Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  glimepiride
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Although glimepiride (GLM) is the first-line treatment of Type II diabetes, low extraction recovery is still a significant limitation in previous plasma analysis methods. An optimized solid-phase extraction method of GLM in human plasma with excellent extraction recovery, 100 ± 0.06%, was achieved using liquid chromatography-electrospray ionization tandem mass spectrometry and Gliclazide (GLZ) as an internal standard. GLM was extracted from 100 µL plasma sample using Sep-Pak® vac 1cc (100 mg) C18 column and methylene chloride: methanol (2: 1, v/v) as eluant. Both GLM and GLZ were monitored by a triple quad mass spectrometer applying positive multiple reaction monitoring mode (+MRM). The protonated precursor ions and product ions of GLM and GLZ were m/z 491(352), and m/z 324 (127), respectively. The detection and measurement of low levels of GLM in human plasma reached to picogram range (limit of detection (LOD) = 60 pg/mL, limit of quantification (LOQ) = 200 pg/mL). The method was validated in terms of selectivity, linearity, recovery, accuracy, and precision. The method was successfully applied to the pharmacokinetic study of GLM following oral administration of 1 mg GLM tablets to 12 healthy volunteers.
EN
An isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) method has been developed for rapid and simultaneous separation and estimation of 3 antidiabetic drugs, namely, metformin, pioglitazone, and glimepiride, in human plasma within 3 min. Separation was carried out on a MAGELLEN 5U C18 (5 μm, 150 mm × 4.60 mm) using a mobile phase of MeOH–0.025 M KH2PO4 adjusted to pH 3.20 using ortho-phosphoric acid (85:15, v/v) at ambient temperature. The flow rate was 1 mL/min, and the maximum absorption was measured at 235 nm. The retention time of metformin, pioglitazone, and glimepiride was noted to be 1.24, 2.32, and 2.77 min, respectively, indicating a very short analysis time compared to that of other reported methods. Also, limits of detection were reported to be 0.05, 0.26, and 0.10 μg/mL for metformin, pioglitazone, and glimepiride, respectively, showing a high degree of method sensitivity. The method was then validated according to the FDA guidelines for the determination of the three drugs clinically in human plasma, in particular, regarding pharmacokinetic and bioequivalence simulation studies.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.