Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  energia pochłonięta
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article presents the structure influence of distance spacer fabric on the ability to protect against impact based on impact test results of selected packages made of spacer fabrics. The aim of testing these materials was to check their ability to suppress the impact force and absorb the energy in anti-impact vests. The purpose of using these textile materials in protective clothing would be to reduce the weight of the final product, and thus also to reduce heat stress during use. The article contains test results of the force received under an anvil and of the energy absorbed for each of the packages tested. The textile package developed, consisting of three layers, was classified as a protective material because it meets the requirements of EN 13158:2018 Protective clothing – Protective jackets, body and shoulder protectors for equestrian activities. The package provides protection at Level 1, the force received under an anvil during tests was 1.55 kN, and the package absorbed 24.96% of all impact energy. Additionally, the selected package was tested for air permeability.
PL
W artykule przedstawiony został eksperyment doboru optymalnego tekstylnego pakietu antyuderzeniowego, w celu wykorzystania go w odzieży ochronnej. Zastosowanie tekstylnych materiałów ma na celu obniżenie wagi wyrobu końcowego, aby zminimalizować stres cieplny występujący podczas użytkowania. Artykuł zawiera testy udarowe, które zostały podzielone na trzy etapy, każdy zawiera cel, wyniki oraz podsumowanie etapu. Opracowany pakiet tekstylny z dzianin dystansowych pochłania energię uderzenia i redukuje odebraną siłę uderzenia. Odzież (kamizelka), która mogłaby zawierać ten pakiet będzie o około 1,5 kg lżejsza od typowych obecnie dostępnych na rynku kamizelek. Wybrany pakiet spełnia wymogi normy PN-EN 13158:2010 na poziomie 1.
PL
Badano inicjowanie spłonek elektrycznych impulsami o stałej energii i 3 poziomach mocy: P ~1 W, P ~1 kW do P ~1 MW. Porównywano działanie spłonek z mostkiem metalicznym połączonych z zapłonnikiem (SI), pobudzanych ze stałą energią dysponowaną ok. 20 mJ i spłonek z rezystancją rozłożoną w mieszaninie pirotechnicznej (SII), pobudzanych ze stałą energią dysponowaną ok. 200 mJ. Zobrazowano kilkukrotne „podimpulsy” prądowe prowadzące do jednego pobudzenia SII. Średnie opóźnienie zadziałania malało od 8,7 ms przy P ~1 W do 133 µs przy P ~1 MW dla SI oraz od ok. 90 µs przy P ~1 kW do ok. 50 µs przy P ~1 MW dla SII, przy czym od P ~1 kW dla obu rodzajów spłonek praktycznie nie zmieniało się. Przedyskutowano mechanizmy pobudzenia i czynniki wpływające na mierzone opóźnienia. Wyznaczono średnie energie pochłonięte do chwili zadziałania: 5-7 mJ dla SI, ok. 15 mJ dla SII. Oszacowano końcowe ciśnienia: 300-400 bar w korpusach spłonek/zapłonników.
EN
Initiation of electric primers by pulses of constant energy at 3 different levels of power from P ~1 W to P ~1 MW was investigated. Actions of primers with metallic electric bridge (SI) connected to an exploder and initiated by permanent disposable energy of ca. 20 mJ were compared to primers with the resistance distributed within a pyrotechnic mixture (SII) initiated by permanent disposable energy of ca. 200 mJ. A series of current “sub-pulses” at one activation of SII is shown. Average delay of activation was reduced from 8.7 ms at P ~1 W to 133 mikro s at P ~1 MW for SI, and from ca. 90 mikro s at P ~1 kW to ca. 50 mikro s at P ~1 MW for SII, to be in practice unchangeable above P ~1 kW for two types of primers. Mechanisms of initiation and factors influencing the measured delays were discussed. Average energies absorbed to the moment of activation were determined: 5-7 mJ for SI, and ca.15 mJ for SII. Final pressures inside the casing of primers/igniters were estimated on the level of 300-400 bar.
3
Content available Pomiary parametrów spłonek uderzeniowych
PL
Przedstawiono wyniki badań średniej energii pobudzenia (ok. 130 mJ), jej odchylenia standardowego (ok. 30 mJ), zwłoki czasowej (średnio 450 µs), zagłębienia iglicy (średnio 350 µm) i energii pochłoniętej (< 150 mJ) do chwili inicjacji – na przykładzie spłonki KWM-3. Pomiary prowadzono za pomocą układu i metod opracowanych w Instytucie Technicznym Wojsk Lotniczych (ITWL). Pokazano zmianę zwłoki czasowej, zagłębienia iglicy i energii pochłoniętej w funkcji energii użytej do pobudzenia.
EN
Investigation results of percussion cap (KWM-3 as example) parameters such as initiation mean energy (130 mJ approx.), their standard deviation (30 mJ approx.) as well as delay time (450 µs at an average), firing pin deepening (350 µm at an average) and energy absorbed (< 150 mJ) up to the initiation moment were presented. The measurements were conducted with an aid of the facility and methods worked out in the AFIT (ITWL). The change of delay time, firing pin deepening and energy absorbed versus energy used for initiation were shown.
PL
Wyniki uzyskane na urządzeniu opisanym w pracy zinterpretowano za pomocą modelu numerycznego. Uzyskano zgodność przebiegów zwłoki czasowej (400-100 μs), zagłębienia wgniatanej iglicy (ok. 360 μm) i energii pochłoniętej do chwili zadziałania spłonki (ok. 160 mJ) w funkcji energii dysponowanej uderzaka (200-1500 mJ) - obliczonych w ramach modelu i wyznaczonych na podstawie danych doświadczalnych. Rozbieżności wartości energii wyznaczanej za pomocą akcelerometru związanego z uderzakiem i pochłanianej w materiale spłonki (metalu i materiale pirotechnicznym) w danym układzie mechanicznym zależą od zwłoki czasowej. Energia zużyta na pobudzenie materiału pirotechnicznego (ok. 3,3 mJ) jest dużo mniejsza od całkowitej energii pochłoniętej.
EN
Results obtained on the device described in were interpreted by means of the numerical model. A conformity of the model and experimentally based profiles of delay time (400-100 μs), firing pin immersing (360 μm approx.) and the absorbed energy (160 mJ approx.) up to the moment of percussion cap igniting versus the striking mass energy (200-1500 mJ) was obtained. A discrepancy of the energy values that determined with an aid of accelerometer mounted on the striking mass and that absorbed in the cap material (metal and pyrotechnic substance) depends on the delay time in a given mechanical system. The energy utilized to ignite a pyrotechnic material (3.3 mJ approx.) is much smaller then the total absorbed energy.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.