Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 21

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  geoenergetics
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The aim of this study was to adapt the operating parameters of a geothermal heat pump system to the required average power needed to meet the energy for central heating and domestic hot water of selected student residences. Calculations of the average power required by the dormitories in the AGH University Student Campus were carried out, as well as modelling of the deep borehole heat exchanger for the heating load. The designed heating system for the student residences in the AGH University Student Campus using a deep borehole heat exchanger - is sufficient to cover the base heat demand for five four-storey dormitories. During the writing of the paper, the main problem was the low availability of articles on deep borehole heat exchangers. This is due to the continuous development and testing of new engineering ideas. Deep borehole heat exchangers can be use as new boreholes or wells prepared for liquidation. Also use of closed boreholes sometimes is possible, depending on project of liquidation. The future districy heating will use low-temperature heat carrier for heating and cooling. Use borehole fields as rockmass use for heat and/or cool ,storage will be common.
PL
Otworowe wymienniki ciepła to najlepszy sposób na pozyskanie energii zgromadzonej w górotworze niezależnie od litologii. Geotermalne pompy ciepła oparte na cieple niskotemperaturowym mogą być jedną z możliwości redukcji smogu w miastach. W zabytkowych częściach miast często nie ma odpowiednio dużego obszaru do wiercenia otworów. Jest to jeden z wielu powodów poszukiwania konstrukcji otworowych wymienników ciepła o dużej efektywności (jednostkowym transferze ciepła między nośnikiem a górotworem). Jednym ze sposobów na poprawę sprawności jest zastosowanie najbardziej wydajnej konstrukcji otworowego wymiennika ciepła. W artykule opisano badania efektywności cieplnej otworowych wymienników ciepła z wykorzystaniem testów reakcji termicznej. Badaniami objęto otworowe wymienniki ciepła należące do Laboratorium Geoenergetyki AGH oraz dwa testowe otwory o różnych konstrukcjach. Na podstawie interpretacji testów reakcji termicznej oraz wzorów empirycznych obliczono jednostkową wymianę ciepła. Opisano warunki realizacji otworowych wymienników ciepła w zabytkowych miejscowościach, przy małej powierzchni do wykonania wierceń i utrudnionym dostępie do obiektów. Warunki takie wymuszają niewielką liczbę otworowych wymienników ciepła, wobec tego ich większą głębokość, ukośny kierunek wiercenia i/lub specjalną wiertnicę do wiercenia z wnętrz obiektów.
EN
Borehole heat exchangers are the best way to geothermal energy extraction from the ground independent on lithology. Geothermal heat pumps based on the low-temperature heat can be one of possibilities smog reduction in cities. There often is not big area for drilling in the down towns (often with monuments). There is the reason for looking for the constructions of borehole heat exchangers with high efficiency (unit heat transfer between heat carrier and ground). One of the ways to improve the efficiency is use the most efficient construction of borehole heat exchanger. In the paper is described a research of thermal efficiency of borehole heat exchangers with use thermal response tests. The Laboratory of Geoenergetics borehole heat exchangers was studied. Based on thermal response tests interpretation and on empirical formulas unit heat transfer was calculated. Other conditions for use borehole heat exchangers in down towns was discussed. The conditions with small area and with difficult access to the field of drilling forces small number of borehole heat exchangers; its higher depth; directional axis, special rig for drilling.
PL
Dynamiczny rozwój systemów pozyskiwania energii odnawialnej, a także racjonalizacja gospodarki cieplnej, przyczyniły się 10 lat temu do budowy Laboratorium Geoenergetyki na Wydziale Wiertnictwa, Nafty i Gazu AGH w Krakowie. Jednym z ważnych czynników decydujących o budowie są wcześniejsze prace nad wykorzystaniem wyeksploatowanych i negatywnych otworów do celów geotermalnych. Prowadzone aktualnie w Laboratorium badania dzisiaj i jego funkcje zostały opisane w niniejszym artykule. Laboratorium bazuje na różnych typach otworowych wymienników ciepła. Zostały one zbadane pod kątem ich efektywnej przewodności cieplnej λef i odporności termicznej Rb. Przeprowadzone w nich testy reakcji termicznej wykorzystano do opracowania metodyki i weryfikacji testów przewodnictwa cieplnego wymienników otworowych. Wyniki takiego testu mogą być stosowane do optymalizacji struktury i technologii eksploatacji dużych podziemnych magazynów ciepła bazujących na otworowych wymiennikach ciepła. System wymienników otworowych może współpracować z różnymi typami kolektorów słonecznych, które w odpowiedniej strefie klimatycznej mogą być idealnym źródłem do regeneracji zasobów podziemnego magazynu ciepła.
EN
The dynamic development of renewable energy recovery systems and also the rationalization of heat management gave spur to the 10 year construction agh of the Geoenergetics Laboratory at the Drilling, Oil and Gas Faculty AGH University of Science and Technology (DOGF AGH-UST) in Krakow. One of the important factors deciding about the build are previous works on adapting depleted and negative wells. Research carried out at the Laboratory up today and its usability functions are described in the paper. The laboratory is based on various types of borehole heat exchangers. They were investigated in view of their design for their effective thermal conductivity λef and thermal resistance Rb. The thermal response tests were used for elaborating the BHE thermal conductivity test. It can be used for optimizing the structure and technology of the exploitation of large underground heat storages with borehole heat exchangers. This system can co-operate with various types of solar collectors which in an appropriate climate zone may be a perfect source to be used for charging underground heat storage.
EN
The Geoenergetics Laboratory at the Faculty of Drilling, Oil and Gas in Krakow is presented in this paper to mark its 10th anniversary. The origins of the Laboratory, its equipment and the design of borehole heat exchangers belonging to the field research station are also discussed. Recently, the construction of 14 new borehole heat exchangers was designed and the boreholes will be drilled in the area of AGH University. They will perform heating and cooling for the new S1 building of the University. Every borehole heat exchanger will be tested, with the effective thermal conductivity and borehole thermal resistivity calculated after a thermal response test on every borehole. The difference between boreholes should show the difference of borehole thermal resistivity, but the effective thermal conductivity should be the same.
EN
For the correct design, the number and the location of borehole heat exchangers, it is necessary to know thermal properties of rocks and the exchanger. This applies particularly to larger installations, more than 100 kW. One of the methods of determining these values is Thermal Response Test. This method is based on measurements in the first drilled borehole heat exchanger. Based on results of the TRT geothermal analysis is made. The analysis defines: the number of wells, the arrangement of wells, and the parameters of temperature of heat carrier after long-term use. This analysis based on calculations using specialist software. This paper presents the determination of the number of borehole heat exchangers and working conditions (temperature of the heat carrier) of an underground heat reservoir accessed using borehole heat exchangers for the building of the Primary School in Myszków.
EN
Sometimes there is not enough room for drilling vertical borehole heat exchangers. Hence, the idea of slant boreholes emerged. They can provide access to a rock mass, being an underground heat reservoir, located beneath infrastructure. To optimize the average value of thermal conductivity and use those layers in a given geological profile that possess best properties in the view of thermal efficiency, Geothermal Radial Drilling is used, being a very efficient technology. A GeoDrill 4R drill rig, specially designed for the Geothermal Radial Drilling technology, enables drilling at an angle between 30 and 65 degrees, which in turn, together with data on the geological profile, allows for designing the layout of exchangers so as to obtain longest possible section of a given exchanger within most energetic layers. The paper includes a description of a few investments which use Geothermal Radial Drilling for heating purposes. It also presents a comparative study between Geothermal Radial Drilling and conventional vertical borehole exchangers.
EN
Projects involving borehole heat exchangers more often need to undergo a series of tests before implementation. Inserted pipes and cement in the borehole may have diff erent thermal properties. Until recently, such values were determined in approximate, based on values taken from the literature. Special methods are used more often to perform this type of work in order to correctly determine the properties of a borehole heat exchanger. The aim of the study was to present an analysis of thermal properties of borehole heat exchangers with the main emphasis on parameters such as thermal conductivity and thermal resistance. The analyzed data was obtained through the use of three methods:– analysis of the lithological profi le with rock conductivity based on the literature,– analysis of natural temperature profi le in aborehole heat exchanger (logger NIMO-T),– thermal response test.
EN
The mountain areas, due to their specificity, require special approach to issues concerning heating and air-conditioning of buildings. After presenting general information on demand for heat in a standard residential building, the forecasting of demand for final energy by particular branches of economy has been presented. Fossil fuels are most commonly used in heating buildings. In this kind of systems the heat is supplied to the consumer by means of heating pipes provided by heat power stations or combined heat and power stations or it is generated in boilers owned by the consumers. The remote heat source can also be energy from geothermal power station, as it is in the Podhale region. There is an alternative solution to these systems in the form of heat pumps that are often connected to borehole heat exchangers. Depending on the energy balance of the heating system and air-conditioning of a particular building the latter system can be additionally aided by solar collectors. This method requires only a power service connection, which is available almost in every building. Moreover, practical uses of the proposed system, which should be more widely applied in the mountain areas, have been described.
9
Content available remote The analysis of long-term borehole heat exchanger system exploitation
EN
The key issue in designing borehole heat exchangers (BHE) is the long-term performance of the ground source heat pump (GSHP) systems. The performance directly reflects economic profitability and depends on a large number of parameters including rock formation, the construction of the borehole heat exchangers, working parameters (circulation rates) and thermal load. The objective of the paper is to perform a realistic long-term (up to 10 years) analysis of the ground system to show possible degradation of efficiency over time. A mathematical model of the heat transfer in a borehole heat exchanger and the surrounding area has been constructed for parameters of the currently running experimental system. The long-term performance of the ground source heat pump system is evaluated.
EN
The regeneration of rock mass heat resources with the use of four sources can be done with the use of installations owned by the Geoenergetics Laboratory, Faculty of Drilling, Oil and Gas AGH UST. This paper is devoted to one of them, i.e. an air heater. In the case of increased thermal energy consumption the rock mass can be excessively cooled, which may cause problems with providing thermal standard for buildings making use of ground as a source of heat. New additional sources supplementing the process of heat resources regeneration is a key element of maintaining the high efficiency of the heating-cooling system. A real case exemplifying how free thermal energy can be stored with an air heater in the summer season is discussed in this paper. The procedure and respective conclusions are analyzed. The results of most important measurements are tabularized and their functions plotted in the form graphs.
EN
Reynolds number defines the fluid flow character. Three types of flow are distinguished: laminar, transitional and turbulent flows. By changing the flow conditions in the coaxial vertical borehole heat exchanger, a research was carried on energy (heat) exchange. The authors analyzed the flow of fluids through a model of concentric vertical heat exchanger in the Laboratory of Geoenergetics in AGH University of Science and Technology, Faculty of Drilling, Oil and Gas. Measurements for different materials and dimensions of internal column were performed.
PL
W artykule opisano metodę wykonywania ukośnych wierceń dla instalacji rur otworowych wymienników ciepła. Z wykorzystaniem przewodu giętkiego i silnika wgłębnego możliwe jest wykonywanie otworów o osi pod dowolnym kątem w stosunku do pionu. Dzięki temu możliwe jest udostępnienie górotworu jako rezerwuaru ciepła pod obiektami infrastruktury miejskiej.
EN
There are the slant drilling method for borehole heat exchangers described in the paper. Using coiled tubing and mud motor there is possible drilling the wells at any angle from the vertical. This allows you to access the rock mass as a heat reservoir at the facilities of urban infrastructure.
EN
In the article, there has been described research conducted in underground thermal energy storage (UTES). There have been also presented temperature measurements led in thermo-piezometric boreholes. On the basis of the measurements, the correctness assessment of borehole heat exchangers (BHE) arrangement has been accomplished.
EN
This work reviews possibility of using the heat from impermeable hot dry rock formations. Significant development in hydraulic fracturing technique in a last few years have a result in making accessible sources of energy from impermeable rocks, including hot dry rocks, which wasn't possible before. This paper presents the idea of utilization the EGS system which is based on forced and closed water circulation in a natural and permeable geological reservoir or in a reservoir, where the fractured zone was created artificially by for example hydraulic fracturing treatment. The article shows also an examples of recent EGS/HDR systems around the world.
PL
Badania świeżych zaczynów cementowych obejmowały dostępne na polskim rynku mieszanki do cementowania otworowych wymienników ciepła. Badania przeprowadzone w Laboratorium Płynów Wiertniczych na Wydziale Wiertnictwa, Nafty i Gazu AGH w Krakowie, wykonano na takich produktach jak: ThermoCem Plus, Hekoterm, Stuwa Therm 2000. Przygotowano różne receptury tych produktów oraz testowano ich gęstość, rozlewność, lepkość umowną, pH filtratu, filtrację rzeczywistą (właściwą), odstój oraz właściwości reologiczne takie jak lepkość pozorna, lepkość plastyczna i granica płynięcia. Najlepsze wyniki uzyskano dla ThermoCem Plus. Dwie pozostałe mieszanki, które najprawdopodobniej bazują na piasku kwarcytowym, cechowały się słabą przetłaczalnością. Za pomocą numerycznego programu komputerowego Rheo Solution dobrano optymalny model reologiczny dla ThermoCemu Plus, gdyż tylko ten zaczyn spełniał kryteria zaczynu cementu wiertniczego. Program dopasował do badanego zaczynu model Herschleya-Bulkleya.
EN
Research on fresh cement slurries, included mixtures available on Polish market. Tests made in laboratory of Drilling Fluids on Drilling, Oil and Gas Faculty AGH in Cracow. Cement slurries which were testing were: ThermoCem Plus, Hekoterm and Sffiwa Therm 2000. Various recipes were prepared. Focused on the testing density, fluidity, pH of the filtrate, conventional viscosity, effective filtration, sedimentation and rheological properties. ThermoCem Plus best met all the parameters. The other products, which probably based on quartz sand, were characterized by pour flow properties. Only ThermoCem could be classified as drilling cement. Special computer program - Rheo Solution was used for choose the best rheological model. The best model was Herschley-Bulkley's model.
16
Content available Wiercenia udarowo-obrotowe w geoenergetyce
PL
Wiercenia udarowo-obrotowe stosowane są od dawna. Obecnie przeżywają swój renesans dzięki technologii dolnego młotka DTH (down the hole). Wiercenia takie na dużą skalę stosuje się do wykonywania otworowych wymienników ciepła, szczególnie w skałach twardych. W dużych instalacjach podziemnych magazynów ciepła konieczne bywa wywiercenie dziesiątek, a nawet setek otworów. Dążono zatem do opracowania techniki szybkiego urabiania skał z zachowaniem pionowości otworów. Do tego celu zaadoptowana została technika wiercenia udarowo-obrotowego (DTH).
EN
Hammer-rotary drilling have long been known. Currently experiencing its second youth thanks to technology DTH (down the hole). Drilling such a large scale is used to perform borehole heat exchangers, especially in hard rocks. In large installations, underground thermal energy storages is sometimes necessary to drill tens and even hundreds of boreholes. Was needed so quickly quarrying technique while maintaining the vertical holes. For this purpose, has been adapted down the hole drilling.
PL
Zastosowanie systemu grzewczo-klimatyzującego opartego na pompach ciepła wymaga wykonania instalacji pobierającej energię z niskotemperaturowego źródła i przekazującą ją do parowników pomp ciepła. Racjonalizacja gospodarowania energią bazującą na górotworze jako rezerwuarze ciepła umożliwia grzanie i chłodzenie w zależności od potrzeb. W artykule opisano instalację grzewczo-klimatyzacyjną, której działanie opiera się na pompach ciepła oraz zespole wymienników otworowych dostarczających energię niskotemperaturową używaną do aktywnego ogrzewania oraz aktywnego i pasywnego klimatyzowania zespołu hotelowego.
EN
Heating-air conditioning system need the installation, which exploit low-temperature energy and transport it to the condensers of heat pumps. Improvement of energy manage based on rockmass as heat reservoir give possibility heating and cooling dependence on needs. There is describe on the paper heating-cooling installation, which operation lean against heat pumps and borehole heat exchangers (BHE) units. BHE deliver low-temperature energy used for active heating, active cooling and direct cooling hotel complex.
PL
W artykule podano historię powstawania oraz stan aktualny Laboratorium Geoenergetyki. Opisano istotę pracy, możliwości badawcze a także funkcje utylitarną polegającą na ogrzewaniu i klimatyzacji sali audytoryjnej Wydziału Wiertnictwa, Nafty i Gazu Akademii Górniczo-Hutniczej im. Stanisława Staszica w Krakowie.
EN
In the paper have been described history of build the Laboratory of Geothermics and it actually condition. There are characterise research possibility and also utility as heat and cold source for Drilling, Oil and Gas auditorium in AGH University of Science and Technology.
PL
Wykonywanie układów grzewczo-chłodniczych opartych na pompach ciepła i wymiennikach otworowych staje się w Polsce coraz bardziej popularne. Wiele otworów wierconych jest na potrzeby separowanych instalacji na osiedlach domów jednorodzinnych lub bloków mieszkalnych. Największą w Polsce pojedynczą instalacją obsługiwaną przez zestaw rur w górotworze jest wykonany w 2009 roku system dla marketu IKEA w Łodzi. Składa się z 160 otworów wiertniczych o głębokości 100 m każdy, które wraz z górotworem tworzą rezerwuar ciepła i chłodu. Ciepło pobierane zimą z górotworu powoduje jego wychłodzenie, tworząc magazyn chłodu na lato, kiedy funkcjonuje klimatyzacja. Dostarczanie chłodu do instalacji odbiorczej latem jest procesem wprowadzania do górotworu ciepła, które jest wykorzystywane zimą do celów grzewczych. Liczba otworowych wymienników ciepła zależy od wymaganej mocy wymiany ciepła pomiędzy górotworem a instalacją odbiorczą oraz od właściwości otworowych wymienników ciepła i skał udostępnionych do wymieniania ciepła. Do określenia wymaganej liczby wymienników otworowych niezbędna jest znajomość efektywnej przewodności cieplnej profilu Lambda/ef, rezystancji termicznej otworu Rb oraz naturalnej średniorocznej temperatury statycznej udostępnionego górotworu Tsr. Aby te parametry poznać, konieczne jest wykonanie przynajmniej jednego wymiennika otworowego i przeprowadzenie w nim testu reakcji termicznej (TRT).
EN
The heating/cooling systems based on borehole heat exchangers become increasingly popular in Poland. A number of boreholes are drilled for separate installations in estates of detached houses or blocks of flats. The biggest such single installation in Poland supplied by a set of pipes in the rock mass was made for IKEA in Łódź in 2009. It has been based on 160 boreholes 100 m deep each, forming a heat/cold reservoir. Heat taken from the rock mass in winter cools the reservoir, thus forming a reservoir of cold for the summer months. Providing cold to the receiving installation in summer lies in introducing heat to the rock mass to be later used for heating purposes in the winter season. The number of borehole heat exchangers depends on the required heat exchange power between the rock mass and the receiving installation, as well as the properties of the borehole heat exchangers and the rock mass involved. For determining the needed number of borehole heat exchangers it is necessary to know the efficiency of heat conductance of the profile Lambda/ef, thermal resistance of the borehole Rb and natural average annual static temperature of the rock mass involved Tsr. These parameters can be established after a heat exchanger is performed and thermal reaction test (TRT) carried out in it.
PL
W publikacji opisano realizacje otworowych wymienników ciepła na świecie i w Polsce. Zaprezentowano podstawowe konstrukcje wymienników otworowych. Przedstawiono możliwości wymiany ciepła. Podano obliczenia przewodności cieplnej efektywnej wymienników otworowych Laboratorium Geoenergetyki WWNiG AGH w Krakowie, a także wartości oporności termicznej wymienników, które mają wpływ na efektywność energetyczną.
EN
There are described in the paper drilling of borehole heat exchangers (BHE) on the world and in Poland. The most popular constructions of BHE are described with possibility of heat extraction. There are also showed results of calculation of effective heat transfer coefficient of the Laboratory of Geoenergetics of Drilling, Oil and Gas Faculty of AGH University of Science and Technology BHEs with its heat resistivity. This parameters decided for energetic efficiency of the BHEs.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.