Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  energy gain
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents statistical analysis of measurement results of electrical parameters for photovoltaic modules installed in stationary and dual-axis configurations. The parameters which were taken into account included: coefficient of variation, skewness and standard deviation. Also a correlation was determined between independent variables such as insolation, sunshine duration, cloudiness, ambient temperature and atmospheric pressure, and the dependent variable in the form of the daily electricity from photovoltaic conversion. In order to determine the repeatability of electricity waveforms occurring between summer months as well as between summer and winter months, the non-parametric U Mann-Whitney test was used. In order to analyse the repeatability of daily peak hours in which the highest value of the hourly electricity production is observed, the non-parametric Kruskal-Wallis test was used. The tested systems were connected to the power grid and operated independently. Test stands consisting of polycrystalline photovoltaic modules, single-phase on-grid inverters, irradiance sensors and a temperature recorder, were located on the building rooftop of the Faculty of Control Robotics and Electrical Engineering of the Poznan University of Technology in Poland (Central Poland, 52°24.4152′N, 16°55.7958′E) at the height of 30 metres above the ground level. A significant increase in the production of electricity using the PV module spatial positioning system was demonstrated in relation to modules based on the year-round modified design.
2
Content available remote Fotowoltaiczne systemy zintegrowane z budynkiem
PL
Fotowoltaiczne systemy zintegrowane z budynkiem( BIPV) są ciągle jeszcze rozwiązaniem niszowym w stosunku do systemów addytywnych (BAPV). Postęp techniczny i spadek cen przyczyniają się do ich rozpowszechnienia jako integralnych elementów przegród zewnętrznych, otwierając nowe możliwości architektonicznego kształtowania budynków. W artykule przedstawiono możliwości wykorzystania i perspektywy rozwoju BIPV oraz ich klasyfikację, wymagania projektowe i ograniczenia oraz uwarunkowania ekonomiczne. Na podstawie modelowego projektu domu jednorodzinnego zbadany został potencjał ekonomiczny i energetyczny stosowania BIPV w warunkach polskich i wskazano szanse rozwoju.
EN
The Building-Integrated Photovoltaics (BIPV) is still a niche solution compared to the Building Applied Photovoltaics BAPV. Technological progress and price decline contribute to spreading of the BIPV as integral elements of the buildings outer skin, opening new possibilities in the architectural design. The application and development possibilities of BIPV are presented, the common solutions are classified, the planning-related requirements and limitations are discussed and the economic circumstances are analysed. Based on a pilot project of a passive house, the energetic and economic potential of the implementation of the BIPV in Poland are examined and the future aspects are demonstrated.
3
Content available remote Technical and economic aspects of photovoltaic conversion of Southern Poland
EN
The article presents the results of a 13-year tests and analysis of performance and energy and electrical charge yield for typical photovoltaic modules made of different absorbers. Modules were installed on the south wall of Opole University building (at kard. B. Kominka Street). Registered in this period (2001-2013) values energy and charge of tested modules are presented in reference to 1 Wp their nominal power and to 1 m2 of PV modules. Their annual and monthly distributions, with particular emphasis on the seasonal changes of its parameters and phenomena of aging and degradation of the PV modules structure were shown. In the final part of the article was presented an economic analysis of the profitability of investment in 20 kWp grid connected PV system with and without implemented the program to support investment in renewable energy, which respect to the newly implemented in Poland Act on RES.
PL
W artykule przedstawiono wyniki 13-letniej analizy testowania sprawności oraz uzysku energii i ładunku elektrycznego typowych modułów fotowoltaicznych wykonanych z różnych absorberów, zainstalowanych na południowej ścianie budynku Uniwersytetu Opolskiego przy ulicy kard. B. Kominka. Zarejestrowane w tym okresie (2001-2013) wartości kumulacji energii i ładunku testowanych modułów przedstawiono zarówno w odniesieniu do 1 Wp ich mocy nominalnej, jak i do 1 m2 powierzchni modułów PV. Przedstawiono ich roczne i miesięczne rozkłady ze szczególnym uwzględnieniem sezonowości zmian ich parametrów oraz zjawiska starzenia i degradacji struktury modułów PV. W końcowej części artykułu zaprezentowano ekonomiczną analizę opłacalności 20 kWp inwestycji PV typu Grid Connected bez i z wdrożonym programem wsparcia inwestycji w OZE, tj. uwzględniające zapisy nowo wdrażanej w Polsce Ustawy o OZE.
PL
W pracy zamieszczono sposób przystosowania konstrukcji ekonomicznego systemu przekryć hal „Zachód” do funkcji energoaktywnego pozyskiwania energii cieplnej z promieniowania słonecznego. Pokazano sposoby pozyskiwania, transportu i magazynowania energii cieplnej za pośrednictwem powietrza. Podano koncepcje zabezpieczania konstrukcji przed przegrzewaniem oraz kompensacji przemieszczeń termicznych.
EN
The article presents the method for adaptation of the economic roof covering system used in “Zachód” halls to heat energy extraction from solar radiation. The discussion includes the ways of heat energy extraction, transport and storage as well as the concepts of securing the structure against overheating and thermal displacements.
5
Content available remote Algorytm optymalizujący uzysk energii w stacjonarnych farmach fotowoltaicznych
PL
Zwiększenie efektywności uzysku energii użytecznej z konwersji fotowoltaicznej można uzyskać poprzez podwyższanie sprawności ogniw fotowoltaicznych (PV), ale także poprzez optymalne konfigurowanie ekspozycji energii słonecznej na powierzchnię paneli słonecznych. Najefektowniejszym rozwiązaniem jest stosowanie systemów nadążnych za ruchami pozornymi Słońca, jednakże konstrukcje takich systemów są dość drogie, a ich nawigacja wymaga dodatkowych nakładów energii. Systemy stacjonarne natomiast wymagają doboru takiego usytuowania powierzchni paneli fotowoltaicznych, który w skali całego roku pozwoli wygenerować maksymalną energię przy zadanej lokalizacji. Niniejsza praca poświęcona jest opracowaniu algorytmu, pozwalającego optymalizować uzysk energii elektrycznej z konwersji energii Słońca dla zadanych warunków geograficznych i klimatycznych.
EN
Increasing the efficiency of the useful energy yield from the photovoltaic conversion can be obtained by improving the photovoltaic cells efficiency, but also through the optimal configuration of solar exposure to the surface of solar panels. The most effective solution is using the follow up system together with the apparent motion of the Sun. Constructions of these kinds of systems, however, are quite expensive, and their navigation requires extra energy. Stationary systems, on the other hand, require the selection of such a location of photovoltaic panels’ surface, which during the whole year, will generate maximum power at a given location. This paper is devoted to the algorithm development, allowing to optimize the yield of electricity from solar energy conversion for given geographical and climate conditions.
PL
Przedstawiono korzyści wynikające z zastosowania układów nadążnych ze śledzeniem Słońca w instalacjach fotowoltaicznych.
EN
The paper presents advantages resulting from using follow-up systems with Sun tracking in photovoltaic installations.
7
Content available remote Heating fluid in a FEC metal-foam tilled channel
EN
The results of experimental studies on heat transfer in air and water flow through the channel filled with metal foam alloy of FeCrAlY (FEC) were presented. The impact of foam on the intensity of heat exchange between the heated wall and the fluid was described. The differences in the efficiency of heating the gas and liquids through the metal foam were shown. During the air flow, filling the channel allows to heat the fluid to a clearly greater extent than in the channel without filling, and increase in the efficiency of heating compensates for the increased energy inputs on pumping the air. During the liquid flow, the presence of foam helps to reduce the wall temperature.
8
Content available remote Możliwość pozyskania energii cieplnej z samochodu osobowego w garażu
PL
Kwestie zmnleJszema zużycia energii stanowią obecnie obszar, wokół którego skupia się większość prac badawczych i ich technicznych aplikacji. W pracy przedstawiono możliwości pozyskania energii z garażowanego samochodu osobowego, jej rozkład jakościowy i ilościowy oraz trudności w wykorzystaniu tego typu ciepła. Dokonano analizy wynikającej z transformacji odebranego ciepła na potrzeby przygotowania ciepłej wody w domu jednorodzinnym oraz technicznego aspektu wynikającego z konieczności jego magazynowania. Wykonano uproszczoną analizę czasu zwrotu kosztów, związaną z wykorzystaniem ciepła z zastosowaniem tego typu źródła energii.
EN
Analysis of taken heat and its transformation to hot water in semidetached house has been presented. The technical problem of that heat storage has also taken into consideration. Some interesting practical possibility of application of heat from garaged car has discussed and as well as simple payback time (SPBT) for selected installation.
PL
Dotychczasowe badania metod wykorzystania energii słonecznej w budownictwie pozostawiły spuściznę w postaci teorii i praktyki stanowiącej podwaliny współczesnych realizacji i wytyczającej kierunki kolejnych badań. Kontynuowane są rozpoczęte w poprzednich dziesięcioleciach poszukiwania, a rozwiązania wykorzystujące energię słoneczną doskonale dzięki dostępności nowych technologii i materiałów. przedstawione obecnie koncepcje dotyczą kształtowania pojedynczych domów, zespołów budynków, a nawet całych słonecznych miast z uwzględnieniem wymogów ekologii, ekonomii oraz funkcjonalności i estetyki.
EN
The idea of solar house is not a contemporary one, it is been developing from the beginning of the history of architecture. Sun was used is housing design by every civilization all over the world, matching its usage to local climate, environment and tradition. Past experiments with solar systems left a heritage in theory and practice, which constitutes a foundation of modern solar architecture design and sets the direction of further development.
PL
W artykule przedstawiono wyniki badań eksperymentalnych związanych z określeniem wydajności i mocy innowacyjnych powietrznych kolektorów słonecznych konstrukcji autora. Zaprezentowano budowę stanowiska doświadczalnego oraz metodologię prowadzenia badań. Doświadczenia prowadzono dla różnych temperatur powietrza zasilającego oraz różnych natężeń przepływu tak aby w miarę dokładnie odwzorować warunki w jakich kolektor będzie eksploatowany w rzeczywistej instalacji suszarniczej. Wyniki zaprezentowano w formie wykresów zależności mocy pojedynczego kolektora oraz baterii dwóch szeregowo połączonych kolektorów od zmieniających się parametrów przepływu i temperatury. Na bazie zmierzonych parametrów wyznaczono drogą obliczeniowa moc pojedynczego kolektora oraz sezonowy uzysk energetyczny baterii kolektorów w typowej instalacji suszarniczej.
EN
The article presents the results of experimental scientific research connected with the determination of the efficiency as well as power of innovative air solar collectors constructed by the author. The construction of experimental stand as well as research methodology have been presented. The research was performed for different feeding air temperatures and various flow intensity in such a way as to copy the conditions in which it will be exploited in the drying installation, as precisely as possible. The results have been presented in the form of diagram showing the relation between the power of a single collector as well as battery of two serially connected collectors with the changing flow and temperature parameters. On the base of the measured parameters the calculation of power of a single collector as well as the seasonal energetic yield of collectors’ battery in the typical drying installation have been determined.
11
PL
Przedstawiono wyniki badań dotyczących wpływu zmienności promieniowania słonecznego na zużycie energii cieplnej w szklarni. Podstawą analiz były badania wykonane w szklarni eksploatowanej całorocznie. Celem tych badań było określenie wielkości zużycia energii cieplnej w okresie funkcjonowania szklarni bez ekranu termoizolacyjnego w zależności od współczynnika zmienności całkowitego promieniowania słonecznego.
EN
The paper presents the result of studies on the effect of variation of solar radiation on thermal energy consumption in greenhouse. The basis of research studies have been done in the greenhouse operated year-round. The aim of this study was to determine the size of thermal energy consumption during operation of the greenhouse without screen insulating depending on the coefficient of variation of total solar radiation.
PL
W oparciu o wyprowadzone modele procesu wzbogacania kopalnianego powietrza wentylacyjnego w metan metodą adsorpcji zmiennociśnieniowej i separacji membranowej dokonano analizy kosztów zatężania dla szerokiego zakresu parametrów ruchowych. Dla dwukrotnego wzbogacenia mieszanki gazowej w metan (i porównywalnych wydajności) koszty całkowite procesu membranowego są o kilkadziesiąt procent wyższe od kosztów zatężania metodą PSA. Oszacowano zysk energetyczny, wynikający z intensyfikacji produkcji ciepła w reaktorze katalitycznym z rewersją przepływu.
EN
Based on the models derived for the enrichment of mine ventilation air in methane via pressure swing adsorption (PSA) or, alternatively, membrane separation, total annual costs are analysed for a wide range of the operating parameters. For a twofold increase in CH4 concentration the cost of the membrane separation is by several percent higher than that of the PSA process. Also, the profit is assessed due to an increased heat production in a catalytic flow reversal reactor (CFRR).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.