The calculations of stresses acting on the wall of a boiler drum during the start-up process are presented in this paper. Based on the temperature measurements, which were carried out to determine the temperature distribution along the circumference of the outer wall of boiler drum, the temperature at the inner wall surface is determined using the inverse methods. The computations are carried out for the whole operation cycle of the power plant. Therefore, the pressure and temperatures are updated at consecutive time steps. These parameters allow determining the maximum values of circumferential, axial and Von Misses stresses during the operation cycle of steam boiler.
PL
W pracy przedstawiono obliczenia naprężeń w przekroju poprzecznym walczaka kotła OP-210 podczas jego rozruchu. Na podstawie pomiarów uzyskano wartości temperatury powierzchni zewnętrznej ścianki walczaka oraz poziom panującego w nim ciśnienia. Na podstawie znanych temperatur na powierzchni zewnętrznej ścianki walczaka rozwiązano zagadnienie odwrotne przewodzenia ciepła i wyznaczono pole temperatury w przekroju poprzecznym. Dla znanych obciążeń termicznych i ciśnieniem wyznaczono stan naprężenia w przekroju poprzecznym walczaka: maksymalne naprężenie zredukowane liczone według hipotezy HMH oraz maksymalne wartości składowych naprężenia: obwodowej, osiowej i promieniowej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.