Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 22

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  evaporative cooling
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The article presents a simple prototype system based on the concept of indirect regenerative evaporative cooling (IREC) thermodynamic cycle for electronics applications. The key problem of selecting porous capillary material is discussed and preliminary experimental results are presented using IR thermography. The presented research is an initial step towards the development of a laboratory-validated, fully operational IREC system for high-power electronics.
PL
W artykule przedstawiono prototypowy układ chłodzenia oparty na koncepcji cyklu termodynamicznego pośredniego regeneracyjnego chłodzenia wyparnego (IREC) do zastosowań w elektronice. Omówiono kluczowy problem doboru porowatego materiału kapilarnego i przedstawiono wstępne wyniki eksperymentów z wykorzystaniem termografii w podczerwieni. Przedstawione badania stanowią wstępny krok w kierunku opracowania zweryfikowanego laboratoryjnie, w pełni funkcjonalnego systemu IREC do odprowadzania ciepła w systemach elektronicznych dużej mocy.
EN
In this paper, the possibility of use of a DEC type air conditioning system, using solar energy, in Polish climatic conditions Polish, as an alternative to traditional systems based on compressor refrigeration equipment, was analyzed. At the beginning of the work, attention was paid to how important it is for users to maintain thermal comfort conditions and how these conditions can be determined. It also shows why the DEC system can be a good solution for the cases under consideration. In the next part of the paper, the analyzed system is described, presenting the individual processes of humid air transformation taking place in it, in which devices these processes can take place and how they were modeled in further calculations. Modeling the operation of the DEC system was based mainly on determining the efficiency of individual devices, i.e. the effectiveness of the processes taking place in them and the use of a psychometric graph. Similarly, the method of calculating the useful heat that can be obtained from solar collectors under known conditions is presented. For this purpose, meteorological data and the theory of similarity in heat transfer were used. In the next part of the work, an example of a calculation cycle was presented, along with the next steps of applying to the psychometric graph points corresponding to the states of moist air at individual points of the DEC system. On the basis of such calculation cycles, performed for different values of outdoor air parameters, the relationships of the obtained cooling power, the power supplied for adsorber regeneration, EER, temperature and relative humidity of the supply air to rooms, from the temperature and relative humidity of the outside air. Next, the calculation process for determining the useful heat obtained from solar collectors is presented. On the basis of several such processes, the average conditions of heat collection from the collector were determined, on the basis of which the amount of energy obtained from solar radiation was determined on the scale of the entire summer period. On the basis of this analysis, surpluses and shortages of energy obtained from collectors on individual days of the considered period were determined. In conclusion, it was stated that despite the fairly good cooperation of the system with solar collectors and its simple construction, the DEC system cannot be an alternative to compressor refrigeration equipment. This is mainly due to the unfavorable level of relative humidity in Polish climatic conditions, which does not allow the device to achieve the appropriate temperature of the air supplied to the rooms.
PL
Obecnie poszukuje się alternatywnych rozwiązań tradycyjnych systemów klimatyzacyjnych, które pozwalają na obniżenie zużycia energii w budynkach. W niniejszym artykule przedstawiono postęp w opracowaniu prototypu wysokoefektywnej jednostki wentylacyjno-klimatyzacyjnej dla umiarkowanego i wilgotnego klimatu, wykorzystującej koncepcję wymienników wyparnych z tzw. chłodzeniem punktu rosy. Jest to możliwe dzięki technologii chłodzenia wyparnego stosowanego do zwiększenia efektywności osuszania powietrza. W celu zaprojektowania odpowiedniego urządzenia przeprowadzono szereg testów materiałów porowatych, które są wykorzystane do budowy wymiennika. Koncepcja została zweryfikowana z wykorzystaniem metod modelowania numerycznego oraz przeprowadzono wstępne badania eksperymentalne, które potwierdziły słuszność założeń. Jednostka może być również wykorzystana jako element dodatkowy w systemach klimatyzacyjnych obniżający zużycie energii elektrycznej przez sprężarkowe systemy chłodnicze.
EN
Currently, alternative solutions to traditional air-conditioning systems that reduce energy consumption in buildings are being searched for. This paper presents the progress in the development of a prototype of a highly efficient ventilation and air conditioning unit for moderate and humid climate, based on the concept of evaporative exchangers from the so-called dew point cooling. This is possible due to dedicated, evaporative cooling technology used to increase the efficiency of air dehumidification. In order to design a suitable device, a number of tests of porous materials were carried out, which are used to build the evaporative cooler. The concept was verified with the use of numerical modeling methods and preliminary experimental studies were carried out, which confirmed the correctness of the assumptions. The unit can also be used as an accessory for air conditioning systems to reduce the electricity consumption of compressor refrigeration systems.
EN
Performance analysis of a 1.0 tonne desiccant evaporative cooling storage structure for mango fruits was studied. The study examined the effects of inlet air conditions and water flow rates through an absorber on the cooling performance of the system. The airflow rate was approximately 0.24 m3·s -1 and water flow rates through the absorber varied from 0 to 0.252 l·s -1 . The system produced approximately 7 kW of cooling at water supply rate of 0.252 l·s -1. A simple linear correlation was established for condition line slope from inlet to exiting air conditions for all the water flow rates. Lines of best fit resulted in correlation coefficient better than 0.96. The observed temperatures with a direct evaporative cooler, tested with freshly harvested mango fruits were found to be between 15.1°C and 23.4°C and relative humidity between 81.8% and 97.7%. Physiological weight loss and firmness assessments of the fruits were also conducted.
PL
Artykuł omawia analizę wydajności chłodni wyparnej o poj. 1,0 tony, wykorzystywanej do przechowywania owoców mango. Zbadano wpływ warunków wlotowych powietrza i szybkości przepływu wody przez pochłaniacz na wydajność chłodniczą systemu. Natężenie przepływu powietrza wynosiło około 0,24 m3·s-1 , a natężenie przepływu wody przez absorber wahało się od 0 do 0,252 l·s-1 . W tym czasie wyprodukowano około 7 kW chłodu przy przepływie wody wynoszącym 0,252 l·s -1 . Określono prostą korelację liniową nachylenia linii wykresu warunków, od wlotu do wylotu powietrza, dla wszystkich wielkości przepływu wody. Linie o najlepszym dopasowaniu dały współczynnik korelacji powyżej 0,96. Zaobserwowane temperatury chłodni wyparnej, sprawdzane na świeżo zebranych owocach mango, wynosiły od 15,1°C do 23,4°C, a wilgotność względna od 81,8% do 97,7 %. Dokonano również oceny fizjologicznej utraty masy i jędrności owoców.
PL
W artykule omówiono możliwości obniżenia zużycia energii na potrzeby klimatyzacji w okresie letnim. Realizowane jest to poprzez zastosowanie pośredniego systemu wyparnego połączonego z wymiennikiem rekuperacyjnym do odzysku ciepła. Pracę tego układu porównano z typowym rekuperatorem przeciwprądowym. Przedstawiono również różne aranżacje systemów wyparnych: układ nawiewny, nawiewno-wywiewny oraz układ z wykorzystaniem recyrkulacji.
EN
Energy-saving trends cause a reąuirement to reduce cooling energy consumption during summer season. In order to fulfill these requirements indirect evaporative cooling system may be implemented for heat recovery which does not decrease the heat recovery efficiency during winter season.
PL
W artykule przedstawiono przyjazne środowisku alternatywne systemy chłodnicze, stosowane w klimatyzacji i badane w literaturze światowej. Omówiono różne warianty układów sorpcyjnych oraz wyjaśniono zjawiska zachodzące w bezpośrednich i pośrednich urządzeniach wyparnych, ze szczególnym uwzględnieniem wymienników wyparnych z obiegiem Maisotsenki. Porównano również pracę typowego układu sorpcyjnego wykorzystującego komory zraszania z układem współpracującym z wymiennikiem pośrednim wyparnym. Źródłem ciepła w obu analizowanych przypadkach jest układ solarny. Zastosowanie typowego układu wymaga większego osuszenia strumienia powietrza w rotorze sorpcyjnym, co znacznie zwiększa jego koszty eksploatacyjne w porównaniu do systemu sorpcyjnego bazującego na pośrednim chłodzeniu wyparnym.
EN
In this paper alternative environmental friendly cooling systems used in air conditioning are referred. Based on literature review different arrangements of solid desiccant systems are presented. This study explains also the idea of direct and indirect evaporative cooling, with special focus on the particular indirect evaporative cooling type which is known as the Maisotsenko-Cycle. In the presented comparison, typical Solar Assisted Solid Desiccant System (with direct evaporative coolers) needs higher dehumidification rate to reach the same supply air parameters than system with the counter-flow indirect evaporative cooler.
PL
Zaletą zastosowania wież chłodniczych w instalacjach klimatyzacyjnych jest obniżenie kosztów związanych z bezpośrednim zużyciem energii przez wentylatory osiowe skraplaczy chłodzonych powietrzem oraz pośrednio przez pompy obiegowe. W konsekwencji pozwala to na wydłużenie pracy sprężarkowych urządzeń chłodniczych, których skraplacz ochładzany jest przez płyn przygotowany w procesie chłodzenia w wieży chłodniczej. Praca takich wież może dawać bardzo dobre rezultaty, jednak pod warunkiem, że są one prawidłowo zaprojektowane i eksploatowane. Nawet drobne uchybienia w projekcie a przede wszystkim wykonaniu i eksploatacji wieży chłodniczej mogą wpływać na ich niewłaściwą pracę, zwiększenie kosztów ich eksploatacji i serwisowania. Dotyczy to szczególnie wież chłodniczych otwartych, w których schładzanie czynnika chłodniczego następuje przez bezpośredni kontakt z powietrzem. W przypadku nieprawidłowego podłączenia przewodu powrotnego lub zasilającego do wieży chłodniczej częstym zjawiskiem jest powtarzające się zapowietrzanie instalacji oraz przepływy wsteczne. W artykule wykazano istnienie przepływów wstecznych w instalacji wieży chłodniczej pracującej w jednym z obiektów we Wrocławiu.
EN
The advantage of using cooling towers in air-conditioning systems is to reduce the energy costs associated with direct energy consumption by fans and indirectly by circulating pumps. As a consequence, it allows to extend the work of the compressor of the refrigeration equipment, whose condenser is cooled by the liquid prepared in the cooling process in the cooling tower. The work of such towers can produce very good results, but only if it is properly designed and operated. Even minor deficiencies in the execution of the cooling towers, especially those with an open air flow, can increase the costs of their operation and servicing. In the event of incorrect connection of the return or supply line of water in the cooling tower, it is common for the system to return aeration and back flows. In this article, it is exhibited the existence of backflows in the installation of a cooling tower operating in one of the buildings in Wrocław.
PL
Sorpcyjno-wyparne systemy chłodzenia DEC (ang. desiccant evaporation cooling) stanowią alternatywę dla klasycznych systemów klimatyzacji wykorzystujących sprężarkowe urządzenia chłodnicze. Stosowanie systemów DEC pozwala na obniżenie zużycia energii elektrycznej przez systemy klimatyzacyjne nie pogorszając przy tym jakości powietrza dostarczanego do pomieszczeń. Nie wykorzystują przy tym „freonowych” czynników chłodniczych, dzięki czemu nie mają negatywnego wpływu na środowisko. W technologii DEC powietrze chłodzone jest poprzez odparowanie wody, aby zwiększyć efekt chłodzenia powietrze wstępnie jest osuszone przy zastosowaniu stałych, bądź ciekłych sorbentów. Do regeneracji sorbentów, wymagają dostarczenia ciepła o temperaturze w zakresie 50 – 100˚C. Ze względu na możliwość wykorzystania odpadowych i odnawialnych źródeł ciepła technologia DEC stanowi interesujące rozwiązanie. W artykule opisano zasadę działania systemu DEC, oraz przedstawiono wyniki obliczeń dla systemu pracującego w warunkach letnich w klimacie umiarkowanym. Obliczenia wykonane zostały przy założeniu temperatury powietrza zewnętrznego równej 27°C, wilgotność względną przyjmowano z przedziału 45 – 80% zmieniając tę wartość co 5%. Do analizy przyjęto stałe zyski ciepła jawnego i utajonego wewnątrz przestrzeni klimatyzowanej, które wynoszą odpowiednio 15 kW i 3 kW. Strumień powietrza wentylacyjnego przyjęto na poziomie 1000 __⁄ℎ. Wyniki obliczeń pokazują, że w zakresie wilgotności względnej powietrza zewnętrznego poniżej 60 % systemy DEC są w stanie zapewnić odpowiednią jakość powietrza wentylacyjnego, oraz odebrać zyski ciepła i wilgoci z pomieszczeń klimatyzowanych. Wybrany sorbent, do regeneracji wymaga dostarczenia strumienia ciepła o temperaturze około 70°C, w ilości trzykrotnie większej w stosunku do strumienia ciepła jaki jest do odebrania z pomieszczeń.
EN
Desiccant evaporation cooling systems (DEC) are an alternative to conventional vaporcompression cooling units. The use of DEC systems reduces the electricity consumption of air conditioning systems and do not deteriorating the quality of supplied air at the same time. They do not use refrigerants, so do not have a negative impact on the environment. In DEC technology cooling effect is achived by evaporation of water. To increase the cooling effect first the air is dehumidified by a solid or liquid sorbent. Regeneration of sorbents requires the input of heat at a temperature in the range of 50 - 100 ° C. Due to the possibility of using waste, or renewable heat the DEC technology is an interesting solution. This paper describes the principle of operation of the DEC, and showing the influence of some operating parameters for a system efficiency. Calculations were made with the assumption of an outdoor air temperature at the 27 ° C, relative humidity was taken between 45 - 80% by changing the value by 5%. For the analysis a sensible and latent heat gains inside the conditioned space were assumed, respectively 15 kW and 3 kW. Ventilation air flow is assumed to be 1000 __/ℎ. The calculation results show that for the relative humidity of the outside air below 60% DEC systems are able to ensure the required quality of ventilation air, and take of the heat and moisture gains from the air-conditioned space. The selected sorbent regeneration requires the heat flux at a temperature of about 70 ° C, in an amount three times as compared to the heat flow taken from the air conditioned space.
PL
W artykule przeanalizowano możliwości techniczne zastosowania systemu chłodzenia wyparnego do klimatyzacji wielkopowierzchniowych obiektów handlowych w warunkach klimatu środkowo europejskiego. Szczegółowej ocenie poddano jedną z wielu wersji systemu w postaci bezpośredniego chłodzenia/nawilżania adiabatycznego z osuszaniem sorpcyjnym (Desiccative Evaporative Cooling System) i regeneracją wilgoci za pomocą ciepła odpadowego o niskiej egzergii. Do tej grupy zaliczono ciepło systemowe dostępne w miejskich sieciach ciepłowniczych, a powstające jako produkt uboczny pracy elektrociepłowni. Obliczenia dotyczyły obiektu zlokalizowanego w Krakowie przy czym wykorzystano produkty dostępne na rynku i charakterystyki dostarczone przez producentów. Proponowany system został porównany z tradycyjnym rozwiązaniem chłodzenia (za pomocą agregatu sprężarkowego ze skraplaczem chłodzonym powietrzem) w zakresie zapotrzebowania na energię końcową i pierwotną, emisji CO2 oraz kosztów, przy spełnieniu tych samych wymagań ilościowych i jakościowych obydwu systemów.
EN
The article analyses the technical capabilities of the application of evaporative cooling system to air conditioning of commercial buildings with big surface size in Central European climate conditions. Detailed assessment has been made on one of many versions of the system in the form of direct cooling/adiabatic humidification and adsorptive desiccation with moisture regeneration by using waste heat of low exergy. This group included heat system available in urban district heating networks, and emerging as a side effect in heat and power plants. Calculations have been made for an object located in Kraków, with the use of products available on the market, on the basis of the characteristics provided by the manufacturers. The system proposed has been compared with traditional cooling solution using a compressor unit with air-cooled condenser in terms of final and primary energy demand, CO2 emissions, and costs, subjected to the same qualitative and quantitative requirements for both systems.
PL
W pracy przedstawiono przykłady zastosowań chłodzenia wyparnego. Z literatury zaczerpnięto znane realizacje instalacji wykorzystujących chłodzenie wyparne. Przedstawiono koncepcję urządzenia opartą na wykorzystaniu istniejącego na rynku wymiennika do chłodzenia wyparnego powietrza. Porównano pracą instalacji w różnych strefach klimatycznych. Odniesiono metodę wyparną do klasycznej, sprężarkowej, ukazując jakie korzyści finansowe może nieść za sobą wybór alternatywnej metody chłodzenia powietrza.
EN
The following paper presents examples of evaporative cooling applications. Known examples of such implementations have been collected from literature. The paper also includes a device concept, based on the use of the commercially available evaporative air cooling heat exchanger. A comparison of plant operation in different climatic zones has also been involved. The evaporative method has been confronted with the conventional, compressor-based one, showing financial benefits of choosing the alternative air cooling method.
PL
W pracy przedstawiono podstawy termodynamiczne chłodzenia wyparnego. Omówiono cztery sposoby realizacji takiego procesu, tj. poprzez chłodzenie bezpośrednie, pośrednie, metodę hybrydową (pośrednią/bezpośrednią) oraz metodą mieszaną, która łączy chłodzenie wyparne z tradycyjnymi metodami sprężarkowymi. Przedstawiono rozważania związane z zapotrzebowaniem na wodę dla poszczególnych rodzajów chłodzenia, jak również oszacowano skutki ekologiczne zastosowania urządzeń wyparnych, wykazując w ten sposób korzystne efekty środowiskowe wynikające z zastosowania tego rozwiązania.
EN
In the paper presented have been thermodynamic foundations of evaporative cooling. There have been discussed four ways of realization of such process, i.e. by direct cooling, indirect cooling, hybrid method (direct/indirect) and the mixed method, which combines evaporative cooling with traditional compressor-based systems. There have been also presented considerations related to demand for water for specific evaporative systems as well as the ecological consequences of application of such systems have been pointed out proving the positive environmental effects stemming from use of these systems.
PL
W artykule opisano wyniki dwumiesięcznych pomiarów parametrów pracy urządzenia do bezpośredniego chłodzenia wyparnego (adiabatycznego, ewaporacyjnego) budynku. Na podstawie tych wyników wykonano obliczenia dla typowych letnich parametrów klimatycznych w czterech miastach Polski. Chłodzenie wyparne jest interesującą alternatywą dla dominujących na rynku sprężarkowych urządzeń chłodniczych. Dziesięciokrotnie wyższa efektywność energetyczna oraz brak negatywnego oddziaływania na środowisko to podstawowe atuty tego systemu. Decydując się na zastosowanie chłodzenia wyparnego, należy jednak wziąć pod uwagę, że w przypadku okresowej wysokiej wilgotności powietrza zewnętrznego odczuwalna moc chłodnicza zastosowanego urządzenia będzie znacznie mniejsza. Ponadto można się spodziewać trochę zwiększonej wilgotności względnej powietrza w chłodzonych pomieszczeniach. Przy prawidłowej eksploatacji urządzenia zagrożenie rozwojem bakterii Legionella pneumophila jest znikome lub w ogóle nie występuje.
EN
This paper contains results of two-months measurements of operational parameters of direct evaporative cooling unit. Based on the results of the measurements, calculations of seasonal average operational parameters for typical summer climate parameters for four Polish cities were performed. Evaporative cooling is an interesting alternative to refrigeration-based cooling systems. Ten times higher energy efficiency, and no negative impact on the environment are key advantages of this system.
PL
W artykule przedstawiono analizę zmodyfikowanego wymiennika przeciwprądowego, wykorzystującego obieg Maisotsenki. W poprzedniej części tekstu został przedstawiony oryginalny model opisujący procesy zachodzące w omawianym wymienniku. Na podstawie modelu, w niniejszym tekście zaprezentowano wyniki obliczeń, które obrazują pracę omawianej jednostki wyparnej w wybranych warunkach klimatycznych.
EN
This paper presents an analysis of the modified counter-flow heat exchanger, using Maisotsenko cycle. Tests were conducted using original e-NTU-model and the program based on the original code and algorithms. The presented results of calculations show the exchangers per formance under various climate conditions.
14
Content available Evaporative roof cooling - economy
EN
The article presents information on research on evaporative cooling system for large surfaces conducted by the company Öntözés.hu Ltd in cooperation with the Budapest University of Technology and Economics. It enumerates advantages of employing such solutions on roofs.
PL
W artykule przedstawiono informację na temat badań prowadzonych nad wyparnym systemem chłodzenia dla dużych powierzchni przez firmę Öntözés.hu Ltd we współpracy z Uniwersytetem Politechnicznym w Budapeszcie. Omówiono korzyści płynące z zastosowania tego rodzaju rozwiązań na dachach.
PL
W pracy dokonano analizy możliwości wykorzystania płytowych wymienników ciepła w przemysłowej instalacji chłodzenia wyparnego powietrza. Przedstawiono wybrane elementy algorytmu obliczeń numerycznych wraz z wynikami dla warunków prowadzonych badań doświadczalnych. Dokonano porównania wyników badań z wartościami obliczonymi i wykazano ich dużą zgodność. Omówiono warunki eksploatacji instalacji oraz wskazano na możliwość jej optymalizacji.
EN
Analysis of possible use of plate heat exchangers in the industrial air evaporative cooling system is presented in the paper. The selected elements of numerical algorithm calculations with the results for conducted experimental research conditions are given. The comparison between experimental and calculated results was made showing a high accuracy. Exploitation conditions of the installation are discussed and possibility of its optimization is indicated.
16
Content available remote Klimatyzacja pasywna i wyparna
PL
W artykule przedstawiono zagadnienia związane z metodami pasywnego (bez dostarczania energii napędowej) wyparnego chłodzenia strumienia powietrza wykorzystywanego następnie do wentylacji /chłodzenia / klimatyzowania pomieszczeń. Niezbędne przepływy strumienia powietrza mogą być indukowane energią kinetyczną wiatru i wspomagane energią promieniowania słonecznego, zaś schładzanie powietrza następuje w procesie jego nawilżania. Metody takie znane są od blisko 2500 lat, jednak rozwój sprężarkowych i absorpcyjnych urządzeń chłodniczych pomniejszył znaczenie pasywnych instalacji klimatyzacyjnych jako mało wydajnych. Obecnie, w następstwie rosnących cen energii i konieczności ochrony środowiska naturalnego, następuje stopniowy powrót do doświadczeń naszych przodków. Poza tradycyjnym chłodzeniem pomieszczeń, instalacje pasywne umożliwiają klimatyzację otwartych przestrzeni urbanistycznych, takich jak: ciągi uliczne, otwarte miejsca zgromadzeń publicznych itp.
EN
This paper discusses issues related to the methods of passive (without providing a driving power) evaporative cooling of air to be utilised for cooling / air-conditioning of living spaces. The necessary air stream flows can be induced by kinetic energy of wind sometimes assisted with a solar energy. Required air cooling is obtained in the process of its moisturizing. The first installations of this type appeared close to 2,500 years ago. Now, according to the growing energy prices and the needs for the protection of the environment, a gradual return to the experience of our ancestors occurs. In addition to the traditional cooling tasks, passive systems allow air conditioning of urban spaces such as: street sequences, open space public meeting places etc.
17
Content available remote Analiza numeryczna zużycia wody przez pośrednie wymienniki wyparne
PL
W artykule przedstawiono zależność zużycia wody przez ekologiczne instalacje klimatyzacyjne oparte na wymiennikach wyparnych. Opisano matematyczne ε−NTU−modele nieliniowych procesów wymiany ciepła i masy w ożebrowanych wymiennikach wykorzystując różne schematy przepływu. Otrzymano wyniki obrazujące zależność zużycia wody od różnych parametrów wejściowych oraz w odniesieniu do efektywności chłodniczej urządzeń. Uzyskane wyniki umożliwiają oszacowanie optymalnych schematów przepływu powietrza.
EN
In this paper, the dependence of the water consumption of ecological air conditioning systems based on evaporative heat exchangers has been shown. Mathematical models of nonlinear processes of heat and mass in a finned heat exchangers using various flow diagrams has been described. The results illustrating the dependence of water consumption of the various input parameters and for the efficiency of the cooling devices have been shown. The results obtained make it possible to estimate the optimal flow patterns.
PL
W artykule scharakteryzowano pośrednie i bezpośrednie ochładzanie powietrza. Przedstawiono kierunki rozwoju pośrednich jednostek wyparnych w oparciu o wielokryteriową optymalizację procesów wymiany ciepła i masy w kanałach wypełnienia.
EN
The paper describes direct and indirect evaporative air cooling. The basic trends of indirect evaporative units improvement, based of multi-criteria optimization of heat and mass transfer processes have been shown.
19
Content available remote Impact of inlet air cooling on gas turbine performance
EN
In this article different possibilities of gas turbine inlet air cooling were presented. The method of defining power gain caused by air cooling was discussed. The results of increasing power output level of several different turbines and one gas turbine in combine cycle in domestic ambient conditions were presented and discussed. Significant turbine power gains were received.
PL
W niniejszym artykule przeanalizowano kombinowane systemy klimatyzacyjno-odsalające oparte na pośrednich rekuperatorach wyparnych, wykorzystywane przez korporacje naftowe (m.in. Exxon Mobil) wydobywające ropę na terenie Afryki i Bliskiego Wschodu, gdzie woda jest towarem deficytowym. Porównano pracę systemów opartych na wymiennikach o różnych schematach przepływu powietrza (współprądowym, przeciwprądowym, regeneracyjnym i krzyżowym). Położono nacisk na zwiększenie efektywności odparowania cieczy będącej źródłem wody pitnej oraz na uzyskanie możliwie niskiej temperatury powietrza nawiewanego do klimatyzowanych pomieszczeń.
EN
This paper examines the combined air–conditioning and desalination systems based on indirect evaporative recuperators used by oil companies (including Exxon Mobil) extracting oil in Africa and the Middle East, where water is scarce. Systems based on exchangers with different schemes of air flow (cocurrent, countercurrent, regeneration and cross) have been compared. The focus was on increasing the effectiveness of evaporation of the liquid, which is a source of drinking water and getting as low supply air temperature to the air-conditioned rooms.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.