Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  generator pary
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Modelling and an adaptive fuzzy logic controller of solar thermal power plant
EN
This article aims to model and control a solar thermal power plant. The modeling and the dynamic behavior of the system have been well studied and carried out the variation of the exchanger temperature by acting on different parameters, such as the length, the exchange surface, and the exchange coefficient. A comparison was made between conventional PI control and an advanced AFLC-PI fuzzy logic-based control to drive the steam turbine. This advanced command improves the system's robustness with respect to internal disturbances (parametric variations) and external disturbances (sudden pressure variations).
PL
Celem artykułu jest modelowanie i sterowanie elektrownią słoneczną. Modelowanie i dynamiczne zachowanie systemu zostały dobrze zbadane i przeprowadzono zmianę temperatury wymiennika poprzez oddziaływanie na różne parametry, takie jak długość, powierzchnia wymiany i współczynnik wymiany. Dokonano porównania między konwencjonalnym sterowaniem PI a zaawansowanym sterowaniem opartym na logice rozmytej AFLC-PI do napędzania turbiny parowej. To zaawansowane polecenie poprawia odporność systemu na zakłócenia wewnętrzne (zmiany parametryczne) i zewnętrzne (nagłe zmiany ciśnienia).
EN
The article presents a model of a steam generator based on mass and energy balance equations, heat transfer coefficients, criterion relations and Peclet’s law. The presented model was applied to a steam generator without and with an economizer for a PWR/EPR nuclear power plant. Based on the calculations, the steam pressure at the outlet of the steam generator without the economizer is 74.17 bar, and for the model with the economizer it is 77.2 bar. The pressure difference for these two variants, based on the calculations, was therefore 3 bar. Higher steam pressure at the outlet of the steam generator translates into a greater enthalpy drop in the turbine and greater power generated by the steam turbine and the efficiency of the entire nuclear power plant. Based on the economic calculations carried out for 60 years of operation of a nuclear power plant with four steam generators, the profit from the use of the economizer amounted to about PLN 0.6 billion.
3
Content available remote Metody generacji kontrolowanych stężeń par sarinu
PL
Przedstawiono metody generowania par sarinu, które opracowano i przebadano w Wojskowym Instytucie Chemii i Radiometrii (WIChiR). Porównano trzy metody generacji par sarinu: z zastosowaniem kapilary, metalowego naczynia generacyjnego oraz z wykorzystaniem roztworów sarinu w odpowiednich rozpuszczalnikach alifatycznych. Stężenia próbek gazowych były analizowane z wykorzystaniem GC-FPD. Dokonano analizy każdej z metod pod kątem stabilności generacji par sarinu.
EN
Three potentially stable methods of generating sarin vapour were compared using (i) a capillary, (ii) solns. of sarin in suitable aliphatic solvents and (iii) a metal vessel and liquid sarin. The gas sample concns. were analyzed using the GC-FPD. The best results were obtained for the method (iii), which showed high repeatability and stability of the generated sarin concn. over time and was characterized by increased work safety.
PL
Zastosowanie nowoczesnych, wielokanałowych systemów chemicznego i fotochemicznego generowania par umożliwia selektywne wydzielanie wielu pierwiastków z próbki analitycznej i efektywne ich wprowadzanie, wraz z aerozolem, do źródeł atomizacji/wzbudzenia/jonizacji.
EN
Since the development of the first oil fields on the Norwegian Continental Shelf, the petroleum industry in Norway has been making continuous progress in oil production engineering. With greater environmental awareness and increasing taxation of NOx and CO2 emissions, the economic pressure has been rising in recent decades. The energy demand for o shore oil and gas production is high. With a view to improving power generation on offshore oil and gas installations, four models of dierent power cycles were investigated: a simple cycle gas turbine (currently the default option), a compact combined cycle with enhanced fuel utilization, a steam injection gas turbine cycle as an innovative solution, and a state of the art combined cycle for onshore applications as a reference cycle. Special requirements for o shore installations are discussed and sizing was identified as the major criterion. The power demand of an oil platform and its change during dierent states in field life were analyzed. To complete the simulations, the models were set to off-design conditions and the part-load behavior was investigated. The plant layouts were laid out and visualized with 3D CAD models.
EN
The prediction of radiation doses obtained during dismantling of steam generator represents one of the most crucial issues within the process of decommissioning of nuclear installations. Given the fact that in Slovakia the nuclear power plant VI in Jaslovské Bohunice is currently being decommissioned, represents the analysis of the segmentation of steam generator an actual issue. In this paper, the proposed dismantling methodology together with the results of calculations is given. Also the complex analysis of the influence of different distance of workers carrying out the dismantling as well as the influence of the time on the total collective effective dose is carried out. The results of this analysis show that the obtained doses are below the legislative limits and thus the main consequences can be applied in the process of VI nuclear power plant decommissioning.
PL
Przewidywanie dawek promieniowania na które narażona jest obsługa w trakcie demontażu generatora pary reprezentuje jedną z najbardziej kluczowych problemów w ramach procesu likwidacji obiektów jądrowych. Mając na względzie fakt, że na Słowacji elektrownia jądrowa VI w Jaslovské Bohunice jest obecnie wycofywana z ruchu, analiza segmentacji generatora pary stanowi aktualny problem. W pracy zaproponowano metodologię demontażu i podano rezultaty obliczeń. Także złożona analiza wpływu różnych odległości pracowników przeprowadzających demontaż jak również wpływ czasu na całkowitą efektywną zespołową dawkę promieniowania jest przeprowadzony. Wyniki tej analizy pokazują że przyjęte dawki są poniżej limitów wyznaczonych normami i zatem główne konsekwencje mogą być stosowane w procesie demontażu jądrowej elektrowni VI.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.