the current anaerobic reactor, and its trial has produced positive results in many different countries and with various types of wastewater. A case study of the wastewater treatment plant at Saigon Paper’s mills shows that the IC reactor COD removal rate is over 80% when the COD is not over 2300 mg/L; Volumetric Load Rate (VLR) is 6-14 kgCOD/m3.day and the removal rate is higher with a higher load and could reach 80% at 14 kgCOD/m3.day; granular sludges settle very well, and the three-phase separator is efficient of preventing sludge from washing out; pH, Total Suspended Solids (TSS), alkalinity, Volatile Fatty Acids (VFA), N-NH4+, P-PO4 3- , Ca2+, SO4 2- were also analysed and indicated that the IC reactor is operating well.
PL
Technologia granulowanego osadu tlenowego wydaje się być alternatywnym rozwiązaniem oczyszczania ścieków dla metody klasycznego osadu czynnego. Ze względu na wysokie stężenie biomasy, technologia ta umożliwia przyjęcie większego ładunku czyszczeń bez zmiany kubatury reaktorów biologicznych i, co więcej, daje możliwość efektywnego oczyszczania ścieków w pojedynczym reaktorze [Podedworna i Piechna 2017]. Uzyskuje się szybką sedymentację osadu bez utrudnień w separacji biomasy od ścieków oczyszczonych. Jest to rozwiązanie szczególnie atrakcyjne dla przyzakładowych oczyszczalni przemysłowych borykających się z nierównomiernym składem ścieków oraz dopływem substancji szkodliwych. Dlatego, w ostatnich kilku latach prowadzone są badania nad możliwością granulacji biomasy. Pomimo opisanych wielu doświadczeń, nadal jeszcze nie są poznane wszystkie mechanizmy odpowiedzialne za tworzenie się osadu granulowanego w warunkach tlenowych [Podedworna i Piechna 2017]. Z powodu braku dokładnych wytycznych dotyczących uzyskania i eksploatacji tlenowego osadu granulowanego, ciągle jeszcze nie ma licznych aplikacji w skali technicznej.
3
Content available remote The adjustment of granular sludge DNA isolation for PCR-based methods
EN
European Union regulations require very high standards of wastewater treatment due to both, economic and environmental reasons. Thus wastewater treatment plants are searching for new, efficient technologies to obtain the best quality of WWTPs’ effluent. Among other biological methods granular sludge is known to be effective and useful way for sewage purification due to its better sedimentation properties. Granular sludge is interesting also from microbial ecology point of view. The composition of the granules is very difficult to be analyzed with traditional cultivation methods so molecular tools usage is advisable. In order to perform any molecular analysis DNA isolation is required. In this article we compared two DNA isolation methods – mechanical method and commercial GeneMatrix Soil DNA Isolation Kit (Eurx) and two ways of granular sludge preparation with PBS washing before isolation to check does the method of isolation and preparation influence further laboratory procedures, such as polymerase chain reaction (PCR) amplification and denaturing gradient gel electrophoresis (DGGE) separation and fingerprint obtainment. It was stated that there is no influence of the DNA isolation method on the amount of PCR products obtained, but it influences qualitative DGGE resolution and bioinformatical analysis of the results.
PL
Regulacje Unii Europejskiej zaostrzają standardy dotyczące ścieków oczyszczonych, zarówno z powodów ekonomicznych, jak i ochrony środowiska. Dlatego też oczyszczalnie ścieków poszukują nowych, wydajniejszych technologii oczyszczania ścieków. Wśród tych metod osad granulowany wydaje się być efektywną i użyteczną drogą oczyszczania ścieków, ze względu na lepsze niż tradycyjny osad czynny właściwości sedymentacyjne. Osad granulowany jest interesujący również z punktu widzenia ekologii mikroorganizmów. Analiza składu granul jest niezmiernie trudna do wykonania tradycyjnymi metodami mikrobiologicznymi, dlatego też do takich badań niezbędne jest wykorzystanie metod biologii molekularnej. W celu prowadzenia analiz z zakresu biologii molekularnej konieczne jest izolowanie DNA bakteryjnego. W tej pracy podjęto próbę porównania izolacji DNA dwiema metodami – mechaniczną i z użyciem komercyjnego zestawu odczynników GeneMatrix Soil DNA Isolation Kit (Eurx) oraz wykorzystano dwie modyfikacje przygotowania materiału do izolacji poprzez płukanie buforem PBS. Badania miały na celu określenie, czy procedury przygotowawcze i metoda izolacji mają wpływ na efektywność dalszych procedur badawczych, takich jak amplifikacja z użyciem łańcuchowej reakcji polimerazy (polymerase chain reaction, PCR) oraz rozdział w gradiencie czynnika denaturującego (denaturing gradient gel electrophoresis; DGGE) i uzyskanie wzorów struktury genotypowej zbiorowiska. W badaniach wykazano, że wybór metody izolacji nie ma większego wpływu na ilość uzyskanego produktu PCR, ma jednak wpływ na jakość rozdziału DGGE i wynik analizy bioinformatycznej uzyskanych wyników.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.