Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  firedamp
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The risk of uncontrolled escape of firedamp is one of the major manifestations of closing coal mines in the Ostrava – Karviná District in the Czech Republic. Mining activity was also carried out in areas close to urban or suburban development in the city of Ostrava, including its historical district. The article presents aspects of dealing with the hazards as well as measures that have been implemented with respect to the risk of uncontrolled escape of firedamp. It outlines some of the applied approaches and equipment, which can eliminate this hazard. The figures included in the article document the current state of the solution.
PL
Ryzyko niekontrolowanego wycieku metanu jest jednym z głównych argumentów osób opowiadających się za zamknięciem Kopalni w Ostrava – Karviná District w Czechach. Działalność kopalni prowadzona była również na obszarach będących blisko zabudowań miasta Ostrava i jego okolic, włączając w to dzielnice historyczne. W artykule opisane są aspekty radzenia sobie z zagrożeniami, jak również pomiary zastosowane z myślą o ryzyku niekontrolowanego wycieku metanu. Przytoczone są niektóre ze stosowanych metod i wyposażeń, które mogą wyeliminować zagrożenie. Ilustracje zamieszczone w artykule obrazują aktualny stan rozwiązań.
2
Content available remote The quality of electric power supplied into the grid by co-generation units
EN
This paper deals with the utilisation of firedamp for combined heat and electric power generation. The firedamp is gained from hard-coal mines and can be combusted in a co-generation units with gas-engine. This process involves more efficient utilisation of firedamp. The measurement results obtained on selected co-generation units are described in this paper. As far as the electric power supplied into the grid from cogeneration unit´s are concerned, these shall be considered with respect to the qualitative parameters, which should comply with stipulations of the CSN EN 50160 standard. The main advantages and disadvantages of co-generation units producing heat for hard-coal mine and electric power for export to the grid are described in the end of this paper.
PL
Opisano możliwość wykorzystania gazu kopalnianego do ogrzewania i wytwarzania energii. Gaz może być wykorzystany w kogeneratorze z silnikiem gazowym. Opisano wybrane systemy wytwarzania energii.
EN
The process of firedamps´ release into worked-out areas, which often communicate with the surface after stopping the coal mining activity is very topical problem in the region of Ostrava. Firedamps contain namely dangerous methane, which is a result of the coalification process. Contemporary findings in this area show that the outflow of firedamps into the atmosphere is above all related to barometer pressure´s development. In 1995, the realization of degassing wells was initiated in region of Slezská Ostrava. Within the fremawork of monitoring, methane concentrations, gas-air mixture amount and barometer rates are measured among others. This paper gives information about mathematic data processing originated from the monitoring unit of the degassing well used for leading of firedamps from the underground, which is situated in Slezská Ostrava region.
EN
The process of firedamps' release into worked-out areas, which often communicate with the surface after stopping the coal mining activity is very topical problem in the region of Ostrava. Firedamps contain namely dangerous methane, which is a result of the coalification process. Contemporary findings in this area show that the outflow of firedamps into the atmosphere is above all related to barometer pressure's development. In 1995, the realization of degassing wells was initiated in region of Slezska Ostrava. Within the framework of monitoring, methane concentrations, gas-air mixture amount and barometer rates are measured among others. This paper gives information about mathematic data processing originated from the monitoring unit of the degassing well used for leading of firedamps from the underground, which is situated in Slezska Ostrava region
PL
Gazy kopalniane występujące na wyeksploatowanych terenach górniczych stanowią poważny problem w rejonie Ostrawy. Gazy kopalniane zawierają metan powstający w procesie uwęglania. Z ostatnich badań na tym terenie wynika, że ilość uwalniających się do atmosfery gazów zależy przede wszystkim od ciśnienia barometrycznego. W 1995 r. w rejonie Slezskiej Ostrawy rozpoczęto budowę otworów do odmetanowiania. W trakcie monitorowania dokonano pomiarów ilości mieszaniny gaz-powietrze oraz ciśnienia barometrycznego. W artykule przedstawiono dane matematyczne pochodzące z monitoringu otworu do odmetanowienia w rejonie Slezskiej Ostrawy
first rewind previous Strona / 1 next fast forward last