1
Content available remote Causes of imminent failure damage and repair of steel building purlins
EN
A systemic design of purlins made from Z-sections (cold-formed from sheet metal) and their ties (made from solid bars) had been adopted in the investigated steel building. A periodic survey of the latter's technical condition showed that the purlins were deformed, bent and twisted and the ties were buckled. The condition of the roof deck supporting structure posed an imminent failure hazard. This paper presents the results of investigations of the load-bearing capacity and rigidity of the roof deck supporting structure, the aim of which was to determine the causes of its imminent failure condition.
PL
W artykule przedstawiono szczególny przypadek awaryjnego stanu technicznego remontowanego żelbetowego komina przemysłowego wysokości 120 m, po 35 latach jego eksploatacji. Zaprezentowano wyniki badań, na podstawie których podjęto decyzję o rozbiórce komina.
EN
This article describes the special case of the hazardous technical condition of a 120-metre-high reinforced concrete industrial chimney undergoing repair after 35 years of use. It presents the results of tests which led to a decision to demolish the chimney.
PL
W okresie ostatnich 40 lat wybudowano w Polsce kilkaset kominów żelbetowych cylindrycznych w technologii tzw. podwójnego ślizgu. Od początku kominy o tej konstrukcji wykazywały wady technologiczne i konstrukcyjne, które miały istotny wpływ na powstawanie uszkodzeń i występowanie awarii przewodów żarobetonowych, wbudowanych koncentrycznie wewnątrz trzonów tych kominów. Ze względu na zagrożenie bezpieczeństwa konstrukcji i utratę właściwości użytkowych, dużą część tych kominów wyłączono z eksploatacji. W pracy zbadano i przeanalizowano kilka eksploatowanych kominów tego typu, które uległy awarii bądź pozostawały w stanie zagrożenia awaryjnego w ostatnich kilkunastu latach. Przedstawiono program utrzymania tych obiektów, zapewniający ich dalszą warunkową eksploatację.
EN
In the recent 40 years several hundreds of cylindrical RC chimneys have been erected in Poland. These chimneys consist of two coaxial cylinders cast in tandem: the RC shaft and the heat-resisting liner. Both cylinders are separated by an air gap or by insulation. From the very beginning, the behavior of chimneys under consideration manifested itself by the occurrence of damage and failures of heat-resisting liners. For these reasons many of them are now out of operation. In the present paper, several cylindrical chimneys in operation have been examined and analyzed due to failure or failure warning that occurred in the last few years. The maintenance program for these chimneys has been proposed to ensure their further exploitation.
4
Content available Rozbiórka żelbetowego komina zbieżnego. Cz.2
PL
Artykuł dotyczy problemów, które pojawiać się będą coraz częściej w naszej praktyce, gdyż w latach sześćdziesiątych i siedemdziesiątych ubiegłego stulecia zrealizowano wyjątkowo dużo różnego rodzaju kominów przemysłowych. Dzisiaj są one często w złym stanie technicznym i zachodzi potrzeba ich modernizacji lub nierzadko potrzeba wyburzenia. W poprzednim numerze czasopisma (PB 9/2009) autor podzielił się z Czytelnikami swoimi spostrzeżeniami z realizacji rozbiórki komina H=140 m i wykonania na istniejącym fundamencie innego komina H=130 m w technologii ślizgowej. W związku ze zmianą parametrów komina - głównie średnicy trzonu - projektant zdecydował się posadowić trzon w wewnętrznej części cokołowej fundamentu z zastosowaniem prętów wklejanych w bryłę fundamentu.
EN
This paper concerns issues which will arise more and more often in practice, because in the 1960s and 1970s an exceptionally large number of industrial chimneys of various types were built. Today these are often in poor technical condition and require modernization or, quite frequently, demolition. In a previous issue (PB 9/2009) the author presented his observations concerning the demolition of a 140-metre chimney and the building on the existing foundations of another 130-metre chimney using a sliding technology. With regard to the change in parameters of the chimney - particularly the shaft diameter - the architect decided to base the shaft within the inner pedestal part of the foundation, using rods glued into the foundation block.