Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  generator wiatrowy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A quick post fault recovery of wind generator system could be achieved with the help of a series dynamic braking resistor (SDBR). This paper investigates the dynamics, size, optimal location of a series dynamic braking resistor in the Doubly Fed Induction Generator (DFIG) structure based on different switching strategy of the braking resistor. Three signals were investigated in switching the SDBR during transient conditions of the DFIG wind generator; the DC-link voltage, rotor current and grid voltage respectively. Also, three locations were considered in connecting the SDBR in the DFIG system; the stator, rotor and grid side converter respectively. Furthermore, the optimum size and best insertion time of the SDBR were investigated based on the most effective performance of the SDBR scheme considering its switching signal and position in the DFIG system. Simulations were run in Power System Computer Aided Design and Electromagnetic Transient Including DC (PSCAD/EMTDC). The results show that when the SDBR is connected to the DFIG, improved performance was achieved, however, the stator based SDBR topology in conjunction with a grid voltage actuating signal, fast insertion time and short duration of operation, quickly recovered the DFIG wind generator variables during transient conditions.
2
Content available remote Analiza możliwości rozbudowy instalacji fotowoltaicznej o turbinę wiatrową
PL
W artykule omówiono możliwość rozbudowy przydomowej instalacji fotowoltaicznej o mały generator wiatrowy. Przedstawiono obliczenia mocy generowanej zależnie od rozmiarów wirnika turbiny. Obliczenia energii wyprodukowanej przez generator wykonano dla wybranej lokalizacji o stosunkowo słabych warunkach wietrznych. Wyznaczono przykładowe rozkłady dobowe mocy: generowanej przez generator wiatrowy, panele fotowoltaiczne oraz całkowitej oddawanej przez falownik do sieci energetycznej.
EN
The article discusses the possibility of expanding a home photovoltaic installation with a small wind turbine. Calculations of the dependence of the generated power on the size of the turbine rotor are presented. The calculations of the energy produced by the generator were made for a selected location with relatively weak wind conditions. Examples of daily distributions of the power generated by the wind turbine, photovoltaic panels and the total power transferred by the inverter to the power grid were determined.
EN
This paper presents the results of a survey on the application of simple and multiple linear regression in wind power generation research. Relevant publications were searched for, found, reviewed, and summarised. An increasing trend of number of publications on this topic was found. The main categories of publications forecasting of wind output power, forecasting of wind speed, and wind turbine generator temperature monitoring. The paper presents coincise summaries of publications and details the references identified, all of this in one repository.
PL
W artykule przedstawiono wyniki badań ankietowych dotyczących zastosowania prostej i wielokrotnej regresji liniowej w badaniach energetyki wiatrowej. Odpowiednie publikacje zostały wyszukane, znalezione, zrecenzowane i podsumowane. Stwierdzono rosnący trend liczby publikacji na ten temat. Główne kategorie publikacji: prognozowanie mocy wiatru, prognozowanie prędkości wiatru oraz monitorowanie temperatury generatorów turbin wiatrowych. W pracy przedstawiono zwięzłe streszczenia publikacji i wyszczególnienie zidentyfikowanych pozycji literaturowych, a wszystko to w jednym repozytorium.
EN
The work proposes the structure of a diagnostic system, which is used to ensure the functioning of autonomous measuring transducers placed on the diagnosed parts of wind turbine generators (WT). For this purpose, the Energy Harvesting (EN) technology was used, which is designed to provide power to electronic devices in autonomous vibration measurement systems. Energy Harvesting technology converts the mechanical energy of vibrations into electrical current.
EN
In the article the prediction of wind speed values by Newton interpolation polynomials is made. It is mentioned that effective operation of the wind power station is realized by predictive control on the basic interval according to the predictor–corrector method. Equations for Newton interpolation polynomials are given. The fluctuations of the wind speed deviations occur random so can be described with Wiener process. An ex ample of wind speed deviations, described with Wiener process, is shown. Equation to estimate the prediction error is given. The results of wind speed values prediction taking into ac-count the Wiener process that simulates its fluctuations are shown. The wind speed prediction for 1 hour in advance without taking into account the Wiener process is shown depending on the degree of the interpolation polynomial. The prediction errors at different degrees of the interpolation polynomials and the prediction for different number of hours in advance are given. It is noted that with the removal of a random component in the form of Wiener process, the average error of the prediction decreases.
PL
W artykule dokonano symulacji wartości prędkości wiatru na podstawie wielomianów interpolacyjnych Newtona. Wspomniano, że efektywna praca elektrowni wiatrowej realizowana jest poprzez kontrolę predykcyjną w podstawowym przedziale zgodnie z metodą predykcyjno-korektorową. Podano równania dla wielomianów interpolacyjnych Newtona. Fluktuacje odchyleń prędkości wiatru występują losowo, dlatego można je opisać w procesie Wienera. Pokazano przykład odchyleń prędkości wiatru, opisany w procesie Wienera. Podano równanie do oszacowania błędu prognozowania. Pokazano wyniki symulacji prędkości wiatru z uwzględnieniem procesu Wienera, który symuluje jego fluktuacje. Prognozę prędkości wiatru z 1-godzinnym wyprzedzeniem bez uwzględnienia procesu Wienera pokazano w zależności od stopnia wielomianu interpolacji. Podano błędy prognozowania dla różnych stopni wielomianów interpolacyjnych i przewidywania dla różnej liczby godzin wcześniej. Należy zauważyć, że wraz z usunięciem elementu losowego w postaci procesu Wienera zmniejsza się średni błąd prognozy.
PL
Dzięki coraz powszechniejszemu zastosowaniu systemów zasilania energią odnawialną z zastosowaniem generatorów fotowoltaicznych (PV) i turbin wiatrowych (TW) jest możliwość zaimplementowania tych układów do zasilania w sposób autonomiczny budynków mieszkalnych. Bardzo istotnym czynnikiem wpływającym na efektywność wielosystemowych układów zasilana jest odpowiednie zbilansowanie całego systemu. W artykule opisane zostały analizy dokonane na podstawie rzeczywistych danych pomiarowych wykonywanych w funkcjonującym budynku mieszkalnym z zastosowaniem współpracujących układów turbin wiatrowych, paneli fotowoltaicznych, generatora na biopaliwo oraz magazynu wyprodukowanej energii elektrycznej.
EN
With the increasingly widespread use of renewable energy power supply system using photovoltaic generators (PV) and wind turbines (WT) it is possible to implement these systems to autonomous power supply of the residential buildings. A very important factor influencing the effectiveness of multi-system systems is the proper balance of the whole system. This article describes the analysis made on the basis of actual measurement data in a functioning residential building using co-operating wind turbine systems, photovoltaic panels, biofuel generator and the storage of produced electricity.
7
Content available remote Single-Phase PFC for Three-Phase Wind Generator, a Modular Approach
EN
To adapt a 3-phase wind alternator to a variable DC-bus, a modular solution based on single-phase Boost-based PFC’s is proposed. Nevertheless, oost modules must be adapted to operate with non-isolated sources, like 3-4 wire, 3-phase generators. Magnetic coupling is introduced to enhance the isolation among phases, reducing also converter losses and size. Sliding mode approach has been applied to verify that independent regulation of all phase modules was possible. To confirm the theoretical analysis A 1.5 kW prototype was built for verification.
PL
W artykule zaproponowano układ modułowy do sprzęgania generatora wiatrowego z regulowanym obwodem prądu stałego oparty na jednofazowym układzie korekcji współczynnika mocy typu boost PFC. Układ boost został zaadoptowany do pracy ze źródłami nieizolowanymi takimi jak trzy- i czteroprzewodowe generatory trójfazowe. Zaprezentowano sprzężenie magnetyczne poprawiające izolację międzyfazową redukującą także straty w przekształtniku oraz jego wymiary. Zastosowano sterowanie ślizgowe w celu wykazania możliwości niezależnego sterowania we wszystkich fazach. Zbudowano prototyp o mocy 1,5 kW do weryfikacji eksperymentalnej wyników analiz teoretycznych.
CS
Pfispevek shrnuje zkuśenosti autora s posuzovanim vlivu vetrnych elektraren na zivotni prostfedi. V uvodni ćasti pfispevku jsou uvedeny legislativni povirmosti Ćeske republiky pri plneni limitu Evropske unie v oblasti vyuzivani alternativnich zdroju energie. Dalsi cast je venovana analyze vlivu vetrnych elektraren na zivotni prostfedi. Zaver pfispevku je venovan zkusenostem s implementaci procesu posuzovani vlivu na zivotni prostfedi v oblasti vetrne energetiky v Ćeske republice.
EN
The article summarizes author's experience with environmental impact assessment in branch of wind generators. The introductory part of paper describes legislative obligations of the Czech Republic in frame of fulfilling the European Union's limits in branch of renewable energy resources utilization. Next part of paper deals with analysis of impacts of wind generators on the environment. The final part of paper deals with experience with implementation of the environmental impact assessment process (pursuant to the Act No. 100/2001 Coll.) in the field of wind power in the Czech Republic.
10
Content available remote Elektrownia wiatrowa Kamieńsk na tle innych elektrowni wiatrowych
PL
Przedstawiono charakterystykę farmy wiatrowej Kamieńsk w zakresie parametrów wiatru, fundamentowania wież oraz bezprzekładniowych turbozespołów E70-E4 firmy ENERCON, które zostały zainstalowane w elektrowni. Omówiono specyfikę zastosowanych rozwiązań w odniesieniu do innych krajowych elektrowni wiatrowych.
EN
The characteristic of Kamieńsk wind farm concerning wind parameters, towers foundation and E70-E4 ENERCON direct-drive synchronous generators installed in power plant was shown. The specificity of used solutions compared to other wind domestic power plants was discussed.
PL
Niniejsza praca służy ocenie dynamicznych aspektów pracy generatora wiatrowego w obecności zwarć w punkcie przyłączeniowym sieci, z uwzględnieniem warunków wiatrowych. Przeprowadzone analizy ukierunkowane zostały na przedstawienie charakteru wahań mocy, towarzyszących pracy jednostek wiatrowych w warunkach dynamicznych. W celu kompleksowej oceny badanego zjawiska zaproponowano metodę połączonej reprezentacji w czasie i częstotliwości.
EN
This work is dedicated to dynamic aspect of wind turbine work under fault conditions at point of common coupling with respect to wind conditions. The aim of the investigations is to uncover distortion of generated power. In order to achieve complex character of investigated phenomena joint time-frequency analysis was applied.
EN
The paper describes small yacht's wind power-stations (also called wind-mills) designed and made by Komel Centre (Katowice, Poland). After marine tests of the first windmill (diameter 1 m) the second, smaller one (diameter 0,75 m) was designed and manufactured. The windmill having nominal output 120 W at wind 12 m/s is intended to be installed on yachts of size up to 15 m. The paper shows results of exploitation tests of the wind power-station, also during very strong wind (up to 22 m/s). In both wind mills permanent magnet alternator designed and manufactured by Komel were used. The alternators having very high efficiency do not have any brushless and can be used in hard working conditions in marine duty.
13
Content available remote A laboratory system for comprehensive investigation of wind generators
EN
This paper focuses on developing and testing a comprehensive monitoring and detection laboratory system, suitably adapted for use in wind generator systems using Doubly Fed Induction Generators (DFIG). The article aims to provide wind generators with further documentation for an advanced condition monitoring system including transducers, signal conditioning box and data acquisition device, in order to avoid undesirable operating conditions and to detect and diagnose incipient electricai faults. Also, this paper suggests the possibility of diagnosing different types of failures by means of spectral analysis of current and voltage.
PL
Artykuł opisuje system laboratoryjny przeznaczony do badania generatorów wiatrowych wykorzystujących Podwójnie Zasilane Generatory Indukcyjne (Doubly Fed Induction Generators - DFIG}. Artykuł opisuje możliwości wyposażenie generatorów w system monitorowania warunków pracy - uwzględniając także bloki przetworników, obwodów kondycjonowania sygnałów i zbierania danych. Taki system powinien umożliwiać unikanie niepożądanych warunków pracy oraz diagnozowanie możliwych uszkodzeń. Opisano także możliwość diagnozowania uszkodzeń na podstawie analizy spektralnej prądu i napięcia.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.