Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  fault conditions
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Differential relay protection for prototype transformer
EN
This paper represents the differential protection relay that used to protect the prototype-Terco power transformer. Matlab/Simulink is used to simulate the protection system. The power differential protection algorithm has been simulated and tested on a 2KVA power transformer under different faults. During normal operating conditions, current will flow through all phase of the power transformer within predesigned values which are appropriate to these elements rating and the faults can be classified as the flow of a massive current. the results signify suitable completion.
PL
W artykule przedstawiono zabezpieczenie różnicowe, które jest używane do ochrony transformatora mocy prototypu Terco. Algorytm zabezpieczenia różnicowego mocy został zasymulowany i przetestowany na transformatorze mocy o mocy 2 kVA przy różnych uszkodzeniach. W normalnych warunkach pracy prąd przepływa przez wszystkie fazy transformatora mocy w ramach wstępnie zaprojektowanych wartości, które są odpowiednie dla tych elementów znamionowych, a zwarcia można sklasyfikować jako przepływ prądu o dużej wartości.
PL
Przedstawiono ocenę działania zabezpieczeń transformatorów kategorii II eksploatowanych w Oddziale Białystok w latach 2003–2013.
EN
The paper presents an assessment of operation of protections of category II transformers operated in Białystok division in 2003–2013.
3
Content available remote Dynamic Performance of Line Commutated Converter-Based Multiterminal HVDC Systems
EN
In this article, the modelling and simulation results related to the dynamic performance of a multiterminal HVDC system, based on Line Commutated Converters (LCC), is presented. The four-converter HVDC system simulated operates at 500 kV. In order to evaluate its behaviour in a more realistic way, the multiterminal HVDC system was embedded into an equivalent ac network that resembles an existing high voltage system. A model to represent the ac generator dynamics (speed regulator and voltage controller), which interacts with the DC system, is also presented in the paper. The converter blocking condition, which is another HVDC operative requirement, was also simulated. From the dynamic response of the converters and ac sources obtained, it can be stated that the LCC-based multiterminal HVDC system can be a good alternative to be considered while analysing issues like planning, expansion and transmission of bulk power.
PL
W artykule zaprezentowano modelowanie i symulację właściwości dynamicznych systemu HVDC bazującego na układzie Line Commutated Converter LCC. W celu oceny właściwości w bardziej realistycvznych warunkach system HVDC został wbudowany w odpowiednią sieć AC co przypomina istniejące systemy wysokiego napięcia. Na podstawie badań stwierdzono że wieloterminalowy system HVDC może być dobra alternatywą dla istniejących systemów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.