Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 21

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  envelope
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available remote Multi-scale envelope-based analysis of geomagnetic anomaly field
EN
This paper introduces a news processing method for geomagnetic anomaly field data: envelope mode magnetic field, which can weaken the influence caused by geomagnetic polarity reversal during rock magnetization, reflect the magnetic change of crustal rocks, and locate the crustal structures. According to the characteristics of the magnetic anomaly field, the envelope mode magnetic field is calculated in three different ways: full anomaly envelope, positive anomaly envelope, and negative anomaly envelope. The simulation test of seismic signal and magnetic anomaly model has achieved good results. During the calculation of the real-world data, because the magnetization directions of the geomagnetic field in the southern and northern hemispheres are opposite, we use the full envelope or positive envelope method for the northern hemisphere and the negative envelope method for the southern hemisphere. The experiment using EMAG2 global satellite magnetic anomaly data demonstrates that the strong anomaly of the envelope mode magnetic field is consistent with the spatial distribution of cratonic tectonic units, confirming its application effect.
EN
One of the best practical methods to machine the air compressor screw pairs is milling or grinding by disc tools. The mathematics involved in disc tool profiling is quite complex and requires representing the machined surface by mathematical equations without any singular points and undercutting. From a technical perspective, this article proposes the disc tool profiling integrated solution for machining complex profile screws from their reverse engineering data, which contains crucial issues such as machining deviation evaluation due to undercutting, appropriate tool position setting. The disc tool surface designed by the proposed method is highly accurate, leading the RMS error of the machined surface is less than 0.0201 mm. A difference of the angle, formed by the disc tool axis and the workpiece axis, less than 0.16°, is acceptable in air compressor technology, which leads to a machined surface RMS deviation of less than 0.0186 mm.
PL
Powszechne nazywanie modulacji liniowych nośnej sinusoidalnej modulacjami amplitudy nie jest uzasadnione, bowiem modulacji obwiedni zwykle towarzyszy modulacja kąta. Istnieją nawet przypadki, kiedy efektywnie modulowany jest tylko kąt. Rzeczywistą modulacją amplitudy jest wyłącznie modulacja AM. Przyczynami klasyfikacyjnych niedostatków są: historia wynalazków, nie dość konsekwentne interpretowanie pojęcia amplituda i niepostawienie pytania o efekt modulacji amplitudy, która powinna wytwarzać nośną zmodulowaną tylko w amplitudzie. Te dwie ostatnie przyczyny są szczegółowo rozważone w artykule, w którym także zasugerowano pewne zmiany w nazewnictwie. Ponadto w sytuacji specyficznego zakłócenia porównano odbiory homodynowy i heterodynowy. Zaproponowano sekwencję niektórych tematów prezentacji problematyki modulacji liniowych.
EN
Linear modulations of a sinusoidal carrier are usually described as amplitude modulations which is not a proper choice, since an envelope modulation is often accompanied by an angle modulation. There are even some cases, when only the angle is modulated effectively. The actual amplitude modulation is the modulation marked with an acronym AM. The classification and the naming misfits result from three reasons: history of inventions, a lack of a consequent interpretation of the term amplitude and not raising the question on an effect of the amplitude modulation which should produced amplitude only modulated carrier. The last two reasons are considered in the paper in detail. Some naming changes are suggested. Furthermore, for a specific interference the homodyne and the heterodyne receptions are compared. There is a proposal of a sequence of problems explaining concepts of linear modulations.
EN
This paper presents two methods to recognize authenticity of the postal envelopes sealing. These methods are: infrared thermography and thickness measurement. Additionally, microscope inspection is presented. Based on the results, quantitative assessment was developed. The proposed methods make it possible to recognize authenticity of the postal envelopes sealing.
EN
This paper presents a method of improvement of the accuracy in natural frequency determination when having impulse responses from impact testing. A new method is used for obtaining impulse response spectrum. The improvement in natural frequency determination is a result of improving the spectral resolution. For this, the new method uses calculation of surface area under the envelope of the cross-correlation function. This process is repeated by single-harmonic signal generated step-by-step with frequency changed iteratively. Thus the frequency resolution of determined spectrum is independent of length of analysed impulse response.
PL
Praca przedstawia sposób poprawy dokładności wyznaczania częstotliwości drgań własnych mając odpowiedzi z badań impulsowych. Nowej metody używa się w celu znalezienia widma odpowiedzi impulsowej. Poprawa wyznaczania częstotliwości drgań własnych jest wynikiem poprawy rozdzielczości widmowej. W tym celu nowa metoda wyznacza pole powierzchni pod obwiednią funkcji korelacji wzajemnej. Proces ten dokonuje się cyklicznie włącznie z generacją fali harmonicznej krok po kroku wraz z iteracyjną zmianą jej częstotliwości. W ten sposób, rozdzielczość częstotliwościowa wyznaczanego widma jest niezależna od długości analizowanej odpowiedzi impulsowej.
6
Content available remote Układ kształtowania obwiedni wzorcowego pola elektromagnetycznego
PL
W pracy przedstawiono koncepcję układu do kształtowania obwiedni modulowanego wzorcowego pola elektromagnetycznego (PEM). Dokonano analizy źródeł PEM, które emitują pole o charakterze znacznie odbiegającym od pola CW, zaprezentowano układ prototypowy oraz przeprowadzono jego weryfikację. Przedstawiono wstępne badania możliwości metrologicznych szerokopasmowych mierników PEM pod kątem pomiaru pola impulsowego o parametrach obwiedni odpowiadającej PEM emitowanym przez urządzenia radiolokacyjne (radary).
EN
Paper presents a concept of pulse modulated electromagnetic field (PEMF) envelope shaping system. Analysis of EMF sources with particular pulse envelopes is performed. Presented and verified a prototype circuit and also showed preliminary research on metrological possibilities of broadband electromagnetic field meters to measure PEMF with envelope parameters same as in radiolocation systems.
PL
W artykule omówiono zagadnienie wykorzystania termografii aktywnej w nieniszczących badaniach przegród budowlanych, w tym przebieg doświadczenia z wykorzystaniem termografii aktywnej w trybie odbiciowym. Wewnętrzne wtrącenia materiałowe w badanych modelach przegród zostały wykonane ze styropianu XPS, stali oraz granitu. Otrzymane wyniki opisano za pomocą bieżącego kontrastu temperaturowego. Artykuł prezentuje sposób wyznaczania głębokości położenia defektu w przegrodzie budowlanej za pomocą metody echo defect shape. Na podstawie wniosków z przeprowadzonego doświadczenia potwierdzono przydatność nieniszczących badań za pomocą termowizji aktywnej do detekcji głębokości defektów w przegrodach.
EN
The paper presents the problem of building envelope investigation with the use of active thermography. Examples of active thermography in the reflective mode application and a description of the experimental investigation has been shown on a wall model with the inclusion of materials with significantly different thermal conductivity and heat capacity, i.e. styrofoam, steel and granite. Article presents a method of determining the depth of the defect in the building envelope using the echo defect shape method. Finally, the summary and conclusion is shown along with the prospects of development of this kind of investigation in inclusions depth detection.
PL
W artykule przedstawiono wyniki obliczeń dotyczące zmiany wartości wskaźnika rocznego zapotrzebowania na nieodnawialną energię pierwotną (EP) z tytułu ograniczenia współczynników przenikania ciepła przegród budowlanych (U). Analizę przeprowadzono na przykładzie dwóch budynków wielorodzinnych niewyposażonych w instalację chłodzenia, o różnych współczynnikach kształtu. Rozpatrzono trzy przypadki dotyczące wymagań izolacyjności cieplnej przegród budowlanych zawartych w przepisach technicznych. Analizowane przypadki: pierwszy – budynki spełniające obecne wymagania, drugi – wymagania obowiązujące od 2017 r., trzeci – wymagania od 2021 r. Następnie w każdym przypadku rozpatrzono cztery warianty różniące się sprawnością systemu ogrzewania oraz sposobem produkcji dostarczanego ciepła. Obliczenia wykonano zgodnie z zasadami sporządzania charakterystyki energetycznej budynku zawartymi w przepisach krajowych. Uzyskane wartości EP porównano z wartościami maksymalnymi podanymi w przepisach techniczno-budowlanych. Z przeprowadzonej analizy wynika, że pomimo spełnienia wymagań dotyczących współczynnika przenikania ciepła przegród (U) i wysokiej sprawności systemów instalacyjnych nie zawsze możliwe jest spełnienie wymagań EP.
EN
This paper presents the results of calculations concerning changes in the rate of annual demand for nonrenewable primary energy (EP) due to limitations on heat transfer coefficients of building partitions (U). The analysis was conducted on the example of two multi-family buildings not equipped with a cooling system having different shapes. Three cases concerning the requirements of the thermal insulation of building partitions contained in the technical regulations were studied. Case studies: first – buildings that meet current requirements; second – the requirements in force since 2017; third – the requirements that will be in force since 2021. Then, for each of the cases four variants that differ in efficiency of the heating system and a method for producing heat input were examined. Calculations were made in accordance with the principles of drawing up the energy performance of the building compliant with the national legislation. EP obtained values were compared to the maximum values given in the technical and construction regulations. The analysis shows that despite fulfilling the requirements for U and high efficiency installation systemit is not always possible to meet the requirements for EP.
9
Content available remote Modelowanie strefy buforowej w domu jednorodzinnym
PL
Strefy buforowe, ze względu na zmniejszenie różnic temperatury po obu stronach przegród, powinny ograniczać straty ciepła w sezonie grzewczym oraz lepiej zabezpieczać budynek przed przegrzewaniem w lecie. Ich funkcjonowanie zależy jednak od wielu czynników, zarówno pogodowych, jak i właściwości samej strefy buforowej: jej wielkości i lokalizacji, szczelności przegród i wielkości przeszkleń. Opisane w artykule badania nad zasadnością stosowania stref buforowych polegały na kalibrowaniu modelu komputerowego, tak aby w wyniku symulacji otrzymać wartości temperatury w pomieszczeniach, zbliżone do zmierzonych. Pomiary prowadzone były w budynku jednorodzinnym, wykonanym w technologii szkieletu drewnianego, posiadającym kilka stref buforowych, takich jak oranżeria czy poddasze nieużytkowe. Wyniki badań wskazują na rzeczywiste zyski cieplne uzyskane dzięki strefie buforowej. Pomiary temperatury na zewnątrz i wewnątrz budynku pozwoliły również określić kierunki przepływu ciepła przez oranżerię. Docelowym efektem badań, których fragment opisuje artykuł, jest sprawdzenie, jak zmienia się zapotrzebowanie na energię użytkową do celów ogrzewania i wentylacji istniejącego budynku jednorodzinnego w zależności od zmiany parametrów jego stref buforowych. Badania te są kontynuacją analiz koncepcji „Domu w Domu”, będącego przykładem wykorzystania podwójnej fasady jako strefy buforowej.
EN
Buffer zones, due to reduced temperature fluctuations on both sides of partitions, should reduce heat loss during the heating season and provide better protection against overheating in summer. However, their operation depends on many factors – weather, size and location of the zone, partition airtightness and glazing proportions. The research on buffer zones and justness of their use in Polish climate, presented in this article, consists of the computer model calibration, which aimed to achieve similar simulated temperatures to the measured values in particular zones. The existing building, in which measurements were conducted, is a single-family house with a wooden frame construction. It has several buffer zones: sunspace, unheated attic and garage. The results show the actual heat gains obtained through the buffer zone. Temperature measurements inside and outside the building also enabled determining the direction of heat flow through the sunspace. The long-range scope of the research, which fragment is described in this article, is to check the relationship between parameters of the buffer zone and energy demand of a single family house. These studies are a continuation of analyses of the Double Skin House concept, which is an example of the use of the double façade as a buffer zone.
PL
W artykule przedstawiono wyniki badań eksperymentalnych przegród zawierających materiały fazowo zmienne (PCM). Przedmiotem badań było jednoczesne zastosowanie dwóch rodzajów PCM: płyt gipsowo-kartonowych zawierających kapsułki z parafiną o temperaturze przemiany 23 °C oraz elastycznych mat wypełnionych materiałem organicznym o temperaturze przemiany 25 °C. Badania przeprowadzono w komorze klimatycznej. Analizowano pomiary przebiegu temperatury oraz rozkładu gęstości strumieni cieplnych na powierzchniach płyt w zmiennych warunkach panujących w komorze klimatycznej.
EN
The article presents results of experimental studies on component containing phase change materials (PCM). The subject of research was the simultaneous usage of two different PCM materials: gypsum-carton boards with paraffin capsules of change temperature 23 °C and the flexible mat filled with organic material of change temperature 25 °C. The tests were carried out in a climatic chamber. Measurements of temperature course were taken as well as heat flux density distribution on the surfaces of boards for variable conditions in the climatic chamber.
PL
Omówiono wyniki analiz dotyczących wpływu kształtu budynku mieszkalnego na jego bilans energetyczny. Do oceny wybrano trzy domy jednorodzinne o zbliżonej powierzchni użytkowej i konstrukcji przegród, różniące się współczynnikiem kształtu. Stwierdzono, że wpływ ukształtowania bryły budynku na straty ciepła przez przenikanie jest znaczący.
EN
In this paper the results of the influence of the form of the residential building on its energy balance were presented. For the analyses three detached houses with similar surface and structure of partitions but with different shape coefficients were chosen. The calculations for these three chosen buildings characterized by different shapes indicate that the influence of this factor is significant to heat losses through transmission.
EN
In this work, we present a novel Hilbert-twin method to compute an envelope and the logarithmic decrement, δ, from exponentially damped time-invariant harmonic strain signals embedded in noise. The results obtained from five computing methods: (1) the parametric OMI (Optimization in Multiple Intervals) method, two interpolated discrete Fourier transform-based (IpDFT) methods: (2) the Yoshida-Magalas (YM) method and (3) the classic Yoshida (Y) method, (4) the novel Hilbert-twin (H-twin) method based on the Hilbert transform, and (5) the conventional Hilbert transform (HT) method are analyzed and compared. The fundamental feature of the Hilbert-twin method is the efficient elimination of intrinsic asymmetrical oscillations of the envelope, aHT (t), obtained from the discrete Hilbert transform of analyzed signals. Excellent performance in estimation of the logarithmic decrement from the Hilbert-twin method is comparable to that of the OMI and YM for the low- and high-damping levels. The Hilbert-twin method proved to be robust and effective in computing the logarithmic decrement and the resonant frequency of exponentially damped free decaying signals embedded in experimental noise. The Hilbert-twin method is also appropriate to detect nonlinearities in mechanical loss measurements of metals and alloys.
PL
W pracy przedstawiono nową metodę Hilbert-twin, opartą na dyskretnej transformacie Hilberta, do obliczeń obwiedni wykładniczo tłumionych sygnałów odkształceń sprężystych zawierających w sobie szum oraz do estymacji logarytmicznego dekrementu tłumienia. Przeanalizowano i porównano wyniki obliczeń uzyskane z pięciu różnych metod: (1) metoda parametryczna OMI (Optimization in Multiple Intervals), dwie metody bazujące na interpolowanej dyskretnej transformacie Fouriera (IpDFT): (2) metoda Yoshida-Magalas (YM) i (3) klasyczna metoda Yoshidy (Y), (4) nowa metoda Hilbert-twin (H-twin), którą po raz pierwszy przedstawiono w niniejszej pracy oraz (5) klasyczna metoda obliczeń obwiedni z transformaty Hilberta (HT). Zaletą i fundamentalną cechą charakterystyczną metody H-twin jest skuteczne usunięcie typowych dla dyskretnej transformaty Hilberta asymetrycznych oscylacji obwiedni. Z tego właśnie względu metoda H-twin zapewnia bardzo dobrą estymację logarytmicznego dekrementu tłumienia, która jest porównywalna z metodami OMI i YM zarówno dla niskich, jak i wysokich poziomów tłumienia. Metoda H-twin jest niewrażliwa na szum i jest wyjątkowo skuteczna w precyzyjnym wyznaczaniu logarytmicznego dekrementu tłumienia oraz częstotliwości rezonansowej wykładniczo tłumionych drgań swobodnie tłumionych zawierających szum eksperymentalny. Metoda H-twin może również służyć do detekcji i analizy efektów nieliniowych występujących w trakcie pomiarów rozpraszania energii mechanicznej w metalach i stopach metali badanych metodą spektroskopii mechanicznej.
EN
The parametric OMI (Optimization in Multiple Intervals), the Yoshida-Magalas (YM) and a novel Hilbert-twin (H-twin) methods are advocated for computing the logarithmic decrement in the field of internal friction and mechanical spectroscopy of solids. It is shown that dispersion in experimental points results mainly from the selection of the computing methods, the number of oscillations, and noise. It is demonstrated that conventional Hilbert transform method suffers from high dispersion in internal friction values. It is unequivocally demonstrated that the Hilbert-twin method, which yields a ‘true envelope’ for exponentially damped harmonic oscillations is superior to conventional Hilbert transform method. The ‘true envelope’ of free decaying strain signals calculated from the Hilbert-twin method yields excellent estimation of the logarithmic decrement in metals, alloys, and solids.
PL
Do estymacji logarytmicznego dekrementu tłumienia w spektroskopii mechanicznej i w badaniach tarcia wewnętrznego ciał stałych zarekomendowano w pracy następujące metody obliczeniowe: metodę parametryczną OMI (Optimization in Multiple Intervals), metodę Yoshida-Magalas (YM) i nową metodę Hilbert-twin (H-twin). Wykazano, że dyspersja punktów eksperymentalnych logarytmicznego dekrementu tłumienia i tarcia wewnętrznego zdeterminowana jest przede wszystkim wyborem metody obliczeniowej, liczbą oscylacji i obecnością szumu w dyskretnych sygnałach odkształceń sprężystych badanych materiałów. Zastosowanie do obliczeń logarytmicznego dekrementu tłumienia klasycznej transformaty Hilberta powoduje bardzo dużą dyspersję punktów eksperymentalnych. W pracy wykazano, że metoda Hilbert-twin (transformata Hilberta zbliźniakowanego dyskretnego sygnału odkształceń sprężystych) po raz pierwszy umożliwia uzyskanie „prawdziwej obwiedni” wykładniczo tłumionych drgań harmonicznych próbki. Nowa metoda obliczeń „prawdziwej obwiedni” umożliwia bardzo dokładną estymację logarytmicznego dekrementu tłumienia w materiałach metalicznych i w ciałach stałych.
14
Content available remote Pojemność cieplna a komfort termiczny w budynkach energooszczędnych
PL
Ograniczanie zużycia energii w budownictwie energooszczędnym przy jednocześnie wysokich wymaganiach dotyczących komfortu cieplnego wymaga zwrócenia uwagi na przegrzewanie współczesnych budynków. W artykule zwrócono uwagę na korzystny wpływ pojemności cieplnej na ograniczenie dyskomfortu cieplnego we wnętrzu budynku. Analizowany w artykule efekt to tylko jeden z aspektów biernej ochrony budynku przed nadmiernymi wahaniami temperatury we wnętrzu. W dobrym projektowaniu należy wykorzystać wszystkie możliwe środki ochrony.
EN
Reduction of energy consumption by the energy efficient buildings and at the same time high expectations regarding thermal comfort require special attention paid to overheating. This article emphasizes the beneficial influence of thermal capacity to reduce thermal discomfort inside the building. Analyzed in this article effect is just one aspect of a passive building protection against excessive temperature fluctuations in the interior. In a good design all the possible means of protection should be used.
EN
The paper presents comparison of results of impulse response spectral analysis that has been obtained using a method based on cross-correlation with results obtained using classical FFT. The presented non-Fourier method is achieved by correlating the analyzed signal and reference single-harmonic signals and using Hilbert transform to obtain an envelope of cross-correlation. The envelope of cross correlation makes it possible to calculate appropriate indicator and make its plot in frequency domain as a spectrum. The spectrum obtained this way has its advantage over the FFT that the spectral resolution does not depend on duration of signal. At the same time, the spectral resolution can be much greater than spectral resolution resultant from FFT. Obtained results show that presented non-Fourier method gives frequency readout more accurate in comparison to FFT when the impulse response is a short-time signal e.g. few dozen of miliseconds lasting.
17
PL
Celem pracy jest przedstawienie sposobu obliczania oddziaływania temperaturą według normy PN-EN 1991-1-5:2005 „Eurokod 1, Oddziaływanie na konstrukcję, Część 1-5: Oddziaływanie ogólne, oddziaływanie termiczne”. Przedstawiono uszkodzenia płyt obudowy ściennej spowodowane działaniem temperatury. Podano wartości składowej równomiernej temperatury oraz wartość wydłużenia liniowego płyty. Spróbowano odnieść się do przyczyn powstania uszkodzeń oraz przedstawiono sposób naprawy.
EN
Presentation of manner of scaling of interaction is purpose of work according to norm temperature „ eurocode 1 PN-EN 1991-1-5:2005, interaction on construction, part 1-5 general interaction, thermal interaction ”. It present damages of plates of wall casings cause operation of temperature. Value of stretch of linear plate serve values of warehouse even temperatures and value of stretch of linear plate . For reasons of revolts of damages try to concern and manner of repair present.
EN
A new approach for frequency analysis of recorded signals and readout the frequency of harmonics is presented in the paper. The main purpose has been achieved by the cross$correlation function and Hilbert transform. Using the method presented in the paper, there is another possibility to observe and finally to identify single harmonic apart from commonly used Fourier transform. Identification of the harmonic is based on the effect of a straight line of the envelope of the cross$correlation function when reference and signal harmon$ ic have the same frequency. This particular case is the basis for pointing the value of the frequency of harmonic component detected.
19
Content available remote Structural physical problems research of industrial production hall buildings
EN
Research of the structural and physical problems of envelope structures and physical components of internal environment and their mutual interaction in industrial buildings mostly of a hall type is the subject of the investigation of this article. The research was solved in close touch with the grant projects VEGA 1/9023/02 "The Interaction of physical factors in the creation of an appropriate working environment" and 1/2562/05 "Evaluation of thermal, humidity and lighting conditions of the production industrial buildings" joining with the research project 1/0695/08 with the title "Thermal flows in interaction of building construction and underground as well as external outdoor conditions for large space hall buildings", supported by Slovak Fund for Scientific Research, task which is being presently elaborated.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.