Verification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5-20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits with RCDs usually use an extremely low value of current (lower than 15 mA), which in many cases it is not acceptable in terms of the measurement accuracy. This paper presents a method of earth fault loop impedance measurement in 3-phase circuits, without nuisance tripping of RCDs – the concept of measurement, the meter structure and the experimental validation. The nuisance tripping is avoided in spite of the use of measuring current value many times higher than that of the rated residual current of RCDs. The main advantage of the proposed method is the possibility of creating values of measuring current in a very wide range, what is very important with regard to accuracy of the measurement.
2
Content available remote Selektywność pełna i częściowa wyłączników różnicowoprądowych
PL
W pracy przedstawiono nowe i kompleksowe podejście do doboru wyłączników różnicowoprądowych w instalacjach elektrycznych dla uzyskania pełnej lub częściowej selektywności ich działania. Stwierdzono, że podana w pracy selektywność uzależniona jest zarówno od typu wyłączników (zwłoczny, bezzwłoczny), prądów działa oraz ich charakterystyk czasowo-prądowych. W analizie warunków współpracy selektywnej uwzględnione zostały wymagania normy PN-HD 61008-1 w zakresie maksymalnych czasów wyłączania i minimalnych niezadziałania oraz niesinusoidalne prądy różnicowe.
EN
The paper presents a new and comprehensive approach to the selection of residual current devices in electrical installations in order to obtain full or partial selectivity of their operation. It was found that the given selectivity depends both on the type of circuit breakers (delayed, instantaneous), operating currents and their time-current characteristics. In the analysis of the conditions of selective cooperation, the requirements of the PN-HD 61008-1 standard in the range of maximum switch-off and minimum no tripping times as well as non-sinusoidal differential currents were taken into account.
PL
W artykule zostały przedstawione wyniki badań nagrzewania się połączenia stykowego szyn płaskich miedzianych podczas przepływu prądów zakłóceniowych. Badaniom zostały poddane styki bez ochrony oraz z ochroną typu EPS-98 przy różnych wartościach siły ich docisku. Wyniki badań dowodzą zasadności stosowania ww. ochrony.
EN
The article presents test results concerning the heating condition of flat copper bus bar joints during the flow of fault currents. Joints with and without EPS-98 protection have been tested at various values of contact force. The results justify the application of the above mentioned protection.
EN
The society require reliable power network, that provides electric energy. In this article the rule of operation and construction of the superconducting fault current limiter of transformer type, which can be used in the future to increase security power network was described. The influence of magnetic coupling factor on value of impedance limiting fault current was theoretically analysed.
PL
Społeczeństwo wymaga niezawodnej sieci energetycznej dostarczającej energię. W tym artykule opisano zasadę działania i budowę nadprzewodnikowych ograniczników prądu typu transformatorowego, które mogą być w przyszłości stosowane dla zwiększenia bezpieczeństwa sieci energetycznej. Przeanalizowano teoretycznie wpływ współczynnika sprzężenia magnetycznego na wartość impedancji ograniczającej prąd zwarcia.