Luminous flux reduction during operation affects the operating lifetimes of LED lamps. Due to the very long lifetimes of LED sources, i.e. tens of thousands of hours, the lifetime declared by the manufacturer is most often determined by forecasting the luminous flux reduction. Lifetime forecasting is performed based on measuring the operating luminous flux reduction within a time frame of at least 6000 hours, every 1000 hours, followed by extrapolating the obtained results with a relevant exponential curve. This article presents the results of measurements of luminous flux changes taking place between 0 and 10,000 operating hours of several LED light sources. The obtained results were analyzed, and the lifetimes of the examined lamps were evaluated.