The necessity of development of technical solutions that will allow to reduce carbon monoxide emissions of flue gases of industrial productions is substantiated. It is shown that the most rational design solution to the problem of carbon monoxide pollution during the firing of electrode blanks is the use of aerated concrete blocks with a catalyst, which can be quickly and conveniently located directly on the carbon material of the “green” electrodes pouring in the subfloor space of the firing furnaces. Modified by oxides of Mn4+, Fe2+, Fe3+, Cu2+, Cr3+ -catalysts based on aerated concrete were obtained. It is shown that in an empty reactor in the temperature range 200–400 °С the degree of conversion of carbon monoxide in the absence of a catalyst is zero. It is established that on the investigated catalysts based on aerated concrete 100% oxidation of carbon monoxide is achieved at a temperature of 390 °C in the case of using a mixture of catalyst powders 30% CuO + 70% MnO2, 40% CuO + 60% MnO2, 50% Fe (FexCr1-x) 2O4 + 50% MnO2; 50% Fe3O4 + 50 % MnO2. It is determined that the addition of ferrite catalyst powder in aerated concrete in a mixture or without manganese dioxide does not critically affect the mechanical properties of the products.
EN
The catalysts based on natural zeolite-clinoptilolite of Sokyrnytsia deposit modified with oxides of Mn4+, Fe2+, Fe3+, Cu2+, Cr3+ were synthesized. It was determined that 100% conversion of carbon monoxide was achieved at a temperature of 390°C when using the copper-manganese-oxide catalyst (30% CuO + 70% MnO2). It was shown that although the use of the manganese-oxide catalyst provided 92.8% of CO conversion degree, this catalyst had the most advantages for application compared to the other studied solids. The structural parameters of the manganese-oxide catalyst were determined using XRD, SEM, and nitrogen adsorption. The composition of the main elements of the catalyst samples was determined by micro-X-ray spectral analysis. It was shown that using the catalyst containers in chambers heated by flue gases in the fire channels of a multi-chamber furnace for baking of electrode blanks can be one of the constructive solutions to the problem of flue gas purification from carbon monoxide. The environmental safety of the copper-manganese-oxide catalyst application for the treatment of the flue gases of electrode production is justified by obtaining a catalyst from spent sorbents for purification of the manganese-containing natural water and its non-toxicity in the case of burial or storage in landfills.
EN
Metallurgy, as one of the oldest industries, is currently experiencing a technological boom in an effort to increase production efficiency with the least possible impact on the environment. Modeling methods make it possible to design and simulate a technological process or technological equipment for conditions that take into account the above-mentioned aspects. For this reason, the article focuses on the use of simulation modeling using accessible computer technologies in order to improve the operation of heating aggregates with the metal-bearing batch, such as a continuous heating furnace. The paper describes the methodology for modeling the flow of flue gases in the working space of a gas heating furnace, which results in their enthalpy representation. A simulation study was performed for a gas-fired furnace used to heat gates. Three case studies were simulated with set values of on and off burners and fuel flow to them. The effect of these parameters on the total amount of recirculated flue gas was investigated. The results showed that the fuel flow regulation to the burners at the material inlet into the furnace had a higher effect on the overall recirculation than the switching on and off the burners on the furnace's outlet side. The results pointed to critical points on the inner shell of the furnace, which could be the most critically thermally stressed, for example, in the places of the collision of opposing flue gas flows.
PL
Dyrektywy Unii Europejskiej dotyczące zmniejszenia emisji tlenków azotu (NOx) do atmosfery przez przemysł energetyczny wymuszają stosowanie nowych technologii odazotowania spalin. Taki proces może negatywnie wpływać na jakość ubocznych produktów spalania (UPS) [1–2]. Dlatego podjęto badania mające określić wpływ zawartości amoniaku na właściwości popiołów lotnych. Objęto nimi popioły lotne krzemionkowe ze spalania węgla kamiennego oraz popioły fluidalne ze spalania węgla brunatnego. Dla wytypowanych próbek popiołów pochodzących z instalacji, w których wprowadzono system odazotowania spalin, oznaczono zawartość amoniaku w suchej masie oraz w wyciągu wodnym. Określono wpływ zawartości amoniaku w popiołach lotnych na właściwości wytrzymałościowe cementów z ich udziałem. Wykonano również analizy wpływu czasu wietrzenia na zawartość azotu amonowego w suchej masie popiołów. Do zbadania procesu wydzielania się amoniaku zastosowano metodę analizy termicznej.
EN
European Union imposes ordinances which referred to reduction of nitrogen oxides emission to atmosphere emitted by energy industry. New flue gasses denitrification technologies have to be applied to cope with that directives. Unlikely this process may negatively influence on the combustion by-products quality. For this reason the research aimed to test the influence of ammonia content in fly ashes on their properties had been proceeded. In this research the fly ashes from conventional combustion of coal and FBC (fluidized bed combustion) fly ashes from combustion of lignite were used. For chosen fly ash samples originated from flue gas denitrification installations, the ammonia content in dry mass and water extracts was tested. Moreover the influence of ammonia content in fly ashes on strength of cement-ash mortars was studied. The effect of airing time on ammonia quantity in dry mass was analyzed. To investigate the process of ammonia evolution, the differential thermal analyses were carried out.
EN
With the rapid development of shipbuilding industry exhaust world is also very harmful one kind of environmental issues, and the ship marine diesel engine exhaust gas is mainly produced, so in recent years it has developed a diesel engine SCR system. SCR system can control emissions of nitrogen oxides in the exhaust of vessel, furthermore air pollution can be reduced. The main goal of article was using fluent software to correct SCR system selection and flue gas flow under different size best deflector arrangement is simulated. Next goal is further optimize the structure of the SCR system.
6
Content available remote Analiza wybranych parametrów betonu siarkowego
PL
Prezentowane wyniki badań wytrzymałości (ściskanie i zginanie) oraz trwałości (mrozoodporność, mrozoodporność z udziałem środków odladzających, ścieralność, absorpcja wody) dotyczą betonu siarkowego wytworzonego z użyciem nowego typu zmodyfikowanego polimeru siarkowego. Siarkobeton jest materiałem, w którym rolę spoiwa przejmuje polimer siarkowy. W prezentowanych badaniach założono, że beton siarkowy powinien spełniać wymagania dotyczące trwałości i wytrzymałości, stawiane betonowym, drobnowymiarowym prefabrykowanym elementom infrastruktury drogowej. Wyniki badań pozwoliły określić obszar zastosowania tego materiału w budownictwie drogowym ze względu na dużą wytrzymałość, ścieralność i mrozoodporność jedynie powierzchniową. Niemożliwe jest jednak jego wykorzystanie w elementach infrastruktury drogowej, które wymagają spełnienia warunków mrozoodporności objętościowej.
EN
The results of strength tests (compression and tensile bending), durability tests (freeze – thaw resistance, deicing salt scaling resistance, abrasion, water absorption) presented in this paper refer to the sulfur concrete produced on the new type of modified sulfur polymer. The sulfur concrete is a material in which the modified sulfur polymer plays the role of a binder. It was established that produced sulfur concrete should meet the requirements specified for concrete members used in the road infrastructure including its mechanical and durability properties. The test results allow to state that the sulfur concrete is a material that can be conditionally used in the road infrastructure industry due to its high mechanical strength, abrasion and the only surface freeze – thaw resistance with deicing salts. However, it is not applicable for road infrastructure, which require the full volumetric freeze-throw resistance.
PL
Przeprowadzono serię badań na obiekcie rzeczywistym w zakresie zastosowania wodorowęglanu sodu w procesie suchego oczyszczania spalin powstających w wyniku spalania węgla kamiennego. Zbadano skuteczność sorbentu w reakcjach z substancjami kwasotwórczymi, którą wyrażono stopniem neutralizacji SO₂ i HCl w funkcji współczynnika stechiometrycznego reakcji oraz temperatury spalin, a także przeprowadzono analizę chemiczną składu produktów reakcji. Przeanalizowano parametry konstrukcyjne i procesowe instalacji oczyszczania spalin mające wpływ na przebieg sorpcji.
EN
NaHCO₃ was used as a solid sorbent for removing SO₂ and HCl from flue gas in a coal fired power plant under operation. The SO₂ and HCl neutralization degrees reached 81% und 98%, resp., under industrial conditions.
PL
W pracy przedstawiono wyniki badań nad efektywnością redukcji rtęci przy wykorzystaniu biowęgla z biomasy, uzyskanego w wyniku niskotemperaturowej pirolizy. Badania przeprowadzono na gazach odlotowych instalacji wypalania klinkieru pracującej w technologii metody suchej. Zastosowanie metody iniekcji pyłu biowęgla do tych gazów (T = 140°C, CO2 = 12%, SO2 = O%, H2O = 4%) w ilości 8,6–9,6 g/m3n skutkuje zmniejszeniem koncentracji rtęci o ok. 40%.
XX
The paper presents results of mercury reduction studies using biomass derived from low temperature pyrolysis of biomass. The research was carried out on waste gases from clinker burning plant using dry method technology. The application of the method of injection of biochar dust to these gases (T = 140°C, CO2 = 12%, SO2 = O%, H2O = 4%) in the amount of 8,6–9,6 g/m3n results in a reduction of mercury concentration by about 40%.
9
Content available remote Recovery and energy use of flue gas from a coal power plant
EN
The paper presents a technology for heat recovery from flue gas generated in power units of coal-fired power plants. The technology for heat recovery from flue gas is based on bringing the water vapor contained in flue gas to condensation. A thorough analysis was performed of the potential of recovering heat from gas formed through the combustion of coal and lignite. The results were confirmed experimentally at the laboratory scale and in a pilot-scale real facility. The test results were used in the formulation of conclusions and guidelines that will provide valuable insight to the design of a heat recovery system. The analysis and tests performed demonstrated that the recovery of waste heat from flue gas through the condensation of water vapor is justified only if the flue gas contains a lot of moisture, e.g. flue gas formed through the combustion of lignite.
EN
The present study aims at demonstrating how important it is to include the substantial increase in CO2 heat capacity around the critical temperature in the modelling of relevant PSA separations. It is shown that this parameter may considerably alter simulation results, especially in the cases when the adsorbed phase concentration is high, regeneration pressure is moderate and CO2 content in the enriched stream is large.
PL
Celem tej pracy jest zwrócenie uwagi na konieczność uwzględniania bardzo dużego wzrostu ciepła właściwego zaadsorbowanego ditlenku węgla w pobliżu temperatury krytycznej przy modelowaniu procesów wydzielania CO2 ze spalin metodą adsorpcji zmiennociśnieniowej. Wykazano, że przyjmowana w obliczeniach symulacyjnych takich procesów wartość ciepła właściwego fazy zaadsorbowanej wpływa znacząco na wyniki symulacji w sytuacji, gdy na złożu utrzymuje się duże stężenie ditlenku węgla, stosowane są umiarkowane ciśnienia regeneracji oraz otrzymuje się duże stężenie CO2 w gazie wzbogaconym.
PL
W artykule przedstawiono analizę możliwości wykorzystania ciepła odpadowego do produkcji energii elektrycznej z układów wypalania klinkieru zlokalizowanych w Polsce. Ilość dostępnego ciepła odpadowego uzależniona jest od zapotrzebowania ciepła w procesach suszenia surowców i paliw. Poziom wykorzystania entalpii gazów odlotowych w cementowniach waha się w graniach od 63 do 100%, natomiast dla powietrza nadmiarowego wynosi od 0 do 100%. Dla analizowanych instalacji wypalania klinkieru łączna moc turbozespołów wyniesie ok. 27,5 MWel, natomiast roczna produkcja energii elektrycznej wynosi potencjalnie 177 GWh.
EN
The paper presents an analysis of using waste heat for electricity production in clinker burning systems. The quantity of available waste heat depends on the heat demand in the raw materials and fuels drying process. The level of use of the enthalpy of exhaust gases varies from 63 to 100%, whereas the excess air is from 0 to 100%. Total turbine power will be approx. 27,5 MWel for the analyzed system clinker burning. While the annual electricity production is potentially 177 GWh.
EN
Cosmic-ray research which started just after the second world war in 1947, encouraged widespread use of radioactive particles in many areas of science and technology, starting from astronomy, chemistry, archaeology, biology, botany, medicine and lately ending with environmental studies. Method based on measurements of the radioactive elements remains in various samples (solid, liquid and gaseous) can be very useful tool for ecological and environmental analytical measurements. The 14C liquid scintillating counting method was used for simplified determination of the biomass content in flue gas from combustion processes or in the finished bio-product. Review of the latest results and progress in this research area shows the growth of interest from industrial sector in normalised method for biomass content determination.
EN
In Poland since 01.01.2016 enter into force the records of Industrial Emissions Directive (IED), which increasing the rate of installing flue gas denitrification devices (deNOx). Among the methods of limiting emissions of nitrogen oxides it is recommended to use cooperation of primary methods of reducing NOx emissions and recognized as BAT (Best Available Technology) methods SCR (Selective Catalytic Reduction) and SNCR (Selective Non-Catalytic Reduction) [1]. An alternative to the methods based on the ammonia use may become a method of NOx pre-oxidation. The method presented in the paper is based on oxidation by ozone the NOx and absorption of the oxidation products together with SO2 in absorber of WFGD system (Wet Flue Gas Desulfurization). In the paper the results of contamination removal efficiency based on the pilot-plant studies were presented. The pilot-plant was localized on the terrain of ZEC “Cogeneration” Wrocław. The results of these studies formed the basis of the preliminary draft of exhaust gas ozonation system for a coal-fired unit. The ozonation installation has to clean exhaust gases from SO2 and NOx to the level required by IED directive. Due to the widely use of the 200 MWe units in the Polish electric energy generating system one of such unit with the boiler OP 650 was selected for the design of deNOx system based on the ozonation method. It was assumed that the ozonation installation will be combined with the WFGD system operating on limestone. In the frame of the project demands for media and devices for deNOx and deSOx installations were calculated, and an economic analysis was conducted. The obtained results were compared with available data concerned to the SCR technology.
PL
Obowiązywanie w Polsce limitów emisji SO2, NOx i pyłów od 01.01.2016 roku zgodnych z dyrektywą IED (Industrial Emission Directive) wzmogło tempo instalowania urządzeń odazotowania spalin (deNOx). Wśród przedsięwzięć ograniczających emisję tlenków azotu zaleca się stosowanie współdziałania metod pierwotnych redukcji emisji NOx oraz uznanych za BAT metod SCR (Selective Catalic Reduction) i SNCR (Selective Non-Catalic Reduction) [1]. Alternatywą dla metod amoniakalnych może stać się metoda wstępnego utleniania NOx ozonem z absorpcją produktów utleniania razem z SO2 w absorberze MIOS (Mokra Instalacja Odsiarczania Spalin), którą prezentuje się w pracy. W pracy przedstawiono wyniki pomiarów skuteczności usuwania zanieczyszczeń ze spalin metodą ozonowania wykonane w skali pilotowej na obiekcie zlokalizowanym na terenie ZEC „Kogeneracja” Wrocław. Wyniki tych badań stanowiły podstawę do opracowania wstępnego projektu instalacji oczyszczania spalin dla kotła zasilanego węglem kamiennym. Instalacja ozonowania miała za zadanie oczyścić spaliny z tlenków azotu oraz dwutlenku siarki do poziomu gwarantowanego przez zapisy dyrektywy IED. Ze względu na powszechność stosowania w Polskiej energetyce bloków o mocy 200 MW, do projektu wybrano blok z kotłem OP-650. Instalacja ozonowania będzie współpracować z instalacją mokrego odsiarczania spalin. W ramach projektu wykonano obliczenia zapotrzebowania instalacji na tlen i ozon oraz wykonano analizę ekonomiczną. Otrzymane wyniki porównano z dostępnymi danymi literaturowymi dotyczącymi instalacji SCR.
14
Content available remote Symulacja wpływu temperatury na efekty odsiarczania spalin metodą mokrą
PL
Do oceny wpływu obniżenia temperatury spalin na przebieg ich odsiarczania zastosowano oprogramowanie ChemCad. Badania symulacyjne wykazały wpływ temperatury i innych zmiennych procesu na stopień odsiarczenia spalin, usunięcie ditlenku siarki oraz skład zawiesiny absorpcyjnej i tym samym na skład otrzymywanego gipsu. W zakresie 120-160°C wpływ temperatury spalin na efektywność ich odsiarczenia, skład gipsu, pH zawiesiny oraz przereagowanie kamienia wapiennego był niewielki. Zmiany temperatury spalin wprowadzanych do absorbera powodowały największe zmiany w zawartości pary wodnej w spalinach w wyniku odparowania wody z zawiesiny kamienia wapiennego w absorberze.
EN
Process for the flue gas desulfurization by absorption in CaCO3 suspension at 120-160°C was simulated to det. the effect of gas temp. on the process efficiency. The temp. showed a negligible effect on the final suspension temp. (64-66.5°) because of H2O evaporation.
PL
Przedstawiono wyniki badań procesu suchego odsiarczania spalin przy zastosowaniu wapna palonego CaO jako sorbentu, których wyniki porównano z uzyskanymi w procesie suchego odsiarczania wapieniem. Badania przeprowadzono na laboratoryjnym stanowisku pilotowym do spalania paliw w cyrkulacyjnej warstwie fluidalnej o mocy 0,1 MWth. Jako paliwo zastosowano węgiel brunatny, krajowy o średniej zawartości siarki 0,62% mas. sorbenty były wprowadzane wraz z paliwem bezpośrednio do komory spalania kotła, przy stosunku molowym Ca/S = 2, 3 lub 4. Wyniki przeprowadzonych badań wykazały wyższą skuteczność odsiarczania spalin przy zastosowaniu wapna palonego w porównaniu z wapieniem, średnio o 11%.
EN
CaO was added to lignite (S content 0.62% by mass) combusted in a lab. pilot plant with circulating fluidized bed (thermal capacity 0.1 MW) to compare its efficiency in flue gas desulfurization with limestone. The sorbents were fed in the combustion chamber directly with the fuel (mol. Ca/S ratios 2, 3 and 4). The addn. of CaO resulted in increase in desulfurization efficiency by 11% when compared with the use of limestone.
PL
W artykule przedstawiono wyniki badań dotyczące wybranych właściwości tekstury zaprawy pobranej z komina murowanego. Długoletnia eksploatacja komina sprzyja kumulacji zarówno w cegle ceramicznej, jak i zwłaszcza w zaprawie, składników spalin i produktów korozji. Ich obecność zmienia teksturę, mikrostrukturę i strukturę porowatości zapraw. Celem wykonanych badań było określenie kategorii porów, które stanowią priorytetowe miejsce kumulacji produktów korozji. Ponadto wykonano badania mikrostrukturalne, w których przedstawiono rozkłady powierzchniowe wybranych pierwiastków. Uzyskane mappingi są odzwierciedleniem stopnia skażenia badanej zaprawy.
EN
The article presents the results of research on selected properties of mortar taken from a masonry chimney. Long-term operation is conducive to the accumulation in ceramic brick and mortar, especially in exhaust components and corrosive products. Their presence changes the texture, microstructure and pore structure of mortars. The aim of the study was to determine pore diameter, which are the primary place, accumulation of corrosive products. Moreover, in the studies mapping of selected elements was performed. The resulting mappings are a reflection of the degree of contamination in the test mortar.
17
Content available remote Modelowanie procesu odprowadzania mokrych spalin w kominach przemysłowych
PL
Mokre spaliny powstające w wyniku odsiarczania spalin są potencjalnie agresywne dla konstrukcji komina oraz środowiska w przypadku ich niewłaściwego odprowadzania do atmosfery. Odprowadzanie mokrych spalin jest złożonym zagadnieniem mechaniki gazu, przepływu ciepła i masy. Wartykule przedstawiano ogólną koncepcjęmodelowania tego zagadnienia, wyróżniając kilka elementarnych procesów. W szczególności praca zawiera wyniki modelowania i numerycznej analizy pierwszych dwóch wyróżnionych procesów dla kilku typowych schematów przewodu kominowego stosowanych w praktyce.
EN
Wet fumes exhausted from desulfurization system are potentially aggressive for chimney concrete shell and natural environment when gases are emitted to atmosphere not properly. Wet gases expulsion is a complex problem of fluid mechanics, heat transfer and mass transport. A general idea for modelling the problem mentioned above, which splits phenomenon into elementary processes, is presented in the paper. In particular the paper contains modelling description and numerical analysis results of fluid flow and heat transfer processes for typical stack liner geometries installed in power-generation industry chimneys.
EN
Emission of toxic compounds the exhaust gas depends greatly on the engine condition. Therefore, the legislature makes the producers of vehicles with combustion engines have procedures for the detection of increased levels of toxic the exhaust gas emissions. The result is that systems whose function is to control emissions and control elements responsible for the safety of the vehicle. This problem is not solved in the case of vehicles with off-road applications, including use in underground mining. The current state of regulation in the field of toxicity testing does not require the manufacturers and users of these vehicles in service obligation of machines, which are issued periodically tested for emission control.
PL
Artykuł dotyczy badań toksyczności spalin emitowanych przez maszyny i pojazdy z napędem silnikowym, mające szerokie zastosowanie również w górnictwie podziemnym. Ten obszar badań nie jest dostateczne regulowany w świetle obowiązujących przepisów, szczególnie w trakcie bieżącej eksploatacji maszyn.
19
Content available Automatic control of concentration of flue gases
EN
Functional scheme of control subsystem of flue gas content by means of optic – absorption infrared method, compensating the impact of atmospheric dust and excess humidity is developed on the basis of boiler unit control system. Automatic control system provides high energy resources efficiency of boiler unit operation.
PL
Wykorzystując układ sterowania kotłownią, został opracowany funkcjonalny schemat systemu kontroli składu gazów dymowych na podstawie metody optyczno-absorbcyjnej infraczerwonej z kompensacją wpływu pyłu atmosferycznego i nadmiernej wilgotności. Fizyczne zasady działania tego systemu polegają na tym, że mierzy się pochłanianie optyczne wypromieniowanego gazu. Pod wpływem światła, które przechodzi przez gazowa kuwetę, molekuły gazu pochłaniając kwanty promieniowania pewnych częstotliwości, wzbudzają się. W zależności od składu gazu dymowego, infraczerwone widma pochłaniania molekuł (gazowej mieszanki) mają indywidualny charakter, który pozwala identyfikować konkretny gaz. System zawiera blok stabilizacji wejściowych parametrów, przetwornik pomiarowy, bloki przetwarzania i wizualizacji informacji. Dla obróbki informacji służy mikrokontroler firmy VIPA serii System 200 V; dla konfiguracji wykorzystali programowy pakiet WINPLC7, język programowania – Lauder Diagram. Zaproponowana technologia umożliwia wysoką wydajność energetyczną kotłowni.
EN
This review describes current issues concerning electron beam technology for the purification of flue gas from a coal-fired boiler. Fundamental studies of this technology were performed in a pilot plant at Kaweczyn Thermal Power Station. It is a dry scrubbing process ensuring the simultaneous removal of SO2 and NOx with high removal effciency in one step and the generation of a usable byproduct. NOx removal is performed by a radiation-induced process and its effciency depends mainly on absorbed dose and inlet NOx concentration. Higher gas temperature and multistage flue gas irradiation enhance NOx removal. The synergistic effect of high SO2 concentration on NOx removal was observed. The SO2 removal is based on two pathways: a thermal process (reaction of SO2 with ammonia in a moist environment) and a radiation-induced process. Its effciency depends mainly on ammonia stoichiometry and irradiated gas temperature and humidity. SO2 removal increases sharply as the irradiation dose increases to 8 kGy and then saturation is reached. The byproduct obtained can be used as an agricultural fertilizer or as a component for producing commercial NPK fertilizer. This technology has been already implemented on a full industrial scale at ”Pomorzany” EPS. This installation purifies up to 270,000 Nm3/h of flue gas from two coal-fired Benson boilers. The highest SO2 removal effciency obtained reaches 95% while for NOx it reaches 75%. Two-stage, longitudinal irradiation of flue gas enhances NOx removal effciency and reduces energy consumption in the process. During pilot plant operation it was proved that electron beam technology can remove SO2 and NOx simultaneously in a wide concentration range of SO2 (250...3,000 ppmv) and NOx (140...280 ppmv) with high effciency. New industrial implementations of this technology have been introduced in China and Bulgaria. This technology is designed for existing plants as a retrofit application as well as for new facilities.
first rewind previous Strona / 3 next fast forward last