Flow control in microchannels is one of the key issues in many areas of modern technology, such as medicine, bio-engineering, chemistry and, in recent years, also in problems of thermodynamic processes control. This paper presents the results of experimental studies on the dynamics of liquid movement between the walls of a microchannel, which is the effect of the electric field applied to the walls (the dielectrophoresis phenomenon). The presented results fill a gap in the literature, being also an important material for the determination of the device key parameters, such as the height of the microchannel electrodes, frequency and amplitude of applied voltage, the selection of periods with and without voltage, all of which affect the operation of the device.
PL
Kontrola przepływu w mikrokanałach jest jednym z kluczowych zagadnień w wielu obszarach współczesnej technologii, szczególnie w medycynie, bioinżynierii, chemii, a w ostatnich latach również w kontroli procesów termodynamicznych. Niniejszy artykuł prezentuje wyniki badań eksperymentalnych dynamiki ruchu cieczy pomiędzy ściankami mikrokanału. Ruch ten jest wywołany przyłożeniem do ścianek mikrokanału napięcia pola elektrycznego (zjawisko dielektroforezy). Zaprezentowane wyniki wypełniają lukę w literaturze przedmiotu, są również ważnym materiałem dla określenia kluczowych parametrów urządzenia takich jak wysokość elektrod mikrokanału, częstotliwość i wartość napięcia zasilającego, a także wybór przedziałów czasu pomiędzy okresami przykładania napięcia i jego braku. Wszystkie wymienione parametry wpływają na pracę urządzenia.
EN
Continuous flow left ventricular assist device (cf-LVAD) operating speed modulation techniques are proposed to achieve different purposes such as improving arterial pulsatility, aortic valve function or ventricular unloading etc. Although it is possible to improve the left ventricular unloading by modulating the operating speed of a cf-LVAD, it is still unclear what type of pump operating mode should be applied to generate a better left ventricular unloading. This study presents a comparison of different heart pump support modes including constant speed support, copulsative and counterpulsative direct cf-LVAD speed modulation and pump flow rate control to regulate the cf-LVAD operating speed. The simulations were performed using a cardiovascular system model, which consists of active left atrium and ventricle, mitral and aortic valve leaflets, circulatory loop and a cf-LVAD. The cf-LVAD was operated between 7500 rpm and 12,500 rpm with 1000 rpm intervals to simulate constant speed support. The same mean pump operating speeds over a cardiac cycle were applied in the direct operating speed modulation for the copulsative and counterpulsative direct speed modulation cf-LVAD support as in the constant speed support while the same pump-output over a cardiac cycle was applied to drive the pump in flow rate controlled copulsative and counterpulsative cf-LVAD support modes as in the constant speed support. Simulation results show that flow rate controlled counterpulsative pump support mode generates lower end-diastolic left ventricular volume and pressure–volume loop area while generating more physiological left ventricular volume signals over a cardiac cycle with respect to the other pump operating modes.
3
Content available remote Automation of direct measurement and control of volumetric flow
EN
The paper presents a method for direct measurement of volumetric flow using a measuring cylinder with a free dividing piston. Original schemes of sensors and actuators connection have been provided as well as both input and output signal processing algorithms. Moreover, the influence of the key hardware parameters to the measurement accuracy has been considered.
PL
Artykuł przedstawia metodę bezpośredniego pomiaru przepływu objętościowego z wykorzystaniem cylindra pomiarowego z wolnym tłokiem, Zaprezentowano oryginalne schematy połączeń czujników i aktuatorów, jak również algorytmy przetwarzania sygnałów wejściowych i wyjściowych. Przedyskutowano ponadto wpływ kluczowych parametrów sprzętowych na dokładność pomiaru.