Implementation of a vibroacoustic on-line diagnostics system for condition trend monitoring is advisable, because that system should enable to obtain early information about avalanche-like fault development. In order to eliminate strong magnetic fields impact on measurement signals, a fibreoptic measuring circuit was designed and realized. the tests of designed fibre-optic circuit proved that it can be successfully used for transmission of signals from measuring head to central measuring system. The preliminary investigations have shown that the computer-based diagnostics system using vibroacoustic processes allows to evaluate the condition of specific machine parts by means of comparative analysis of two vibratory characteristics: the reference one stored in computer memory, and the newly obtained one.
PL
W artykule podjęto problematykę implementacji systemu diagnostycznego czasu rzeczywistego maszyny papierniczej, z użyciem metody wibroakustycznej, z ciagłym monitorowaniem trendu zmian stanu technicznego umożliwiających uzyskanie odpowiednio wczesnej informacji, o lawinowo narastajacym procesie uszkodzenia. Przedstawiono również zaprojektowany i wykonany dla celów eliminacji wpływu na sygnały pomiarowe silnych pól elektromagnetycznych występujących obok maszyny (źródłem ich są silniki elektyryczne duzej mocy), światłowodowy tor pomiarowy. Przeprowadzone testy weryfikacyjne pracy opracowanego toru pomiarowego dowiodły, iż może on być z powodzeniem stosowany do transmisji sygnałów w takich warunkach. W artykule zaprezentowano główne założenia sprzętowe i programowe opracowywanego kompuerowego systemu diagnostycznego .