1
Content available remote Resistance and stiffness of blind bolt lap joints in cold-formed steel structures
EN
The paper summarises the existing results of the authors’ own research in the range of design of lap-joints with blind fasteners Huck BOM of cold-formed steel profiles. Formulae for their resistance and stiffness have been proposed with reference to the Eurocode EC3. Investigations are part of the research, which aims to develop the structural system of lightweight steel halls. The aim of this article is a comprehensive presentation of basic issues related to the design of bar structures with such connections.
PL
W artykule zebrano wyniki dotychczasowych badań autorów w zakresie projektowania zakładkowych połączeń kształtowników giętych na łączniki jednostronne Huck BOM. Zaproponowano formuły do obliczania ich nośności i sztywności z odniesieniem do zapisów Eurokodu EC3. Badania są elementem programu, który ma na celu opracowanie systemu konstrukcyjnego lekkich hal stalowych. Celem artykułu jest kompleksowe przedstawienie podstawowych zagadnień związanych z projektowaniem konstrukcji prętowych z badanymi połączeniami.
EN
This paper presents the course and results of a research programme aimed at the determination of the design buckling resistance of an axially compressed RHS column strengthened using two shorter U-sections. Connections of the tube and the channel branches were fabricated using BOM blind fasteners. Results of the experimental tests demonstrated the satisfactory efficiency of the performed strengthening of the tubular bar. Parametric analyses performed based on the validated theoretical model allowed the identification of the key factors influencing the effectiveness and economic efficiency of the strengthening process.
PL
W artykule przedstawiono przebieg i wyniki programu badawczego, którego celem było określenie obliczeniowej nośności wyboczeniowej ściskanego osiowo pręta o przekroju rurowym prostokątnym, wzmocnionego za pomocą dwóch krótszych gałęzi ceowych. Połączenia gałęzi rurowej i ceowych wykonano przy użyciu łączników jednostronnych BOM. Wyniki badań wykazały zadowalającą skuteczność wzmocnienia. Analizy parametryczne wykonane przy użyciu modelu teoretycznego umożliwiły identyfikację kluczowych czynników wpływających na skuteczność i efektywność ekonomiczną procesu wzmocnienia.
PL
W artykule przedstawiono możliwość zastosowania łączników jednostronnych typu BOM w konstrukcjach budynków wykonanych z kształtowników giętych na zimno z blach. Zaletą konstrukcyjną proponowanego systemu prętowego jest możliwość wykorzystania w projektowaniu, kształtowników rurowych o przekrojach prostokątnych oraz racjonalnego kształtowania konstrukcji kratowych, z niewspółśrodkowym połączeniem prętów w węzłach bez blach węzłowych. Zaproponowana technologia połączeń gwarantuje łatwy i szybki montaż konstrukcji na placu budowy, z pojedynczych prętów. Przytoczono publikacje, umożliwiające projektantom zapoznanie się ze wzorami na nośność i sztywność dowolnego podatnego połączenia zakładkowego dwu blach o grubościach 4 i 5 mm – o dowolnych: liczbie łączników i ich rozmieszczeniu – poddanego złożonemu stanowi obciążeń. Omówiono także problematykę projektowania prętów złożonych blisko gałęziowych z podatnymi połączeniami gałęzi. Przedstawiono wyniki badań doświadczalnych tych prętów, wskazujące na konieczność uwzględniania w procedurze sprawdzania ich stateczności, przemieszczeń zachodzących w połączeniach gałęzi.
EN
The paper presents the possibility of application of blind bolts BOM in constructions of building structures made from cold-formed sections. The advantage of the proposed structural system is the possibility of using in the design process tubular sections with rectangular section and also rational shaping of lattice structures with eccentrically connected bars in the nodes, without gusset plates. The proposed technology ensures easy and quick assembly of the construction on building site, using individual bars. The publications were quoted, which enable designers to familiarize themselves with the formulas for the resistance and stiffness of any flexible, overlap connection of two sheets with thickness of 4 and 5 mm – of any: the number of fasteners and their arrangement – subjected to the complex state of load. The issue of designing built-up closely spaced bars with flexible connection of the branches was also discussed. Presented results of experimental studies indicate the necessity of taking into account displacements occurring in the connections of the branches, in the procedure of checking of stability of the bars under consideration.
EN
The paper presents the results of the experimental verification of the method of calculation of an m-bolt single-cut joint between two walls of cold-bent profiles, described in [2] and [3]. The author of [2] compared the numerical results, obtained by using this method, with the results of experimental investigations of a symmetrical 5-blind-bolt joint of walls 5.0 mm thick, made with blind-bolts BOM-R16 [1]. The paper contains a diagram illustrating the behaviour of a symmetrical 8-blind-bolt joint, loaded alternately by the bending moment šM, and the behaviour of a asymmetrical 4-blind-bolt joints, subjected simultaneously to bending and shearing. Also here the experimental results have been compared with the numerical results. It has been found out that in both investigated cases the rigidity was actually higher in the joints than calculated by means of the equations concerning this method. In both tested joints the loads were reiterated cyclically on stabilized levels. For the 4-blind-bolt joint the boundary curve of the load-carrying capacity was determined.
PL
Artykuł przedstawia wyniki doświadczalnej weryfikacji metody obliczania m-sworzniowego połączenia 1-ciętego ścianek kształtowników giętych na zimno, opisanej w pracach [2] i [3]. Porównano tam wyniki numeryczne uzyskane tą metodą z rezultatami badań doświadczalnych na przykładzie symetrycznego połączenia 5-sworzniowego ścianek o grubości 5,0 mm, wykonanego za pomocą sworzni jednostronnych BOM-R16 [1]. W niniejszym artykule zilustrowano na wykresach zachowanie się symetrycznego połączenia 8-sworzniowego, obciążonego naprzemiennie momentem zginającym šM, a także niesymetrycznego połączenia 4-sworzniowego, które poddano równoczesnemu zginaniu i ścinaniu. Porównano także wyniki doświadczalne z numerycznymi, stwierdzając w obu badanych przypadkach większą sztywność rzeczywistą połączeń w stosunku do sztywności obliczonej na podstawie równań sprawdzanej metody. Obciążenia obu badanych połączeń powtarzano cyklicznie na ustalonych poziomach. Dla połączenia 4-sworzniowego sporządzono krzywą graniczną nośności.
5
Content available remote Investigations and calculation of lap joints with special blind bolts
EN
In order recognize the behavior of joints joined by means of special blind bolts, in thin-walled structures, the author has tried to solve this problem analytically in connection with an experimental verification of exemplary calculations. Basing on his own investigations he has set up a regression curve for one single blind bold, describing the relation between load and displacement. The regression function was introduced into a set of equations, which permits to calculate any arbitrary multi-bolt joint, simultaneously loaded with the bending moment and the shearing force. The results of numerical calculations concerning a five-blind-bolt joint in the case of a proportional increment of partial loads, were checked experimentally. Thus, a good agreement of both numerical and experimental results has been obtained. By means of the suggested set of equations the interactive influence of the shearing force on the load-bearing capacity and rigidity of the investigated joint has been illustrated. Besides that, boundary curves of the load-bearing capacity of the joint have been plotted.
PL
Celem rozeznania zachowania się w konstrukcjach cienkościennych połączeń na łączniki sworzniowe podjęto w artykule próbę rozwiązania tego zagadnienia na drodze analitycznej, z doświadczalną weryfikacją obliczeń przykładowych. Na podstawie badań własnych ustalono dla pojedynczego sworznia jednostronnego krzywą regresji, opisującą zależność obciążenie-przemieszczenie. Funkcję regresji wprowadzono do układu równań, pozwalającego obliczać dowolne połączenie wielo sworzniowe, równocześnie obciążone momentem zginającym i siłą ścinającą. Wyniki obliczeń numerycznych uzyskane dla połączenia 5. sworzniowego, w przypadku proporcjonalnego narastania obciążeń składowych, sprawdzono doświadczalnie. Uzyskano dobrą zgodność wyników numerycznych i doświadczalnych. Przy wykorzystaniu zaproponowanego układu równań zilustrowano graficznie wpływ interakcyjny siły ścinającej na nośność i sztywność połączenia. Sporządzono także krzywe graniczne nośności połączenia.