Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  fluktuacja prędkości
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this work, a numerical study of a sharply expanding highly swirling flow is carried out using v2-f models based on the Comsol Multiphysics 5.6 software package and a two-fluid turbulence model. The results obtained are compared with known experimental data with different pipe diameters. The purpose of this work is to test the ability of models to describe anisotropic turbulence. It is shown that the two-fluid model is more suitable for studying such flows.
2
PL
Podstawowy obszar aplikacyjny termoanemometrów stanowią pomiary fluktuacji prędkości przepływu gazów w szerokim spektrum częstotliwości. Istotną cechą termoanemometrycznych systemów pomiarowych jest więc możliwie duże pasmo przenoszenia sygnału pomiarowego. Standardowo szerokie pasmo przenoszenia uzyskuje się poprzez zastosowanie stałotemperaturowego trybu pracy anemometru. W trybie tym temperatura grzanego elementu pomiarowego utrzymywana jest na stałym poziomie dzięki zastosowaniu układu elektronicznego ze sprzężeniem zwrotnym. Pasmo przenoszenia dla termoanemometrów stałotemperaturowych może sięgać setek kiloherców. Ponieważ czujnik termoanemometryczny stanowi pod względem elektrycznym rodzaj pętli indukcyjnej, mogą indukować się w nim zakłócenia elektromagnetyczne. Duże wzmocnienie oraz szerokie pasmo przenoszenia układu stałotemperaturowego powodują, że w przypadku występowania zakłóceń elektromagnetycznych udział sygnałów niepożądanych w sygnale wyjściowym termoanemometru może być znaczący. W pracy tej przedstawiono koncepcję metody eliminacji tych zakłóceń.
EN
The main application area for hot-wire anemometers are measurements of gas flow velocity fluctuations in a wide range frequency spectrum. An important feature of hot-wire anemometric measuring systems is therefore the highest possible frequency bandwidth of the measuring circuit. As a standard, a wide frequency response is obtained by using a constant temperature mode of the anemometer. In this mode, the temperature of the heated measuring element is kept constant, by the use of an electronic system with feedback. The frequency response for constant temperature anemometers can reach hundreds of kilohertz. Since the hot-wire sensor is a kind of induction loop in electrical terms, electromagnetic interference may be induced in it. The high gain and the wide frequency bandwidth of the constant temperature system mean that in the event of electromagnetic interference, the share of unwanted signals in the output signal of the anemometer can be significant. This work presents the concept of the method for eliminating these disturbances.
PL
Pomiary fluktuacji prędkości stanowią główny obszar aplikacyjny termoanemometrów. Dlatego też wyznaczenie pasma przenoszenia termoanemometru stanowi ważne zagadnienie dla oceny jego właściwości metrologicznych. Standardowa, pośrednia metoda wyznaczania pasma przenoszenia termoanemometru polegająca na podłączeniu przewodowo do elektronicznego układu termoanemometrycznego periodycznego, testującego sygnału napięciowego. Na podstawie odpowiedzi termoanemometru na taki sygnał można oszacować pasmo przenoszenia termoanemometru. W artykule proponuje się modyfikację metody z periodycznym sygnałem testującym. Modyfikacja polega na bezprzewodowym doprowadzeniu elektrycznego sygnału testującego do czujnika pomiarowego poprzez transformatorowe sprzężenie indukcyjne.
EN
Measurements of gas velocity fluctuations constitute the main application area of hot-wire anemometers. Therefore, determining the frequency response of the hot-wire anemometer is an important issue for the assessment of its metrological properties. A standard, indirect method of determining the frequency response of a anemometer consists of use of an periodic testing signal connected directly to the anemometer circuit. Based on the response of the anemometer to such a signal, the frequency response can be estimated. The article proposes to modify the method with a periodic test signal. The modification consists in wireless connection of the electrical test signal to the measuring sensor via transformer inductive coupling.
EN
In this paper, we examine the zero-fourth cumulant approximation that was applied to fluctuating velocity components of homogeneous and isotropic turbulence by M.D. Millionschikov. Since the publication of the remarkable paper of Millionschikov, many authors have applied this hypothesis to solve the closure problem of turbulence. We discuss here various studies by the other authors on the developments of this hypothesis and their applications to the incompressible velocity temperature, hydrodynamic and magnetohydrodynamic fluctuating pressure fields and the general magnetohydrodynamic turbulence field. Lastly, we discuss broadly the computational difficulties that arise in turbulence problems and their possible refinements. We include also some enlightments of the process of future work that could be undertaken in this field of research.
PL
W pracy analizowano wewnętrzną strukturę turbulencji przepływającego w tunelu powietrza, dla różnych prędkości średnich. W tym celu wykorzystano jednopunktowe korelacje fluktuacji prędkości określone w tym samym punkcie w przestrzeni i w tej samej chwili. Przytoczone zostały podstawowe wzory na jednopunktową korelację fluktuacji prędkości. Wykorzystując dane uzyskane z pomiarów prędkości, określono korelację czasową opisującą statystyczną zależność między dwoma chwilowymi wartościami jednej i tej samej wielkości fizycznej, opóźnionej o wartość τ. Funkcje autokorelacji i współczynnik korelacji czasowej stanowiły podstawę wyznaczenia mikroskali i mikroskali czasowej, które charakteryzują najszybsze i najwolniejsze zmiany zachodzące w strukturze turbulencji tj. drobno i wielkoskalowe wiry.
6
Content available remote Badanie charakterystyk eksploatacyjnych maszyn technologicznych
PL
W pracy określono strukturę jakości maszyn technologicznych, z uwzględnieniem czynnika eksploatacji. Biorąc pod uwagę tę strukturę opracowano metodykę badań. Przedstawiono przykładowe wyniki badań porównawczych, dotyczących nowych oraz po okresie eksploatacji maszyn technologicznych (obrabiarek). W badaniach skoncentrowano się na pomiarach dokładności pozycjonowania i zmian prędkości ruchu układu suportu. Otrzymane wyniki dokładności pozycjonowania dowiodły istnienia znaczących zmian w charakterystyce pozycjonowania spowodowanych użytkowaniem maszyn. Wykazano nierównomierne zużycie zespołu prowadzącego łącznie z zespołem napędowym w poszczególnych przedziałach ruchu. W odniesieniu do badania zmian prędkości przesuwu zaobserwowano różnice w przebiegach charakterystyk rozruchu i hamowania, zależnie od parametrów nastawczych maszyny. Na podstawie otrzymanych rezultatów badań sformułowano wnioski i zalecenia.
EN
The paper presents a quality structure of machine tools with regards to performance. Basing on this structure a research methodology has been developed. Example results of comparison tests have been presented for both new and used machine tools. The research focused on positioning accuracy and support speed variation. Obtained results have showed significant changes of machine performance due to its usage. Non constant wear of driving unit in different ranges of movement bas been proved. Variation of movement velocity has been observed in relation to set parameters of the machine tool. Basing on obtained results conclusions and practical recommendations have been made.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.