Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 29

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  fires
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available remote Z orbity widać ogień w Ukrainie
2
Content available remote Pogorzelisko w chmurze punktów
EN
This article discusses role of field artillery on battlefield and the current state of field artillery. The purpose of this article is to outline development directions of artillery capability. Army surface-to-surface indirect fires will have a crucial part on the future battlefield. Essential trends in field artillery include: increase in range of fires systems; develop and disseminate of multi-sensor active-seeker munitions; advancement automated command and control; develop and implementation systems order to protect ground forces and forward operating bases from the threat of rockets, artillery, and mortars (C-RAM).
PL
W artykule opisano opracowane na podstawie badań fizykalnych oraz numerycznych wymagania funkcjonalne dla systemów oddymiania klatek schodowych oraz możliwości ich praktycznego spełnienia. Z badań wynika również, że najwyższą efektywnością i niezawodnością charakteryzują się instalacje oddymiania z nawiewem o regulowanej wydajności. System oddymiania musi działać przy często dynamicznie zmieniających się warunkach przepływu powietrza i dymu. Podczas rozwijających się pożarów również istotne dla efektywności systemu parametry, takie jak poziom szczelności klatki schodowej, temperatura powietrza oraz gazów pożarowych, nie są wartością stałą. Dla zachowania akceptowalnego poziomu bezpieczeństwa osób znajdujących się w budynku wskazana jest odpowiednia regulacja wydajności instalacji nawiewnej.
EN
The article describes smoke removal systems from staircases developed on the basis of in-situ tests and numerical analyzes. The text presents functional requirements for this type of installation. The article presents the advantages of using a smoke removal system supported by variable compensation air. The described systems are able to function effectively in changing conditions that accompany evolving fires. This is necessary to maintain an acceptable level of safety for people in the building. The described solutions meet the requirements of Polish fire protection regulations, and their application is in line with the principles of technical knowledge.
PL
W ostatnich latach w wyniku pożarów ucierpiało wiele cennych obiektów sakralnych i zabytkowych. W artykule dokonano przeglądu przepisów ppoż. ze szczególnym uwzględnieniem obiektów zabytkowych. Omówiono także zalecenia dotyczące projektowania sygnalizacji pożarowej oraz stałych urządzeń gaśniczych. Dążąc do jak najlepszego zabezpieczania nie tylko obiektów, ale i znajdujących się w nich zabytków i dóbr kultury, można wykorzystać systemy sygnalizacji pożaru, monitoring straży pożarnej oraz stale urządzenia gaśnicze, w tym instalacje mgły wodnej.
EN
In the period of several recent years many historic and valuable sacral buildings suffered from fires. In this article, a review of existing regulations have been done with a special focus in historic buildings rules. Recommendations concerning fire alarm systems and extinguishing systems have been elaborated. Aiming for the best possible fire protection for such buildings and cultural goods inside fire detection combined with fast fire alarm signal transmission to the Fire Station as well as extinguishing system including mist system may be used.
EN
This is a second part of the article in which the authors attempt to present the courses of action of the Territorial Defence Forces’ subunits in the conditions requiring the support of state and territorial administrations when life of residents is jeopardized as a result of catastrophes and natural disasters. This is one of the key tasks faced by the newly established Territorial Defence Forces (WOT) that is the protection of people and property within the activities unrelated to the kinetic impact of potential enemies.
EN
The authors attempt to present in the article the courses of action of the Territorial Defence Forces’ subunits in the conditions requiring the support of state and territorial administrations when life of residents is jeopardized as a result of catastrophes and natural disasters. This is one of the key tasks faced by the newly established Territorial Defence Forces (WOT) that is the protection of people and property within the activities unrelated to the kinetic impact of potential enemies.
PL
Technologia bezzałogowych statków powietrznych (BSP) znajduje coraz większą popularność i zastosowanie w codziennym życiu. W artykule przedstawiono analizę możliwości ich wykorzystania w działaniach Państwowej Straży Pożarnej (PSP) oraz propozycję cech BSP dedykowanego do działań PSP. W artykule zostały opisane dotychczasowe badania oraz sposoby wykorzystania BSP, a także eksperyment z wykorzystaniem środowiska symulacyjnego. Na ich postawie zaproponowano rozwiązania, jakie powinny być zastosowane w BSP używanych przez strażaków.
EN
The article is an analysis of the unmanned aerial vehicles idea of using them in fire -fighting operations. The first part defines the unmanned aerial vehicles and shows their main characteristics. Next chapters describe the possibilities of using them in fire -fighting actions. The last part of the article points out the requirements for equipment necessary for fire -fighting.
EN
Aim: The purpose of this study is to expose existing mathematical models dealing with heat and gas exchange, and reduce them to a single transfer equation, for any substance, during fire incidents inmines and other locations, by taking account of heated gas thermal expansion. Introduction: In order to perform an assessment of a fire hazard it is necessary to know the duration of a fire and period in which the fire will reach dangerous levels such as: concentration of toxic gases and saturation by smoke. A fire, manifested by an uncontrolled burning activity is a diffucult, unstable and ultimately not fully understood process, which occurs within a three dimensional expanse. This process is described, in the main, by mathematical equations dealing with behaviour principles involving conservation and conversion of energy, convection and diffused transfer of various gas components as well as smoke. Methods: In order to obtain anequation describing the transfer process for any substance, use is made of the central (finite) differences numerical method, for explicit and implicit conditions, using specific weighting appropriate to each. Results: The study examined the flow of air at velocities below the speed of sound – at less than 10m/s. According to the Bernoulli equation pressure changes insignificantly in relation to atmospheric pressure at such speed. Therefore, an equation describing this condition can be satisfactorily interchanged with an equation for normal conditions. This made it possible to depict a system of equations, in a dimensionless form, to address the behaviour and transformation of energy as well as convective and diffused transfer of components for different gasses and smoke using one universal equation. A numeric approach was developed to address issues. The designed calctulation diagram, incorporating explicit and implicit conditions is realised with the use of a “Miedwiedzcia” template. Specific examples illustrate comparisons between proposed calculations and graph analysis of variations in time and range of heat, and gas release in a ventilated channel. Conclusions: The article advocates a universal solution in a dimensionless form, which with the use of one equation describes a system of equations for conserving and transformation of energy, and transfer of different gas and smoke components by convective and diffused methods. The “Miedwiedzcia” template facilitates the capture of data dealing with the dynamics of heat and gas transfer processes in channels, corridors and mines.
PL
Cel: Celem badań jest generalizacja istniejących modeli matematycznych wymiany masy i gazów oraz stworzenie na ich podstawie jednego równania transferu dowolnej substancji podczas pożarów w kopalniach i w innych obiektach z uwzględnieniem rozszerzenia cieplnego gazów. Wprowadzenie: Aby przeprowadzić ocenę zagrożenia pożarowego, należy znać czas trwania pożaru oraz czas, w jakim osiągnie on niebezpieczne wartości np. stężenia toksycznego gazu i zadymienia. Prawdziwy pożar, będący niekontrolowanym procesem spalania, jest złożonym i nie do końca poznanym procesem niestacjonarnym, który odbywa się w przestrzeni trójwymiarowej. W celu opisania tego procesu wykorzystywane są głównie: równania zasady zachowania i przemiany energii, równanie konwekcyjno-dyfuzyjnego transferu składników różnych gazów i równanie konwekcyjno-dyfuzyjnego transferu dymu. Metody: W celu otrzymania rozwiązania równania transportu dowolnej substancji wykorzystano metodę liczbową różnic skończonych schematów jawnych i niejawnych z określonym ciężarem właściwym jednej z nich. Wyniki: Rozpatrywano przepływ powietrza z prędkością mniejszą niż prędkość dźwięku, poniżej 10 m/s. Przy takich prędkościach, zgodnie z równaniem Bernoulliego, ciśnienie zmienia się nieznacznie w stosunku do ciśnienia atmosferycznego. Dlatego też równanie stanu z dostatecznym stopniem dokładności można zamienić na równanie dla normalnych warunków. Pozwoliło to przedstawić w postaci bezwymiarowej system równań zachowania i przemiany energii oraz konwekcyjno-dyfuzyjnego transferu składników różnych gazów i dymu w jednym uniwersalnym równaniu. Opracowano metodę liczbową rozwiązywania zagadnienia. Przedstawiony łączony schemat obliczeniowy – jawny i niejawny jest realizowany na sześciopunktowym szablonie „Miedwiedzica”. Na konkretnych przykładach przedstawiono porównanie zaproponowanej metody liczbowej z analitycznymi krzywymi zmiany w czasie i w różnych odległościach funkcji wydzielenia ciepła i gazu w wentylowanym kanale. Wnioski: Zaproponowano uniwersalne rozwiązanie w formie bezwymiarowej, które opisuje jednym równaniem system równań zachowania i przemiany energii, konwekcyjno-dyfuzyjny transfer składników różnych gazów i dymu. Przedstawiono schemat obliczeniowy „Miedwiedzica”, który dzięki zastosowaniu metody liczbowej pozwala otrzymać wiarygodne dane o dynamice procesów wymiany masy i gazów w kanałach, korytarzach i kopalniach.
PL
Artykuł prezentuje historię, organizację oraz prawne aspekty ratownictwa morskiego. Omówiono wyposażenie Morskiej Służby Poszukiwania i Ratownictwa oraz jednostek współdziałających. Scharakteryzowano specyfikę pożarów na jednostkach pływających. Wskazano na konieczne zmiany systemie prawnym i szkolenia.
EN
The article presents the history, organization and legal aspects of the search and rescue operations at sea, as well as the specialized equipment of the Polish Maritime Search and Rescue Service and other assisting services. Characteristics of fires on the sea vessels are presented. Moreover, the needful changes in the legal and training system are pointed out.
11
Content available remote Przyczyny wypadków i pożarów na statkach morskich
PL
W artykule przedstawiono wykres struktury przyczyn wypadków statków morskich w latach 2004–2007 i 2009–2014, przygotowany na podstawie przepisów IMO (MSC-MEPC.3/Circ.3.Rev.1, 2014), oraz domniemane przyczyny powstawania pożarów na statkach morskich. Zaproponowano także podział przyczyn pożarów przez określenie czynników wpływających na przyczyny pożaru w celu ich klasyfikacji, co wpłynie na bezpieczeństwo pracy na morzu.
EN
This paper conducts a diagram of structure of accidents causes on marine ships in years 2004–2007 and 2009–2014 based on IMO regulations (MSC-MEPC.3/Circ.3.Rev.1, 2014). It also presents alleged causes of fires on marine ships. In this article, the author proposes division of the causes of fires by identifying the factors affecting the cause of the fire in order to classificate them, which will affect work safety at sea.
EN
Transportation of liquid and gaseous fuels and chemicals, albeit not frequent, can lead to serious dangers for humans, the environment and property due to fires and explosions. The two most common transportation modes on land are tanker trucks and pipelines. The effects of fires and explosions in such transportations can be modelled successfully to describe observed damages, as discussed here for three different types of accidents, namely tanker trucks carrying liquefied natural gas (LNG) or liquefied petroleum gas (LPG), and a gas pipeline, resulting in ignition and explosion. The effects of overpressure due to explosion and of radiated heat by fires are effectively modelled. The methodology and the developed e-platform are valuable teaching tools for engineers and civic personnel in order to foresee and assess risk and accident consequences near inhabited areas, and/or to predict alternate routes.
PL
W artykule opisano koncepcję mobilnego systemu do obserwacji terenu w celu wykrywania ognisk pożarów. Podstawową funkcję w tym systemie spełnia bezzałogowy statek powietrzny wyposażony w wyspecjalizowane kamery telewizyjne i termowizyjne sygnalizujące obecność obszarów o podwyższonej temperaturze, które mogą zostać zidentyfikowane jako ogniska pożaru. System posiada możliwość dwukierunkowej komunikacji drogą radiową ze stanowiskiem dowodzenia i po drobnych modyfikacjach może być wykorzystany do monitorowania zdarzeń związanych z ochroną ludzi i mienia, a także z zapewnieniem bezpieczeństwa w warunkach zagrożenia klęskami żywiołowymi i terroryzmem. Ze względu na niewielkie dopuszczalne przepisami wysokości lotu uwzględniony zostanie układ sygnalizujący zagrożenie wynikające ze zbliżania się do napowietrznych linii wysokiego napięcia, który ułatwi bezkolizyjne ich ominięcie.
EN
This paper describes the concept of mobile system for observation of land in order to detect fire outbreaks. The primary function of this system meets the unmanned aerial vehicle equipped with a specialized television cameras and thermal imaging indicating the presence of areas with elevated temperatures, which may be identified as a fire. The system has the possibility of two-way radio communication with the position of command and after minor modifications, can be used to monitor events related to the protection of persons and property as well as ensuring security in conditions of vulnerability to natural disasters and terrorism. Due to the low altitude limit regulations will include a signaling system risks arising from the approximation of the overhead high voltage lines, which will help them bypass the collision.
PL
Cel: Artykuł jest ostatnią częścią cyklu publikacji pt. Ocena stopnia bezpieczeństwa w aspekcie statystyk zdarzeń PSP, zamieszczonych na łamach kwartalnika „Bezpieczeństwo i Technika Pożarnicza” CNBOP-PIB. Celem publikacji jest przegląd metodologii opisu przypuszczalnych przyczyn pożarów (PPP) w systemach raportowych straży pożarnych wybranych krajów Unii Europejskiej (UE). Artykuł dodatkowo przedstawia wyniki badań rozkładu PPP zarejestrowanych w Informacjach ze zdarzeń PSP za lata 2000-2012, dotyczących pożarów obiektów mieszkalnych w skali kraju (Polska) i miasta (Warszawa). Wprowadzenie: Wstęp do wprowadzenia to najistotniejsze wnioski z poprzedzających bieżący artykuł publikacji nt. oceny stopnia bezpieczeństwa w aspekcie pożarów [2], miejscowych zagrożeń [3] i czasowo-przestrzennej charakterystyki pożarów obiektów mieszkalnych (POM) Warszawy [4]. Wprowadzenie zawiera przegląd struktury opisu PPP wraz z dodatkowymi danymi dotyczącymi przyczyn pożarów, zawartymi w raportach polskiej, brytyjskiej, szwedzkiej, fińskiej, węgierskiej i rumuńskiej straży pożarnej. Dodatkowo zawiera zarys wybranych funkcjonalności systemów wspomagających raportowanie w Polsce, Szwecji i Finlandii. Metodologia: Badaniom poddano wyselekcjonowane z systemu raportowego PSP (SWD-ST) Informacje ze zdarzeń za lata 2000- 2012 dotyczące wyłącznie POM. Wyselekcjonowane zdarzenia poddano procesowi geokodowania i wizualizacji w skali kraju – na podkładzie siatki kartograficznej 25 km – oraz aglomeracji warszawskiej – na podkładzie siatki kilometrowej. Przedstawiono ranking powiatów (miast) z największą i najmniejszą liczbą POM. Opisano strukturę PPP zagregowanych do poziomu kraju i Warszawy. Zbadano częstości występowania 37 PPP w stosunku do liczby POM. Przyczyny zgrupowano do kategorii czynnika ludzkiego (spowodowane przez człowieka działającego w sposób bezpośredni lub pośredni), czynnika technicznego (wady urządzeń, instalacji lub innych elementów konstrukcyjnych budynku) i nieznanych. Wnioski: Wyniki badań wskazują na odmienną strukturę informacyjną systemów raportowych straży pożarnych UE w aspekcie przyczyn pożarów, jak również klasyfikacji zdarzeń. Na podstawie badań wnioskuje się, że najprawdopodobniej około 60% POM na poziomie kraju i 73% na poziomie miasta spowodowanych jest działaniem czynnika ludzkiego. Udział czynników technicznych kształtuje się odpowiednio na poziomie 19% i 11%, a nieznanych 21% i 16%.
EN
Aim: This paper is the last in a series of research articles on the “Assessment of safety levels in the context of fire statistics of the Polish State Fire Service” (PSFS) published in “Safety & Fire Service Techniques” quarterly journal. The main purpose of the paper is to present an overview of methodology used to describe possible fire causes (PPP) in selected fire incident reporting systems of EU member states. The article also classifies causes in residential building fires, registered in the Polish State Fire Service reports for the years 2000-2012. The study involves examination of residential fires which, occurred nationally (Poland) and at city level (Warsaw). Introduction: The starting point for this paper is provided by the most important conclusions from previous papers on the assessment of safety levels in context of fires [2], local hazards [3] and time and space related characteristics of residential building fires (POM) in the geographical information system (Warsaw case study) [4]. The introduction incorporates a review of PPP and data about causes of fires contained in reports produced by the Polish, British, Swedish, Finnish, Hungarian and Romanian Fire Services. This is followed by the authors’ description of the main functionality of the Polish and Swedish incident reporting software. Methodology: An analysis of data was performed for selected residential building fire incidents (POM), registered in the State Fire Service fire reporting system (SWD-ST) for the years 2000-2012. Data was geo-encoded and mapped on a 25 km cartography grid for national incidents and 1 km grid for the city of Warsaw. A ranking list of Administrative Districts (towns) was created, to reveal the highest and lowest number of residential fires (POM). The authors described the structure of PPP, contained in the Polish State Fire Service fire reporting system and explored the frequency distribution for each of them. The cause of fire was identified against one of three categories: human factor (caused directly or indirectly by humans), technical (caused by faulty devices, domestic appliances or other building structure defects) and unknown (unspecified). Conclusions: The results indicate differences in the fire cause description structure for EU fire services reporting systems and emergency calls classification. Based on research, it is presumed that probably 60% of residential building fires at national level and 73% in Warsaw were caused by the human factor. Technical factors were attributed to 19% and 11% incidents correspondingly, and other factors were attributed to 21% and 16% of incidents correspondingly.
PL
Cel: Celem artykułu, będącego trzecią częścią cyklu publikacji pt. Ocena stopnia bezpieczeństwa w aspekcie statystyk zdarzeń Państwowej Straży Pożarnej (PSP), jest czasowa i przestrzenna charakterystyka pożarów jedno- i wielorodzinnych obiektów mieszkalnych (POM) Warszawy. Poprzez charakterystykę czasową należy rozumieć rozkłady pożarów w funkcji godzin, dni tygodnia, miesięcy, kwartałów, zaś charakterystykę przestrzenną metody budowy map zagrożeń poparte analizą i dyskusją wyników badań. Wprowadzenie: Badania częstości występowania pożarów, miejscowych zagrożeń (MZ) oraz poszkodowanych odnotowanych w raportach Państwowej Straży Pożarnej (PSP) za lata 2007-2012 wskazują, jak istotną problematyką w działalności służb ratowniczych są zagrożenia generowane w obiektach mieszkalnych [1], [4]. Wprowadzenie zawiera najistotniejsze wnioski z poprzedzającej bieżący artykuł publikacji nt. oceny stopnia bezpieczeństwa w aspekcie statystyk pożarów [1] i MZ [4]. Wynika z nich, że częstość pojawiania się POM oscyluje w granicach 17% wszystkich pożarów, zaś współczynniki rannych i ofiar śmiertelnych kilkudziesięciokrotnie przewyższają współczynniki wypadkowości innych klas obiektów, osiągając odpowiednio 75% i 81% wszystkich poszkodowanych [1]. Koncentracja MZ w obiektach mieszkalnych sięga 31% wszystkich MZ z odsetkiem rannych na poziomie 8% oraz ofiar śmiertelnych 22% [4]. Dodatkowo autor przedstawia najważniejsze postulaty z przeglądu 14 wybranych anglojęzycznych pozycji literaturowych w zakresie metod i technik identyfikacji, szacowania, oceny zagrożeń pożarowych, uzasadniające podjęcie problematyki badawczej. Metodologia: Badania przeprowadzono w oparciu o informacje ze zdarzeń za lata 2000-2012 wyselekcjonowane z baz danych Komendy Głównej PSP. W części dotyczącej analizy danych przedstawiono wnioski w zakresie jakości bezpośredniego (współrzędne geograficzne) i pośredniego (dane adresowe) odniesienia przestrzennego raportów. Opisano procedurę generowania map wektorowych w systemie ArcGIS, którymi posłużono się podczas charakterystyki czasowo-przestrzennej. Przedstawiono dwie metody budowy map. Pierwsza na podstawie przynależności pożarów do obszarów miejskiego systemu informacji o osiedlach (MSI) – pożary ograniczone podziałem administracyjnym miasta, druga w oparciu o estymację gęstości skupień zdarzeń metodą KDE (ang. Kernel Density Estimation) – zdarzenia nieograniczone obszarem administracyjnym miasta. Wnioski: We wnioskach podkreślono, że POM mają tendencję do budowy wzorców czasowo-przestrzennych. Ich liczba nasila się w godzinach 7-20, z maksimum w godz. 18-20, po czym jednostajnie spada pomiędzy 21-4. W sezonie grzewczym (grudzień, styczeń luty) oraz miesiącach o wzmożonym ruchu dzieci i młodzieży (czerwiec, lipiec, sierpień) zauważa się zwiększoną ich liczbę. Gęstość pożarów jest większa dla obszarów o zwartej zabudowie mieszkalnej, z przewagą starych budynków mieszkalnych. Wnioski w zakresie metodyki budowy map zagrożeń to lepsze dopasowanie stopnia zagrożenia pożarowego poprzez zaimplementowanie metody KDE. Podkreślono, że warunkiem koniecznym podczas generowania map zagrożeń jest dokładne uzupełnianie raportów służb w zakresie współrzędnych geograficznych podczas zakładania kart zdarzeń zgłoszeń alarmowych (wybór, w miarę możliwości, danych adresowych zaimplementowanych w postaci rejestru TERYT [24] – system SWD-ST PSP) oraz tworzenia raportów.
EN
Purpose: This is the third in a series of four articles entitled “Assessment of Safety Level Based on the State Fire Service Statistics (SFS)”. The paper refers to the experimental research on spatial-temporal analysis of residential building fires that occurred in Warsaw. The temporal analysis means that the author described percentage distribution of residential building fires by categories of hours, days of week, months and quarters. Spatial characteristics shoud be understood as the techniques of residential building fires hazard maps development proven by the research and discussion on its results. Introduction: Research on the frequency of fires, local emergencies and injuries in residential buildings class definitely demonstrates that the issue of risks in residential buildings is very important for the emergency services [1], [4]. The introduction includes the essential conclusions from the previous papers on the assessment of safety level in the aspect of fires [1] and local emergencies [4]. According to the State Fire Service statistics for 2007-2012, residential fires constituted 17% of all fires. Injury (75%) and fatality rates (81%) related to this class of buildings are a few dozen times higher than in case of other classes [1]. The percentage of local emergencies emerging in residential buildings amounts to 31% of all local emergencies with the coefficients of injuries and fatalities constituting 8% and 22% respectively [4]. In addition, the introduction contains the most important postulates from the literature review of 14 selected English language papers on fire hazards identification, estimation and assessment methods, that motivated the author to carry out the research and write this article. Methodology: Research includes a selection of detached house fires and blocks of flats fires that had been registered in the National Headquarters of State Fire Service database between 2000 and 2012. The paper includes summaries on the quality of direct spatial reference (coordinates) and indirect spatial reference (address data) found in the fire reports. The methodology of geo-processing fire statistic into point class vector map that is suitable in geographical information system (GIS) is described too. GIS analysis of temporal characteristics of residential fires by the way of classification of the events by hours, days of the week and months is presented. The author compiled house fire hazard maps on the basis of 2 methods. The first one shows classification of cartography grid based on polyline estate vector map, where each cell’s grid has a parameter of the number of residential fires. The second one based on residential fire density vector map created by Kernel Density Estimation mapping method. Conclusions: It is underlined that residential buildings fires are characterised by spatial and temporal dependencies. The number of residential buildings fires rises between 7-20 o`clock, and is peaking at 18-20. Then the number declines between 21-4. It is proved that the number of house fires is the highest in November, December, January and during the time of holidays such as June, July and August. When the density of dwelling estates rises, the residential fire hazard rises too. One of the hint in the field of residential building hazard maps is to implement KDE GIS method. The method is based on the density of point class vector map (e.g. fires) and it does not involve administrative boundaries. The better coordinates and address data, the better quality of the hazard maps. It is suggested to fill in the emergency calls forms and fire reports with the address data from the registry (if possible). There is an example of registry called TERYT [24] that is kept in SWDST, Polish State Fire Service system.
EN
The occurrence of Pteridium spores - the common fire-adapted plant - was observed in Poland's Pleistocene (three interglacials and numerous interstadials) and Holocene pollen sequences. Until the onset of the middle Holocene, bracken was recorded relatively rarely. This marks climatic conditions with sporadic wildfires, followed by quick removal of the clones (or maintenance of the clones in a suppressed state) in the subsequent, post fire successional stages. In each interglacial we can also identify short periods (most often synchronous) of somewhat higher frequency of Pteridium, indicating a possible increase in natural fires as an effect of stormy conditions. These short periods are placed mainly within phases dominated by coniferous woodlands. The very high content of bracken found from a reanalysis of the long Saalian sequence at Ossówka as three regular culminations just above three non-tree phases, eastern Poland is the unique exception. To explain this we found the close modern analogue of the above phenomenon in the Alaskan region, at the boundary between the tundra and the boreal zone where in a very narrow forest zone, especially with the continental signature, lightning-initiated fires are very frequent (the edge effect). Pleistocene records of bracken during forest periods might indicate that thunderstorms and lightning strikes were responsible for its higher content. This is not to exclude the possibility that interglacial fires were set by Palaeolithic humans. However, it is more likely that the wildfires were utilized and to some extent controlled, especially at Ossówka, where the palaeolake existed for a long time after the interglacial; and this surely attracted the attention of game and humans. Our investigations show that rare, more abundant Pteridium in the Pleistocene sequences can be traced throughout the corresponding periods even at distant sites. This might be indirect evidence of a climatic pattern that promote stormy conditions and fires at that time. In the Holocene, different factors seem to be responsible for the long-term dynamics in Pteridium clones. Both in Poland and in adjacent areas bracken peaked in the middle Holocene from 8000 to 5000 BP, when this territory was occupied by deciduous woodlands. There is agreement that this is due to burning of forests by the hunter-gatherer societies of the Late Mesolithic. However, in spite of increased clearings in the subsequent phases bracken substantially decreased in abundance. This means first of all that fires rather than clearings were responsible for the rise in Pteridium spores in the Holocene pollen sequences.
PL
W warunkach gospodarki rynkowej ważne miejsce zajmuje logistyka. Z obszernej problematyki logistyki ciągle aktualnym jest funkcjonowanie łańcuchów dostaw. Funkcjonowanie łańcuchów dostaw może być zakłócone przez różne rodzaje zagrożeń. Jednym z zagrożeń są pożary. Podstawowym ogniwem łańcucha dostaw są magazyny. W artykule wskazujemy na skalę pożarów magazynów w Polsce. Każdy pożar powoduje zatrzymanie pracy magazynów, straty bezpośrednie a także straty w kooperacji z przedsiębiorstwami, produkcją, instytucjami finansowymi. W artykule przedstawiamy skalę pożarów i częstość występowania.
EN
One of the bases of logistics is supply chains. Threat to supply chains can occur in each cell, one of the links in supply chains are warehouses (warehouse management). Warehouses are vulnerable to fires. Accumulated assets in warehouses can be fire losses. In article we describe the scale of the phenomenon, and the incidence of fires. Additionally, we point to the hypothetical effects of fires in warehouses. We show that each warehouse fire causes multi-dimensional effects in other cells supply chains.
18
Content available remote Wieloparametrowe monitorowanie pożarów przenośników taśmowych
PL
W artykule przedstawiono sposób monitorowania i wykrywania zagrożenia pożarowego powstającego podczas eksploatacji przenośników taśmowych. Monitorowanie oparte zostało o nowe czujniki wieloparametrowe oraz wyznaczony wskaźnik pożarowy. Wykorzystano także metodę opartą na fizycznej charakterystyce rozwoju źródła pożarowego oraz metodę wnioskowania rozmytego. Przedstawiono również przykłady wykorzystania wskaźników pożarowych do analizy danych pożarowych zebranych podczas badań.
EN
The paper presents a method to monitor and detect fire hazards occurring during the operation of belt conveyors. The monitoring was based on new multi-detector sensors and a determined fire index. Additionally, two methods were used: the method based on physical characteristics of the development of a fire source and the fuzzy logic method. Finally, some examples were presented how to use fire indexes for the analysis of fire data acquired during tests and trials.
PL
W artykule przedstawiono strukturę i elementy systemu wykrywania pożarów na trasie przenośników taśmowych w kopalniach węgla kamiennego. System umożliwia wykrycie początkowej fazy pożaru na podstawie analizy pomiarów, realizowanych przez czujniki rozmieszczone wzdłuż trasy przenośnika taśmowego, kontrolujące atmosferę i temperaturę wokół przenośnika taśmowego. W skład czujnika wchodzą detektory: tlenku węgla, cyjanowodoru oraz czujniki dymu i przyrostu temperatury. Struktura systemu oparta jest o system SMP-NT/* lub RELIA (stosowany w kopalniach hiszpańskich). Dodatkową zaletą układu jest możliwość pracy lokalnej w systemie APIS RELIA, co daje możliwość zastosowania monitorowania zagrożenia poza środowiskiem kopalń. Badania systemu przeprowadzono w kopalni San Nicolas w Mides (Hiszpania) oraz sztolni doświadczalnej w CSRG Bytom. Do symulacji pożaru użyto kilku rodzajów próbek taśm produkowanych głównie w Polsce przez FTT Wolbrom oraz jedną próbkę taśmy używanej w kopalniach hiszpańskich przez koncern HUNOSA. Wyniki pozwoliły na opracowanie algorytmu wstępnego wykrywania zagrożenia pożarem na trasie przenośnika taśmowego.
EN
The article presents the structure and elements of the system for detecting fires occurring along belt conveyors in hard coal mines. The system enables to detect the initial phase of the fire based on the analysis of measurements carried out by sensors placed along the belt conveyor and monitoring the atmosphere and temperature around the conveyor. The sensor consists of the detectors of carbon oxide, hydrogen cyanide, smoke, and temperature. The system structure is based on the SMP-NT/* or RELIA systems. An extra advantage of the system is the possibility to work locally in the APIS RELIA system, which enables to monitor the hazard outside the mine. The system was tested in the San Nicolas mine in Mides (Spain) and in the experimental drift of the Mining Rescue Station in Bytom (Poland). The fire simulation was prepared with the use of several sample belts produced in Poland by FTT Wolbrom and one sample belt used in Spanish mines and produced by IIUNOSA. The results allowed to work out an algorithm for initial detection of fire hazards along belt conveyors.
EN
Problem of evacuation of mining crew from mine fire-hazarded ones has been discussed in the present study. In order to make analysis of the mine crew evacuation suitable simulation programs can be used. Such programs take under consideration individual characteristic features evacuated crew, variable terrain topography, and possibility of selection of various escape routes. Mine zone ventilated with U system was chosen for the analysis of crew evacuation in dependence on thermal power of the fire.
PL
W artykule przedstawiono zagadnienie projektowania ewakuacji załóg górniczych z rejonów kopalni zagrożonych pożarem. W celu analizy ewakuacji załogi można stosować programy symulacyjne, które uwzględniają indywidualne cechy ewakuowanych osób, zmienną topografię terenu, możliwości wyboru różnych dróg ewakuacji przez załogę. Analizie ewakuacji załogi został poddany rejon kopalni przewietrzany systemem U, dla którego wyznaczono czas ewakuacji pracowników w zależności od mocy cieplnej pożaru.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.